background image

16

17

Waterlogic 2000IT Technical Manual - Issue B, December 2013

Maintenance and Servicing

6 MONTH SERVICE PROCEDURE

This procedure should only be carried out by persons trained by Waterlogic 

International or their approved distributors.

The following instructions cover models that can include Hot, Cold and Ambient.

• Every six months the filters and UV lamp must be changed.

• The quartz sleeve must be removed, checked and cleaned every six months if 

needed.

• A WL 2000IT with a hot water option may require having any calcium build up 

inside the hot tank removed, depending on local water conditions.

• No paperwork or cleaning records should ever be stored inside the WL 2000IT.

1. 

Isolate the power to the WL 2000IT by turning off the red switch and removing 

the power cord at the rear of the WL 2000IT.

2. 

To access the filters, undo the screws and release the clips located in front 

of the lower front panel and remove the panel to gain access to the interior of 

machine. To access the filters on a mini machine just remove the top cover. This is 

a high voltage area and the machine should be isolated from the power supply.

3.

 When a valved twist filter head is installed there is no need to turn off the water 

supply; the water is automatically isolated when you remove the filter.

4.

 To remove the Waterlogic filters, twist anti-clockwise and replace with a new 

Waterlogic twist filter, twist clockwise.

5.

Remove the Waterlogic UV lamp by unplugging the UV loom connector and 

pulling the lamp upwards.

6.

 Check the quartz sleeve for scale build up and clean if necessary.

7. 

Fit the Quartz sleeve back into the unit taking great care at this stage not to 

crack the Quartz.

8.

 Replace the UV lamp assembly and re-connect it. Do not touch the UV lamp 

with bare hands.

9.

  Inspect the electrical and water connections of the machine.

10.

 Check the air gap around the machine to ensure it is not blocked.

11.

 Turn on red switch, on the back of the machine.

12. 

Check that the UV lamp is alight by observing a blue glow from the top of the 

UV cap. Do not remove the lamp from holder whilst ignited and do not look into an 

ignited UV light.

13. 

Close the front of the machine and the top of the machine by fitting the panels 

back to their original position.

14.

 Flush 10 litres of hot water and 5 litres of cold water through the machine to 

ensure that the filters are generated and the water is running clear of any carbon 

fines.

15.

 Turn on the heater and compressor switch and allow the machine to cool and 

heat the water.

16

 Taste the water and check the machine is clean and functions to the customer’s 

satisfaction. If you are not satisfied with the quality of the water, flush 2 more litres 

of water through the machine

17.

 Wipe the outside surfaces (non-abrasive cleaner), clean the drip tray, check 

there is a 50mm air gap around the WL 2000IT.

18.

 Taste the water, ensure there are no carbon fines in the water, and check the 

WL 2000IT functions to the customer’s satisfaction. Should there be any taste 

issues or carbon fines still in the water then flush the WL 2000IT again.

SANITISING OR DE-SCALING

Please ensure that you do not accidentally drop sanitiser or de-scaler on any of 

the WL 2000IT’s water or electrical connections.

1. An empty filter housing, as used on the AMETEK filter system fitted with in and 

out pipe fittings, will be needed to mix the sanitizing solution. Flush the solution 

into the machine from the rear bulkhead. Sanitising the machine using this method 

will allow the whole cold water system from entry to exit to be sterilised, including 

the carbonation pump.

2.

 Mix a solution of sanitiser in the empty filter housing.

3.

 Turn off the water supply to the WL 2000IT, release the internal water pressure 

by momentarily pushing the cold water button. Disconnect the water feed pipe 

from the rear water in bulkhead of the machine.

4.

 Fit the water feed pipe to the inlet side of the filter housing with the sanitiser in. 

Connect a length of 1/4” inch water pipe from the outlet of the filter housing to the 

water ‘IN’ bulkhead at the rear of the machine.

Содержание WL2000IT

Страница 1: ...Waterlogic 2000IT Technical Manual Issue B December 2013 WL2000IT Technical Manual...

Страница 2: ...ns 14 Maintenance and Servicing 16 Sanitising or Descaling 17 Fault Finding 18 Technical Specifications and Warranties 20 End of Life 22 ROHS 22 BioCote 22 Main PCB Schematic Diagram Hot and Cold 24 W...

