background image

3

Q: What other contaminants does reverse osmosis remove?

The combined filtering and RO processes in your system will remove more than 98% of many 

organic compounds, including THMs (chloroforms), DBCP, lindane, TCE (trichloroethylene), PCE 

(tetrachloroethylene), carbon tetrachloride and chlorine. Very conservatively, a TFC membrane will 

remove the following percentages of contaminants: Barium 97%, Potassium 92%, Bicarbonate 94%, 

Radium 97%, Cadmium 97%, Selenium 97%, Calcium 97%, Silicates 96%, Chromium 92%, Silver 

85%, Copper 97%, Sodium 92%, Detergents 97%, Strontium 97%, Fluoride 90%, Sulphates 97%, Lead 

97%, PCBs 97%, Magnesium 97%, Insecticides 97%, Nickel 97%, Herbicides 97%, Nitrates 80%, Total 

Dissolved Solids 97%. 

Q: Where is the system installed?

Each application will require access to the feed water source, electrical power and a drain for the 

wastewater to be routed to.  The system should be protected from the elements and at all times 

protected from freezing.  If the system is used to provide water to a critical piece of equipment, you may 

consider protection from power surges and lightning strikes.

Q: Can the Vectapure™ RSX II system be connected multiple appliances?

Yes.  Many installations will involve providing water to multiple appliances or pieces of equipment 

simultaneously.

  

Make sure that the peak usage of water for the combined equipment does not exceed 

the output of your RO system or its product water storage.  See your dealer for

 

advice and parts

.

Q: What factors affect the quantity and the quality of the water produced?

1.  Pressure: The greater the RO system pressure, the greater the water quantity that will be produced 

by the membrane.  Your Vectapure™ RSX II unit has been equipped with ultra- low energy 

membrane(s) that are designed to operate at a minimum system pressure of 100 psi. (7.0 kg/

cm²) and a maximum of 150 psi (9.0 kg/cm²)  Do not attempt to operate your system at pressures 

exceeding 150 psi, as damage to the membrane or premature fouling may result.

2.  Temperature: Production increases with temperature, standard ratings established at 25°C.  Never 

operate the system from the hot water line or with water exceeding 35°C, as this will damage the 

membrane and internal components.

3.  Membrane type: VectaPure ™ RSX II systems use premium quality TFC (Thin Film Composite) 

membranes, specially chosen for general commercial applications.  Please contact your dealer or 

Waterite for information on special application or nanofiltration membranes.

4.  TDS: The higher the Total Dissolved Solids in the raw water, the lower the rate of output of product 

water. 

Q: How much water does the Vectapure™ RSX II system produce?

Vectapure ™ RSX II systems use a

 

membrane nominally rated for 350 GPD.  Actual output will be de-

pendent upon the factors explained above.  In optimal applications (low feed water TDS, feed water = 

25°C, you may expect 260-350 USG from each membrane to be available over 24 hours. 

!

THIS REVERSE OSMOSIS WATER SYSTEM IS DESIGNED ONLY TO IMPROVE AESTHETIC 

PROPERTIES AND IS NOT DESIGNED TO ACT AS A PRIMARY BARRIER TO WATERBORNE 

MICROBIOLOGICAL OR TOXIC CHEMICAL CONTAMINATION.  

WHERE THESE CONDITIONS 

MAY EXIST CONSULT A WATER PROFESSIONAL TO ENSURE SUFFICIENT RAW WATER PRE-

TREATMENT AND DISINFECTION.

Содержание VECTAPURE RSX II

Страница 1: ...ERENCE PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PRODUCT MALFUNCTIO...

Страница 2: ...d to pass through and collect in the tube while all other mineral and contaminant molecules are rejected and washed from the surface of the membrane to the drain Q What processes does the Vectapure RS...

Страница 3: ...r produced 1 Pressure The greater the RO system pressure the greater the water quantity that will be produced by the membrane Your Vectapure RSX II unit has been equipped with ultra low energy membran...

Страница 4: ...king water or water analyses indicate a rising TDS it probably means that your membrane s are deteriorating and is losing effectiveness You may purchase a pocket or full featured TDS meter from your d...

