4
5
Waterlogic 2000IT Technical Manual - Issue B, December 2013
5
Machine Overview
WL 2000IT
COLD TANK
The cold tank is manufactured from 304 Stainless Steel which is non-corrosive,
inert and reflects Ultra Violet Light (UV). The cold water temperature is preset at
approximately 5°C by factory, this being ideal temperature for a cold drink.
The capacity of the cold tank is 2 liters for mini model and 4 liters for freestanding
model. When the water is stored in the Cold Tank it is chilled and exposed to UV
at the same time, this protects the water from Bacteria growth. The cold tank
temperature is controlled by a thermostat that is set at the factory. The thermostat
set point is marked at the back of the machine by a small dot. If the UV light fails,
then no cold water will be dispensed.
HOT TANK
The hot water tank has a 1.5 litre capacity for free standing and mini models. It is
manufactured from 304 stainless steel and is heated by an 800 watt heating element.
The temperature of the Hot Tank is controlled by a thermostat and it is pre-set at the
factory at approximately 87°C. A BI-metal overload thermostat is fitted to stop the
tank overheating and can be reset manually. Setting the hot water temperature at
87°C also helps stop scale forming in the Hot Tank. A special polyphosphate filter
can be fitted at the customer’s request. That will help inhibit lime scale formation.
A Minimum flow rate of 1 litre per minute is needed for the hot tank to operate
correctly.
FILTERS
The filtration system on the WL 2000IT is designed to reduce dirt and sediment
particles from the water. Furthermore, the Activated Carbon process will remove a
whole range of contaminants e.g. chlorine and pesticides. There are many kinds of
different filter combinations available from Waterlogic to suit local water conditions.
The WL 2000IT is available in the following
options:
a) Cold Only
b) Cold & Ambient
c) Hot & Cold
When reading this manual, note the
differences between the options and focus
on the particular sections that concern the
unit you have installed.
Waterlogic 2000IT Technical Manual - Issue B, December 2013