background image

 

WL270

 

Manual

 

                                                                    

Page

 

20

 

 

Revision

 

2

2

2017

 

 

No

 

WLCP

 

Part

 

No.

 

Description

 

Part

 

No

 

Stocked?

 

 

1

 

19

5005

 

Black

 

Top

 

Cover

  

PL

1254

 

Yes

 

 

19

1033

 

Blue

 

Top

 

Cover

 

PL

1254

A

 

Yes

 

 

2

 

19

1038

 

Reservoir

 

Cover

 

PL

1259

 

Yes

 

 

3

 

19

1019

 

Side

 

Panel

 

Silver

  

ST

8212

 

Yes

 

 

4

 

19

1034

 

Top

 

Front

 

Panel

 

for

 

Drip

 

Tray

  

*Request

 

to

 

be

 

shipped

 

with

 

Hot

 

Water

 

Safety

 

Sticker

 

 

P/N

 

LP

7169

 

WLCP

 

PN

 

12

0001

 

PL

1255

 

Yes

 

 

4.1

 

12

0001

 

Hot

 

Water

 

Safety

 

Sticker

 

LP

7169

 

Yes

 

 

5

 

19

5010

 

Black

 

Top

 

Front

 

Insert

 

Panel

 

PL

1257

 

Yes

 

 

19

1036

 

Blue

 

Top

 

Insert

 

Panel

 

PL

1257

A

 

Yes

 

 

5.1

 

19

1014

 

Front

 

Panel

 

Display

 

Sticker

 

LP

7180

 

Yes

 

 

6

 

19

2025

 

Black

 

Drip

 

Tray

 

Grill

 

PL

1270

 

Yes

 

 

19

1048

 

Blue

 

Drip

 

Tray

 

Grill

 

PL

1270

A

 

Yes

 

 

7

 

19

2020

 

Black

 

Drip

 

Tray

 

Body

 

PL

1289

B

 

Yes

 

 

Содержание WL270

Страница 1: ...LTRAVIOLET RADIATION Protect your skin and eyes against ultraviolet rays Never look directly at an operating UV light Disconnect before removing UV Lamp CAUTION UV LAMPS ARE HAZARDOUS Lamps are consid...

Страница 2: ...nk per instructions in the pre installation procedures 7 Clean and sanitize external surfaces of the unit Use soap and water or chemicals that are compatible with ABS plastic and will not damage or de...

Страница 3: ...19 1052 Replacement parts can be obtained from Waterlogic or an Authorized Waterlogic Dealer See Parts Layouts Drawings and Lists for additional repair parts Hot Tank Service Hot Tanks with controls m...

Страница 4: ...chemicals Refer to Material Safety Data Sheet for specific requirements of each product CAUTION STAINLESS STEEL TANK DESCALING The Hot Tank is made from stainless steel Ensure descaling solution is co...

Страница 5: ...ditions 15 Flush unit until all descaler is removed WARNING HOT WATER HAZARD Unit Produces Very Hot Water and Steam Always use insulated and chemically compatible containers and let unit cool down bef...

Страница 6: ...Red Heater and Compressor Power Switch O OFF on rear of unit 2 Unplug the Power Cord from rear of unit 3 Remove 4 Phillip Screws from the Access Panel on rear of unit and Lower Access Panel 4 Locate p...

Страница 7: ...the hot and cold tanks are filled with water BEFORE turning on the Red Heater and Compressor Power Switch CAUTION NEVER TURN ON HEATER BEFORE FILLING HOT TANK Red Heater and Compressor Power Switch mu...

Страница 8: ...WL270 Manual Page 19 Revision 2 2 2017 WL270 DRAWINGS AND PARTS LISTS...

Страница 9: ...p Front Panel for Drip Tray Request to be shipped with Hot Water Safety Sticker P N LP 7169 WLCP PN 12 0001 PL 1255 Yes 4 1 12 0001 Hot Water Safety Sticker LP 7169 Yes 5 19 5010 Black Top Front Inser...

Страница 10: ...Yes 10 19 1049 Leak Tray PL 1292 Yes 11 19 1021 Side Panel Bracket ST 8229 Yes 12 12 1602 Bottom Shelf ST 8035 Yes 13 10 2200 Compressor R134a 1 8HP 120V 60Hz CO 9001 A Yes 13 1 10 5018 Compressor Ov...

Страница 11: ...in valve body only for 5 16 CT 2031 A Yes 17 3 NA Drain valve nut only for 1 4 and 5 16 CT 2082 No 17 4 19 1049 Rubber O Ring for Drain Hole PL 1293 Yes 17 5 NA Drain Valve Clamp 5 16 CT 2046 No 18 19...

Страница 12: ...6S PU 4104 Yes 26 19 1026 Cover of Inlet SV ST 8233 Yes 27 19 1000 Wire Condenser for Gravity Fed CO 9040 No 28 1 10 3010 UV Lamp Ballast 110V 60Hz EL 5006 A CN Yes 28 2 19 1006 Ballast Wire EL 5076 Y...

Страница 13: ...6 Cold Thermostat cover Label LP 0326 L00 00 Yes 34 19 1017 Silver Back Panel ST 8210 Yes 12 1210 UV Lamp Retaining Threaded Nut PL 1128 Yes 36 10 2350 UV Lamp 8W Assembly CT 2083 Yes 36 1 19 1074 Wir...

Страница 14: ...s 42 1 19 1079 Overload with Manual reset 95 C 203 F HT 3035 Yes 42 2 19 1078 Hot Tank Thermostat 83 C 181 F HT 3034 Yes 42 3 12 6900 Thermostat and Overload Metal Cover ST 8289 Yes 42 4 19 2065 Hot T...

Страница 15: ...3 Gallons PL 1258 Yes 50 19 1042 Mechanical Push Button for Ambient Green PL 1264 Yes 51 19 1041 Mechanical Push Button for Cold PL 1263 Yes 52 19 1040 Push Button for Hot Right Red PL 1262 Yes 53 19...

Страница 16: ...Harness Assembly EL 5079 Yes Not Shown 10 3062 JG LLDPE Tube Blue 8mm John Guest P N PE 0806 100M B PU 4014 A Yes Not Shown Purchase from John Guest JG LLD PE Tube Blue O D 1 4 John Guest P N PE 08 BI...

Страница 17: ...WL270 Manual Page 28 Revision 2 2 2017 WL270 WATER FLOW DIAGRAM Storage 11 6 L Leak Detection Sensor...

Страница 18: ...kwise lowers the set point temperature and the range is approximately 20 F thru the full range of adjustment 7 00 to the 5 00 positions You should be able to turn the screw from the factory set point...

Страница 19: ...nual Page 30 Revision 2 2 2017 WL270 ELECTRICAL DIAGRAM DANGER HIGH VOLTAGE ELECTRICAL HAZARD PCB Printed Circuit Board contains High Voltage Only trained and qualified technicians should attempt live...

Отзывы: