Page 66 ‐ Revision: 12‐12‐2018
5.
Turn off water supply and remove sanitizing cartridge from inlet water supply. Reconnect
water supply to inlet fitting.
6.
Allow descaling solution to remain in the Hot Tank for 15 minutes (length of time may vary
depending on water conditions).
7.
Place a pitcher, catch basin or other container under the faucet of the
WL250
.
8.
Flush the Hot Tank until water runs clear.
9.
Once clear Water dispenses from the faucet the Hot Tank has been descaled. Always
ensure unit is performing to the customer’s satisfaction.
10.
Replace Filters.
WARNING!
HOT WATER.
The
WL250
Water Treatment System
produces Hot Water up
to 87°C (188°F).
Water above 52°C (125°F) can cause severe burns or scalding. Hot
water should be dispensed carefully into insulated container to avoid injury. Always use
insulated and chemically compatible containers and let unit cool down before draining
the Hot Tank to avoid injury.
CAUTION
!
MUST
REPLACE HOT TANK 3‐5 YEARS DEPENDING ON USAGE
. The Hot
Tank and its controls must be replaced a minimum of every three to five years depending
on usage to ensure efficient and dependable operation.
WARNING!
REINSTALL ALL PANELS AND COVERS.
Always reinstall all panels, protective
covers, and fasteners after servicing equipment. Failure to do so could result in severe
personal injury and will void the certifications and warranty of the equipment
.