Страница 5: ...tyrene or polyacrylic regenerated with salt Chlorine Feed water should be free of chlorine 1 ppm as TFC membranes are easily damaged by chronic chlorine exposure This is an important consideration whe...

Страница 6: ...permeable membrane The concentrate stream on the other hand contains constituents that have been rejected by the membrane An inherent advantage of crossflow filtration is its ability to continuously o...

Страница 7: ...sed salt passage Carbon Filter CF Series Excelclear Carbon pH 5 5 9 5 Internal corrosion Lime scaling in equipment Plumbing damage Replace water source Adjust pH Call your dealer Organic or Microbiolo...

Страница 8: ...IDGE IN THE PRE TREATMENT FILTER HOUSINGS SUPPLIED FOR THE PRIMARY REDUCTION OF CHLORINE IT WILL REQUIRE REPLACEMENT TOO OFTEN LIMIT FLOW RATES AND LIKELY LEAD TO CHLORINE BREAKTHROUGH TO THE MEMBRANE...

Страница 9: ...h If the inlet bulkhead fitting to the non pressurized tank is below the maximum water level in the tank make sure that a check valve is installed in the product water line between the RO unit s outle...

Страница 10: ...Filter Cartridge and Membrane s 1 Remove the filter housing bowl by turning counter clockwise with the housing wrench supplied Remove all protective wrapping from the 5 micron filter cartridge Insert...

Страница 11: ...sure that they are in good condition and are secure in their seating grooves While the housing is disassembled clean all components thoroughly to remove any debris or scaling When re assembling make s...

Страница 12: ...ntial septic field for receiving the RO waste water from Vectapure RSX II systems unless the field has a rated capacity in excess of the waste flow capacity If used to 24 hour capacity these systems w...

Страница 13: ...ded for feed water of less than a TDS of 1000ppm By changing the DLFC the TDS range can be increased up to 2000ppm See spare parts for range and part numbers when ordering an alternate DLFC Make sure...

Страница 14: ...PERIOD A Note on Recovery Rates Your Vectapure RSX II is designed to operate at a recovery rate percentage of product water to total water used at maximum of 60 for feed water of 1000 TDS and 35 40 fo...

Страница 15: ...system pressure feed water TDS permeate TDS permeate flow rate and waste flow rate This will allow you to see any developing performance trends or alert you to system changes that will require you to...

Страница 16: ...parts or repair service during the warranty period Read the document completely for warranty claim instructions Your Vectapure RSX II system comes with a limited one year warranty covering materials...

Страница 17: ...housing leaking Tighten with housing wrench Inspect o rings for cuts or crimps Low System Pressure Clogged pre filter or fouled pre treatment Replace pre filter cartridges Low feed water pressure Chec...

Страница 18: ...oduct Adapter O ring N70209 Membrane Housing End Cap O ring N70328 Pre Filter Housing O ring RKE0013HLB Black Max 2521 Membrane TFC LP BME2521SL Drive Pump 100 GPH APR3BZ Drive Pump 140 GPH APR4BZ Dri...

Страница 19: ...II 350 2 0 USGPM minimum includes 20 safety factor RSX II 700 3 0USGPM minimum on 1000 TDS feed water Feed water must be available at a minimum of 40 psi and a maximum of 80 psi at the specified flow...

Страница 20: ...20 Section 10 Vectapure RSX II Performance Log Date Line Pressure System Pressure Permeate TDS Feed Water TDS Pre Filter Change Fast Flush Permeate Flow Meter Waste Flow Meter...

Страница 21: ...er Quality Owner Contact Installation Date Phone Serial Dealer Model CATIONS ANIONS Barium Bromide Calcium Chloride Iron Fluoride Potassium Bicarbonate Magnesium Sulphate Manganese Nitrate Sodium Phos...

Страница 22: ...22 REGISTER YOUR PRODUCT ONLINE AT WATERITE COM OR FILL OUT THE INCLUDED PRE PAID SELF ADDRESSED POSTCARD...

Страница 23: ...23 REGISTER YOUR PRODUCT ONLINE AT WATERITE COM OR FILL OUT THE INCLUDED PRE PAID SELF ADDRESSED POSTCARD...

Страница 24: ...24 Waterite Inc Winnipeg Manitoba Canada www waterite com...

Отзывы: