3
Q: What other contaminants does reverse osmosis remove?
The combined filtering and RO processes in your system will remove more than 98% of many
organic compounds, including THMs (chloroforms), DBCP, lindane, TCE (trichloroethylene), PCE
(tetrachloroethylene), carbon tetrachloride and chlorine. Very conservatively, a TFC membrane will
remove the following percentages of contaminants: Barium 97%, Potassium 92%, Bicarbonate 94%,
Radium 97%, Cadmium 97%, Selenium 97%, Calcium 97%, Silicates 96%, Chromium 92%, Silver
85%, Copper 97%, Sodium 92%, Detergents 97%, Strontium 97%, Fluoride 90%, Sulphates 97%, Lead
97%, PCBs 97%, Magnesium 97%, Insecticides 97%, Nickel 97%, Herbicides 97%, Nitrates 80%, Total
Dissolved Solids 97%.
Q: Where is the system installed?
Each application will require access to the feed water source, electrical power and a drain for the
wastewater to be routed to. The system should be protected from the elements and at all times
protected from freezing. If the system is used to provide water to a critical piece of equipment, you may
consider protection from power surges and lightning strikes.
Q: Can the Vectapure™ RSX II system be connected multiple appliances?
Yes. Many installations will involve providing water to multiple appliances or pieces of equipment
simultaneously.
Make sure that the peak usage of water for the combined equipment does not exceed
the output of your RO system or its product water storage. See your dealer for
advice and parts
.
Q: What factors affect the quantity and the quality of the water produced?
1. Pressure: The greater the RO system pressure, the greater the water quantity that will be produced
by the membrane. Your Vectapure™ RSX II unit has been equipped with ultra- low energy
membrane(s) that are designed to operate at a minimum system pressure of 100 psi. (7.0 kg/
cm²) and a maximum of 150 psi (9.0 kg/cm²) Do not attempt to operate your system at pressures
exceeding 150 psi, as damage to the membrane or premature fouling may result.
2. Temperature: Production increases with temperature, standard ratings established at 25°C. Never
operate the system from the hot water line or with water exceeding 35°C, as this will damage the
membrane and internal components.
3. Membrane type: VectaPure ™ RSX II systems use premium quality TFC (Thin Film Composite)
membranes, specially chosen for general commercial applications. Please contact your dealer or
Waterite for information on special application or nanofiltration membranes.
4. TDS: The higher the Total Dissolved Solids in the raw water, the lower the rate of output of product
water.
Q: How much water does the Vectapure™ RSX II system produce?
Vectapure ™ RSX II systems use a
membrane nominally rated for 350 GPD. Actual output will be de-
pendent upon the factors explained above. In optimal applications (low feed water TDS, feed water =
25°C, you may expect 260-350 USG from each membrane to be available over 24 hours.
!
THIS REVERSE OSMOSIS WATER SYSTEM IS DESIGNED ONLY TO IMPROVE AESTHETIC
PROPERTIES AND IS NOT DESIGNED TO ACT AS A PRIMARY BARRIER TO WATERBORNE
MICROBIOLOGICAL OR TOXIC CHEMICAL CONTAMINATION.
WHERE THESE CONDITIONS
MAY EXIST CONSULT A WATER PROFESSIONAL TO ENSURE SUFFICIENT RAW WATER PRE-
TREATMENT AND DISINFECTION.