WL3000 Technical Manual - May 2014
Environmental Information
Refrigeration Gas Information
Note: This information is provided as guidance only. Energy consumption will be
effected by incoming water temperature, room - temperature and usage patterns.
Figures in brackets apply when Sleep Mode is turned on.
DESCRIPTION
SINGLE TANK DOUBLE TANK SINGLE TANK DOUBLE TANK
WLMHC3000 WLMHCS3000
WLMC3000
WLMCS3000
Width Depth Height
500mmW x 515mmD x 535mmH
Water Connection
Diameter 1/4” Hose
Cold Water Temp
3 - 12° (23 - 54°F) Adjustable
Hot Water Temp
70-97° (158 - 207°F) Adjustable
N/A
N/A
Weight
29kg
33kg
27kg
31kg
Power Supply
230Volt / 50Hz
Control & Unit
1.1 Amp
1.1 Amp
1.1 Amp
1.1 Amp
Heater
6.1 Amp
6.1 Amp
N/A
N/A
Refrigeration Gas
Please refer to specification label at rear of machine
Min/Max Water
Pressure
2/3.5
2/3.5
2/3.5
2/3.5
Recommended
Water Pressure
3 Bar
3 Bar
3 Bar
3 Bar
PRODUCT/MODEL
DESCRIPTION
ENERGY
COMSUMPTION IN
NORMAL OPERATION
MAXIMUM NOISE
LEVEL
Hot, Cold and Sparkling
2.59 (2.21) KwH
14 dB
Hot and Cold
2.47 (2.11) KwH
14 dB
Cold and Ambient
1.2 KwH
0.9 dB
Cold and Sparkling
1.32 KwH
10 dB
Cold Only
1.2 KwH
0.9 dB
MODEL
g (±2)
OZ (±0.07)
COLD TANK
WL-3000
72
2.54
WL-3000 single tank
WL-3000Max
75
2.65
WL-3000 Double tank
WL-3000Sparkling
95
3.35
End of Life
Non Eu Countries
At the end of this products life, please ensure that it is disposed of in an
environmentally friendly manner which is in line with your Country requirements/
guidelines.
WEEE (EU ONLY)
Please be aware that our products are covered by the Waste Electrical and Electronic
(WEEE) directive (2002/96/EC). The symbol shown above denotes that the product
should not be disposed of with general/household waste. Please contact your sup-
plier/service agent who will arrange for the collection and disposal of this product.