10.

 

Dispenses Hot and Cold Water at the Same Time 

 
 

Possible Reason 

Solution 

Too much water pressure.  
Recommend 40 to 60 psi for 

WL250

 

Water Treatment 

System

 to operate properly. 

Check water pressure at the inlet bulkhead with a water 
pressure gauge. 
 
Additional method of verification is to turn off water to unit 
and press the dispense button.  Does the solenoid open 
without water pressure to the unit?  Listen for solenoid to 
activate, not button “click”. 
 
Adjust water pressure to 40‐60 psi. 

Hot or Cold solenoid is stuck 
open. 

Remove Top cover.   
 
Check Hot Solenoid:  Dispense cold water and visually inspect 
tubing for water flow from both tanks. 
 
Check Cold Solenoid:  Disconnect elbow from outlet of cold 
solenoid.  Select hot water and dispense (quickly releasing 
dispensing button to avoid much water coming out of cold 
solenoid. 
 
Replace solenoid as necessary. 

 
 

 

Содержание WL250

Страница 1: ...ice Flow is 1 89 Liters 0 5 gallons per Minute 7 Hot Water Intermittently Forced Through the Faucet or a Dual Stream Out of the Faucet 8 Hot Water coming out of both the Faucet and the Vent Hole 9 Hot...

Страница 2: ...thod of verification is to turn off water to unit and press the dispense button Does the solenoid open without water pressure to the unit Listen for solenoid to activate not button click Adjust water...

Страница 3: ...the water supply valve The unit is not properly plugged into electrical outlet Check electrical outlet connection or for blown circuit breaker Red Heater and Compressor Switch on unit is in the off p...

Страница 4: ...nt Dispensing PCB or Solenoid Connector Check that they are connected properly and tightened Solenoid If both the Water Pressure and PCB have been ruled out then it is the Solenoid Replace Solenoid Di...

Страница 5: ...feed line Filters Filters with high pressure drop due to fouling or just by design Change filters more frequently or go to higher micron size filter for local water conditions Restrictions Flow path...

Страница 6: ...without water pressure to the unit Listen for solenoid to activate not button click Adjust water pressure to 40 60 psi Improper tubing attachment from the tank to faucet or vice versa Verify tubing is...

Страница 7: ...aucet The hot tank outlet tube has a restrictor in its base This ensures the reservoir is always full by allowing more water in than out There is a small hole in the side of the tank outlet tube that...

Страница 8: ...to unit and press the dispense button Does the solenoid open without water pressure to the unit Listen for solenoid to activate not button click Adjust water pressure to 40 60 psi Hot or Cold solenoi...

Страница 9: ...lity Red Heater and Compressor Switch on unit is off Turn Red Heater and Compressor Switch on I ON Loose connection s on the Display PCB Turn power off unplug the unit and visually inspect solenoid co...

Страница 10: ...has an outlet restrictor to ensure the tanks remain full of water and water is controlled as it is released to the faucet The inlet solenoid controls flow into the tanks The tanks will depressurize o...

Страница 11: ...EEL TANK DESCALING The Hot Tank is made from stainless steel Ensure descaling solution is compatible with stainless and always flush the unit completely Dispose in an environmentally safe manner Mater...

Страница 12: ...e WL250 Water Treatment System produces Hot Water up to 87 C 188 F Water above 52 C 125 F can cause severe burns or scalding Hot water should be dispensed carefully into insulated container to avoid i...

Отзывы: