9.

 

Hot Water Drip out of Faucet 

 

Possible Reason 

Solution 

Small Outlet Vent Hole susceptible to scale 
build up. 

Descale Tank.   
 

See Hot Tank Descaling Instructions that are included 
further below in this Troubleshooting Section. 

 
See instructional video on the Partner Area of the 
Waterlogic.com website for more information.

 

 

All 

Waterlogic

 Hot Tanks have a built in Vent or 

Expansion Chamber in the top of the tank except for 
WL270 (GF) units. 

 

The Vent Chamber allows for expansion of the water 
when it is heated. 

 

The chambers are separated by a welded‐in tank 
baffle. 

 

Water always flows into the bottom of the tank and 
out the top to the faucet. 

 

The hot tank outlet tube has a restrictor in its base.  
This ensures the reservoir is always full by allowing 
more water in than out. 
 
There is a small hole in the side of the tank outlet tube 
that allows air and water to pass into the vent 
chamber as it is heated. 
 
Water in the vent chamber is suctioned back through 
the outlet tube vent hole when water is dispensed. 

 

Expansion of water as it is heated in the reservoir will 
push the water out the faucet when the outlet tube 
vent hole becomes plugged with debris or scale.   

 

The small Outlet Vent Hole is susceptible to scale build 
up and is a key indicator that descaling is required. 

 

It is critical to descale the hot tank through the vent 
line and outlet line on a regular basis to prevent this 
problem. 

 

Descaling through the inlet and/or outlet lines only 
will not clean the vent chamber and outlet vent hole 
properly. 

Содержание WL250

Страница 1: ...ice Flow is 1 89 Liters 0 5 gallons per Minute 7 Hot Water Intermittently Forced Through the Faucet or a Dual Stream Out of the Faucet 8 Hot Water coming out of both the Faucet and the Vent Hole 9 Hot...

Страница 2: ...thod of verification is to turn off water to unit and press the dispense button Does the solenoid open without water pressure to the unit Listen for solenoid to activate not button click Adjust water...

Страница 3: ...the water supply valve The unit is not properly plugged into electrical outlet Check electrical outlet connection or for blown circuit breaker Red Heater and Compressor Switch on unit is in the off p...

Страница 4: ...nt Dispensing PCB or Solenoid Connector Check that they are connected properly and tightened Solenoid If both the Water Pressure and PCB have been ruled out then it is the Solenoid Replace Solenoid Di...

Страница 5: ...feed line Filters Filters with high pressure drop due to fouling or just by design Change filters more frequently or go to higher micron size filter for local water conditions Restrictions Flow path...

Страница 6: ...without water pressure to the unit Listen for solenoid to activate not button click Adjust water pressure to 40 60 psi Improper tubing attachment from the tank to faucet or vice versa Verify tubing is...

Страница 7: ...aucet The hot tank outlet tube has a restrictor in its base This ensures the reservoir is always full by allowing more water in than out There is a small hole in the side of the tank outlet tube that...

Страница 8: ...to unit and press the dispense button Does the solenoid open without water pressure to the unit Listen for solenoid to activate not button click Adjust water pressure to 40 60 psi Hot or Cold solenoi...

Страница 9: ...lity Red Heater and Compressor Switch on unit is off Turn Red Heater and Compressor Switch on I ON Loose connection s on the Display PCB Turn power off unplug the unit and visually inspect solenoid co...

Страница 10: ...has an outlet restrictor to ensure the tanks remain full of water and water is controlled as it is released to the faucet The inlet solenoid controls flow into the tanks The tanks will depressurize o...

Страница 11: ...EEL TANK DESCALING The Hot Tank is made from stainless steel Ensure descaling solution is compatible with stainless and always flush the unit completely Dispose in an environmentally safe manner Mater...

Страница 12: ...e WL250 Water Treatment System produces Hot Water up to 87 C 188 F Water above 52 C 125 F can cause severe burns or scalding Hot water should be dispensed carefully into insulated container to avoid i...

Отзывы: