WL1000GF MAX
Manual
Page 36 Revision 10-7-2017
In order for our filters to perform as represented and to provide the best quality water possible, it
is essential that filters be replaced periodically. The frequency of filter changes depends upon your
water quality and your water usage. For example, if there is a lot of sediment and/or particles in
your water, then you will have to change your filters more frequently than a location with little to
no sediment. Be sure to replace your filters whenever you notice a decline in the performance,
whether it is a drop in flow rate and/or pressure or an unusual taste in the water.
12.
Flush thoroughly filters with fresh water to drain.
13.
Once flushed, install the filters. Following the flow direction on the filters.
NOTE:
Filters should not be flushed prior to 24 hours before installation to limit Microbial
Growth and must be flushed upon installation.
If you intend to use the Waterlogic Reverse Osmosis System, you must remove the filter plate
supplied behind the lower front panel (four screws total). The RO System then mounts on the rails
just above the compressor. Route the RO drain line through the port that is protected by the
rubber grommet on the back of the machine.
Red Compressor/Heater Switch must be in the O=OFF position while the Hot
Tank is empty. Damage could occur within one minute and the overheat (high
limit) will require manual reset if heater is turned on with an empty Hot Tank.
15.
Replace the Reservoir Cover and Top Cover.
16.
Turn on the Red Compressor / Heater Switch. This will start the chilling and heating processes.
Red Compressor/Heater Switch must be in the I=ON position.
17.
Verify the compressor starts by feeling the head of the compressor for vibration. The
temperature in the cold tank should reach its target temperature within 45 minutes. When the
unit has reached target cold temperature, the compressor will cycle off. The Hot Tank will take
considerably less time to reach its target temperature of 85
°
C (185
°
F).
18.
After the cold and hot water temperatures, have been reached, turn the Red Heater/Compressor
Switch off.
Red Heater and Compressor Power Switch must be in the O=OFF position
while the Hot Tank is empty. Damage could occur within one minute and the
overheat (high limit) will require manual reset if heater is turned on with an
empty Hot Tank.