WL1000GF MAX
Manual
Page 39 Revision 10-7-2017
1.
Attach the water supply line to the 1/4” feed water hose adaptor fitting on the back of the unit.
Waterlogic
requires the use of a water pressure regulator. Water feed pressure must be
between 2.7-4Bar. Turn on the water supply and check for leaks.
2.
Verify that the Red Heater and Compressor Power Switch is the
O=OFF
position.
NOTE:
Switches have internal LED that illuminates when placed in I=ON position.
CAUTION!
NEVER TURN ON HEATER BEFORE FILLING HOT TANK.
Red Heater and Compressor Power Switch must be in the O=OFF position while the Hot Tank is
empty. Damage could occur within one minute and the overheat (high limit) will require manual
reset if heater is turned on with an empty Hot Tank.
3.
Connect the power cord to the back of the
Waterlogic WL1000GF MAX Water Treatment System
and to a 220-240 Volt supply.
4.
Turn on water supply and allow reservoir to fill.
5.
Fill the Cold Tank. Hold a container under the dispensing faucet, press and hold the cold
dispensing button until a continuous flow of water is obtained. Once a continuous flow is
obtained, release the dispensing button. Cold Tank is now full.