WL400
Manual Page 84
–
Revision: 10-23-2019
RESETTING THE HOT TANK OVERLOADS OR HIGH LIMIT SAFETY
1.
Turn off Green Heater/Compressor Switch on rear of unit.
O=OFF
2.
Unplug the Power Cord from rear of unit.
3.
Remove the Tower Cover Locking Screws and Slide
Locks towards outside of unit to unlock both locks.
4.
Slide Top Cover forward and lift in front of top cover to open.
5.
Remove the 2 Phillips Screws from Left Side Panel (when standing
behind unit) and remove side panel.
6.
Check and press both Thermal Overload buttons on Hot Tank.
7.
Close, lock and replace Top Cover Screws
8.
Turn on Red Power Switch and Green Heater / Compressor
Switch.
I=ON
Remove Two Screws
Slide Locks Open
Содержание WL400 Base Cabinet
Страница 34: ...WL400 Manual Page 34 Revision 10 23 2019 WL400 BASE MAIN PARTS DRAWING AND PARTS LIST...
Страница 42: ...WL400 Manual Page 42 Revision 10 23 2019 BASE CABINET SIDE REMOVAL...
Страница 43: ...WL400 Manual Page 43 Revision 10 23 2019 BASE CABINET CONFIGURATION...
Страница 45: ...WL400 Manual Page 45 Revision 10 23 2019 INSIDE LEFT SIDE CABINET CONFIGURATION...
Страница 46: ...WL400 Manual Page 46 Revision 10 23 2019 INSIDE RIGHT SIDE CABINET CONFIGURATION...
Страница 48: ...WL400 Manual Page 48 Revision 10 23 2019 OLD RO Membrane 10 8060 Installed NEW RO Membrane 10 8061 Installed...