1.
Unpack the
Waterlogic WL400
Water Treatment System
and check
exterior for damage.
2.
Remove Front Panel from Base Cabinet opening Top of Panel and
Removing Slide Bar.
3.
Remove
WL400
Water Treatment System
from packaging and place on
top of base cabinet.
4.
Attach
WL400
Water Treatment System
to base cabinet with Locking
Bolt provided.
a)
Remove screws from locking slides located under Front Cover
adjacent to faucet.
b)
Unlock slides and open Top Cover of
WL400 Water Treatment
System
.
c)
Pull cover forward and lift from the front to open top cover.
d)
Locate wires and run them through.
5.
Connect Wires (Quick Connect Clips) on back of unit from Base Cabinet to
WL400
.
6.
Remove Pre-Carbon and Post-Carbon Filters and flush 5 gallons of water through each filter
separately.
7.
Reinstall Pre and Post Carbon Filters.
8.
Close RO Bypass and Bladder Tank
9.
On Back of Cabinet, connect 2 pieces of Tubing to RO
Drain Line and Water Out Line and run to external drain.
10.
Connect the power lead and insert it into the rear of the machine. Turn on
the Red Power Switch
I=ON
. Do NOT turn on the Green Heater /
Compressor Switch.
CAUTION!
NEVER TURN ON HEATER BEFORE FILLING HOT TANK.
Remove Two Screws
Slide Locks Open
Содержание WL400 Base Cabinet
Страница 34: ...WL400 Manual Page 34 Revision 10 23 2019 WL400 BASE MAIN PARTS DRAWING AND PARTS LIST...
Страница 42: ...WL400 Manual Page 42 Revision 10 23 2019 BASE CABINET SIDE REMOVAL...
Страница 43: ...WL400 Manual Page 43 Revision 10 23 2019 BASE CABINET CONFIGURATION...
Страница 45: ...WL400 Manual Page 45 Revision 10 23 2019 INSIDE LEFT SIDE CABINET CONFIGURATION...
Страница 46: ...WL400 Manual Page 46 Revision 10 23 2019 INSIDE RIGHT SIDE CABINET CONFIGURATION...
Страница 48: ...WL400 Manual Page 48 Revision 10 23 2019 OLD RO Membrane 10 8060 Installed NEW RO Membrane 10 8061 Installed...