Section 6: Trouble Shooting Guide

Problem

Possible Cause

Solution

Low or Declining 

Permeate Production

Water supply valve closed

Open valve

Crimped poly product line

Repair or replace tube

Raw water TDS too high

Consult dealer – may need pre-

treatment

Pre-treatment cartridges plugged

Replace cartridges

Membranes fouled

Clean or replace membrane

Fast flush system

Membrane installed upside down

Install element correctly

Low operating pressure

See “Low System Pressure”

Brine seal rolled out of groove

Re-install membrane using lubricant. 

Check brine seal for damage.

Feed water content has changed

Review pre-treatment

Leaking Joints

Fittings not seated

Disconnect fitting and re-seat tube

Filter housing leaking

Tighten with housing wrench.

Inspect o-rings for cuts or crimps.

Low System 

Pressure

Clogged pre-filter or fouled pre-

treatment

Replace pre-filter cartridges.

Low feed water pressure

Check feed water source for 

restrictions

Inlet solenoid closed

Check solenoid circuit. Replace if 

necessary

Drive pump malfunctioning

Call dealer

Malfunctioning pressure gauge

Replace gauge

DLFC missing or damaged

Check DLFC and replace if 

damaged

High System 

Pressure

Plugged or restricted recirculation 

valves

Clean or replace valves

Crimped product/waste line

Repair or replace tube

Malfunctioning pressure gauge

Replace gauge

Fouled membrane

Replace membrane

Permeate TDS Rising

Scaled, perforated or fouled 

membrane(s)

Clean or replace membranes

Fast flush membrane

Pre-treatment system failure

Check feed water quality

O-rings on product adapters cut or 

damaged

Check and replace damaged o-rings

Содержание VECTAPURE RSX II

Страница 1: ...ERENCE PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PRODUCT MALFUNCTIO...

Страница 2: ...d to pass through and collect in the tube while all other mineral and contaminant molecules are rejected and washed from the surface of the membrane to the drain Q What processes does the Vectapure RS...

Страница 3: ...r produced 1 Pressure The greater the RO system pressure the greater the water quantity that will be produced by the membrane Your Vectapure RSX II unit has been equipped with ultra low energy membran...

Страница 4: ...king water or water analyses indicate a rising TDS it probably means that your membrane s are deteriorating and is losing effectiveness You may purchase a pocket or full featured TDS meter from your d...

Страница 5: ...tyrene or polyacrylic regenerated with salt Chlorine Feed water should be free of chlorine 1 ppm as TFC membranes are easily damaged by chronic chlorine exposure This is an important consideration whe...

Страница 6: ...permeable membrane The concentrate stream on the other hand contains constituents that have been rejected by the membrane An inherent advantage of crossflow filtration is its ability to continuously o...

Страница 7: ...sed salt passage Carbon Filter CF Series Excelclear Carbon pH 5 5 9 5 Internal corrosion Lime scaling in equipment Plumbing damage Replace water source Adjust pH Call your dealer Organic or Microbiolo...

Страница 8: ...IDGE IN THE PRE TREATMENT FILTER HOUSINGS SUPPLIED FOR THE PRIMARY REDUCTION OF CHLORINE IT WILL REQUIRE REPLACEMENT TOO OFTEN LIMIT FLOW RATES AND LIKELY LEAD TO CHLORINE BREAKTHROUGH TO THE MEMBRANE...

Страница 9: ...h If the inlet bulkhead fitting to the non pressurized tank is below the maximum water level in the tank make sure that a check valve is installed in the product water line between the RO unit s outle...

Страница 10: ...Filter Cartridge and Membrane s 1 Remove the filter housing bowl by turning counter clockwise with the housing wrench supplied Remove all protective wrapping from the 5 micron filter cartridge Insert...

Страница 11: ...sure that they are in good condition and are secure in their seating grooves While the housing is disassembled clean all components thoroughly to remove any debris or scaling When re assembling make s...

Страница 12: ...ntial septic field for receiving the RO waste water from Vectapure RSX II systems unless the field has a rated capacity in excess of the waste flow capacity If used to 24 hour capacity these systems w...

Страница 13: ...ded for feed water of less than a TDS of 1000ppm By changing the DLFC the TDS range can be increased up to 2000ppm See spare parts for range and part numbers when ordering an alternate DLFC Make sure...

Страница 14: ...PERIOD A Note on Recovery Rates Your Vectapure RSX II is designed to operate at a recovery rate percentage of product water to total water used at maximum of 60 for feed water of 1000 TDS and 35 40 fo...

Страница 15: ...system pressure feed water TDS permeate TDS permeate flow rate and waste flow rate This will allow you to see any developing performance trends or alert you to system changes that will require you to...

Страница 16: ...parts or repair service during the warranty period Read the document completely for warranty claim instructions Your Vectapure RSX II system comes with a limited one year warranty covering materials...

Страница 17: ...housing leaking Tighten with housing wrench Inspect o rings for cuts or crimps Low System Pressure Clogged pre filter or fouled pre treatment Replace pre filter cartridges Low feed water pressure Chec...

Страница 18: ...oduct Adapter O ring N70209 Membrane Housing End Cap O ring N70328 Pre Filter Housing O ring RKE0013HLB Black Max 2521 Membrane TFC LP BME2521SL Drive Pump 100 GPH APR3BZ Drive Pump 140 GPH APR4BZ Dri...

Страница 19: ...II 350 2 0 USGPM minimum includes 20 safety factor RSX II 700 3 0USGPM minimum on 1000 TDS feed water Feed water must be available at a minimum of 40 psi and a maximum of 80 psi at the specified flow...

Страница 20: ...20 Section 10 Vectapure RSX II Performance Log Date Line Pressure System Pressure Permeate TDS Feed Water TDS Pre Filter Change Fast Flush Permeate Flow Meter Waste Flow Meter...

Страница 21: ...er Quality Owner Contact Installation Date Phone Serial Dealer Model CATIONS ANIONS Barium Bromide Calcium Chloride Iron Fluoride Potassium Bicarbonate Magnesium Sulphate Manganese Nitrate Sodium Phos...

Страница 22: ...22 REGISTER YOUR PRODUCT ONLINE AT WATERITE COM OR FILL OUT THE INCLUDED PRE PAID SELF ADDRESSED POSTCARD...

Страница 23: ...23 REGISTER YOUR PRODUCT ONLINE AT WATERITE COM OR FILL OUT THE INCLUDED PRE PAID SELF ADDRESSED POSTCARD...

Страница 24: ...24 Waterite Inc Winnipeg Manitoba Canada www waterite com...

Отзывы: