PROGRAMMING INSTRUCTIONS
The above picture shows front dispensing panel for the
Waterlogic WL400
.
Press and Hold all 4 dispensing buttons for 10 seconds.
There are 5 options in the menu.
Cold Button cycles down the menu
Room (Ambient) Button cycles up the menu
Hot Button Selects the Option
Extra Hot Button Exits the menu
Settings
Programming
F-S Filter Setting
Filter Setting can be adjusted between 1,000 to 9,000
gallons in 1,000 increments.
F-r Filter Resetting
Choices are Yes or No
C-S Cold Temperature Setting
Temperature Setting can be adjusted from 2.8°C to 12.2°C
(37°F to 54°F)
H-S Hot Temperature Setting
Temperature Setting can be adjusted from 70°C to 95°C
(158°F to 203°F)
S-S Sleep Mode
Choices are 3 Hour, 6 Hour, 12 Hour or No (Off)