Страница 3: ...ating element The temperature of the Hot Tank is controlled by a thermostat and it is pre set at the factory at approximately 87 C A BI metal overload thermostat is fitted to stop the tank overheating...

Страница 4: ...circuit UV LAMP The UV light is an 8 watt germicidal lamp at a wavelength of 253 7 NM which is very efficient at destroying bacteria in water The UV lamp is immersed in the centre of cold tank and pr...

Страница 5: ...mately 10 litres through the hot tank first until the water runs clear of any carbon fines 7 Now flush water through the Cold Tank with approximately 10 litres 20 litres if cold only 8 Once you are su...

Страница 6: ...eal operating pressure is at 3 bar At pressures higher than 3 bar the machine will not function correctly and can lead to leaks 6 Please flush the water supply pipe until it runs clear before making t...

Страница 7: ...has a good taste If you detect a plastic taste then it is an indication that the machine needs to be flushed again 17 Check the machine to make sure it is electrically safe 18 The WL 2000IT should be...

Страница 8: ...lways use a ceramic cup or a cup suitable for use with hot water Do not hold cup or place hands in dispensing area whilst dispensing water Do not dispense water in a stop start style of vending Hold t...

Страница 9: ...the machine 12 Check that the UV lamp is alight by observing a blue glow from the top of the UV cap Do not remove the lamp from holder whilst ignited and do not look into an ignited UV light 13 Close...

Страница 10: ...nk mechanism being frozen Ensure that the thermostat is set at the factory setting Disconnect the power mains from the back of the machine and allow the ice inside the cold tank to melt 3 Water dispen...

Страница 11: ...icy of constant and continual improvement and therefore reserves the right to change specifications without prior notice other than in the case of significant changes Description WL 2000IT FSHC WL 200...

Страница 12: ...as been tested by an independent laboratory to show its ability to inhibit the growth of bacteria mould and fungi by up to 99 9 over a 24 hour period and for the duration of the machine life FREQUENTL...

Страница 13: ...24 25 Waterlogic 2000IT Technical Manual Issue B December 2013 Main PCB Schematic Diagram Hot and Cold...

Страница 14: ...000mm 9 JG Equal Tee Connector 1 4 10 JG Reducing Elbow Connector 5 16 1 4 11 Solenoid Valve DC24V 1000mm 12 JG LLDPE Tube Blue 8mm 13 Drawn Hot Tank Assembly 1 5L 14 Silicon Tube 5 16 15 JG LLD PE Tu...

Страница 15: ...r Socket 8 Plastic Handle Silver 9 Plastic Cap for 1 4 Bulkhead Fitting 10 JG Bulkhead Connector Union 1 4 1 4 11 Compressor 12 WL2000 Down Base 13 Unit Control Rubber Feet 14 Bolt M6 30 15 WL2000 Fil...

Страница 16: ...31 Button Label WL2000 HC CA 32 WL2000 Drip Tray Grill 33 WL2000 Drip Tray Body Charcoal 34 FS Silver Side Panel with handle hole 35 Drawn Hot Tank Ass y 1 5L 36 WL2000 Upper Base 37 Power Transformer...

Страница 17: ...r 1 4 Bulkhead Fitting 10 Compressor 11 Mini Down Base 12 Bolt M6 30 13 Unit Control Rubber Feeet 14 Mini Filter Bracket 15 Valved Twist Filter Head 16 Carbon GAC Filter 17 Faucet HC CA 18 Front Panel...

Страница 18: ...ded Nut 28 UV Lamp 4W 29 O ring 30 Quartz Sleeve for 4W Lamp 31 Power Transformer UV 32 WL2000 Mini Upper Base 33 Ballast metal cover 34 UV Cold Tank Assembly 2L 35 JG Reducing Elbow Connector 5 16 1...

Страница 19: ...Beacon Court Sandyford Dublin 18 Ireland www waterlogic com Waterlogic USA 4141 N 156th Street Omaha NE 68116 Speak to a Water Expert Rest of the world exportsales waterlogic com 353 1 293 1960 USA Ca...