P2 Classe
Manual
Page 13 – Revision: 3-2-2021
SERVICE REQUIREMENTS
WARNING!
Read and understand the contents of this manual before attempting to
service the P2 Classe. Failure to follow the instructions in this manual could result in
death, serious personal injury, or severe property damage. Only trained and qualified
technicians should attempt to install, maintain, or service Waterlogic Equipment.
1.
Visually inspect all electrical and water connections for signs of wear or damage.
DANGER!
HIGH VOLTAGE ELECTRICAL HAZARD.
Unplug before inspection and service.
2.
Waterlogic
recommends changing the UV Lamp every 12 months.
NOTE:
When replacing the UV Lamp Assembly, the UV Lamp
wiring harness must also be replaced.
WARNING!
ULTRAVIOLET RADIATION.
Protect your skin and eyes against ultraviolet
rays. Never look directly at an operating UV light. Disconnect before removing UV Lamp.
CAUTION!
UV LAMPS ARE HAZARDOUS.
Lamps are considered Hazardous Waste and
must be disposed of accordingly. Refer to Product MSDS sheet for details.
CAUTION!
UV SYSTEM IS FRAGILE.
Never handle the UV lamp or Quartz Sleeve with
bare hands. UV Lamp and quartz sleeve must be free of oils and contaminants to ensure
proper operation. Use a soft non-abrasive cloth to clean.
3.
Ensure there is adequate (minimum of 2”) clearance around the
P2 Classe
and clean the
condenser fins and compressor fan to provide efficient cooling system operation.
4.
Sanitize the cold tank per instructions in the pre-installation procedures.
WARNING!
SANITIZER MAY CONTAIN HAZARDOUS CHEMICALS.
Use of proper personal
protective equipment such as rubber gloves and eye protection is required.
5.
Clean and sanitize external surfaces of the
P2 Classe
. Use soap and water or chemicals that
are compatible with ABS plastic and will not damage or degrade the product surfaces.
UV Lamp Assembly
Part #:
15-Watt Bulb 12-8310 (CT-2085)
UV Lamp Connectors