2.  Remove the wrapping from the membrane element(s).  Lightly lubricate the membrane brine seal 

and all o-rings located in the membrane housing caps with a good quality, silicone o-ring lubricant 

(do not use petroleum-based lubricants).  Disconnect the connections on the membrane housing’s 

top end cap.  Remove the end cap from the membrane housing by loosening the band clamp 

nuts and bolts.  The membrane housing is mounted vertically on the system’s stand.  See Figure 

1.  Insert the membrane element into the housing, so that the brine seal of the membrane will 

seat at the inlet side of the membrane housing (this is indicated by the direction of flow label on 

the housing).  See Figure 3.   Gently push and slowly twist until the membrane product adapter 

seats snugly inside the housing cap still in place at the bottom of the housing.  Re-install the 

disassembled housing cap - be sure that o-rings do not roll out of their grooves, get pinched or cut.  

Re-install the band clamp snugly and reconnect the connections to the cap.

3.  To remove the membrane from the housing, remove the top housing end cap and gently pull the 

membrane out of the housing body.  You may need to lightly grip the membrane cage with needle-

nose pliers to free it from the housing, after extended use.  With each disassembly, always check 

the end cap o-rings and the membrane brine seal to make sure that they are in good condition 

and are secure in their seating grooves.  While the housing is disassembled, clean all components 

thoroughly to remove any debris or scaling.  When re-assembling, make sure that the membrane 

element is installed with the brine seal facing in the same direction as it was previously.  See 

direction of flow label on each membrane housing. In order to monitor TDS reduction a TDS monitor 

is available. Order Part # RSXTDS

Step 6. Install the Feed Water Supply Connection

1.  Inspect the cold water supply line and the condition of the pipe.  Ensure that the supply pipe is in 

good overall condition and is capable of delivering the system’s necessary feed water flow rate.  

See Section 8 for specified feed water flow rate requirements.

2.  Turn the water supply line to your plumbing OFF.

3.  Plumb a connection from the 

COLD

 water supply line, ensuring that the feed line is at least 1/2” in 

diameter.  Install a shut off valve on the connection, so that the RO system can by isolated from the 

main water supply.  Note that the inlet connection to your RO system is 3/8” push in fitting. Push 

the 3/8” tube into the fitting following directions in the previous section. You may now turn the water 

supply to the plumbing system ON.  Check for leaks around the RO connection. Purge air from the 

filter bowl by pressing the red button on top of the filter housing until no more air comes out. Correct 

any leaks, if necessary.

Figure 3

Brine Seal

Membrane Cage

Product Adapter

Groove Clamp

Direction of Flow Label

Membrane Housing Body

End Cap

O-Rings

Содержание VECTAPURE RSX II

Страница 1: ...ERENCE PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PRODUCT MALFUNCTIO...

Страница 2: ...d to pass through and collect in the tube while all other mineral and contaminant molecules are rejected and washed from the surface of the membrane to the drain Q What processes does the Vectapure RS...

Страница 3: ...r produced 1 Pressure The greater the RO system pressure the greater the water quantity that will be produced by the membrane Your Vectapure RSX II unit has been equipped with ultra low energy membran...

Страница 4: ...king water or water analyses indicate a rising TDS it probably means that your membrane s are deteriorating and is losing effectiveness You may purchase a pocket or full featured TDS meter from your d...

Страница 5: ...tyrene or polyacrylic regenerated with salt Chlorine Feed water should be free of chlorine 1 ppm as TFC membranes are easily damaged by chronic chlorine exposure This is an important consideration whe...

Страница 6: ...permeable membrane The concentrate stream on the other hand contains constituents that have been rejected by the membrane An inherent advantage of crossflow filtration is its ability to continuously o...

Страница 7: ...sed salt passage Carbon Filter CF Series Excelclear Carbon pH 5 5 9 5 Internal corrosion Lime scaling in equipment Plumbing damage Replace water source Adjust pH Call your dealer Organic or Microbiolo...

Страница 8: ...IDGE IN THE PRE TREATMENT FILTER HOUSINGS SUPPLIED FOR THE PRIMARY REDUCTION OF CHLORINE IT WILL REQUIRE REPLACEMENT TOO OFTEN LIMIT FLOW RATES AND LIKELY LEAD TO CHLORINE BREAKTHROUGH TO THE MEMBRANE...

Страница 9: ...h If the inlet bulkhead fitting to the non pressurized tank is below the maximum water level in the tank make sure that a check valve is installed in the product water line between the RO unit s outle...

Страница 10: ...Filter Cartridge and Membrane s 1 Remove the filter housing bowl by turning counter clockwise with the housing wrench supplied Remove all protective wrapping from the 5 micron filter cartridge Insert...

Страница 11: ...sure that they are in good condition and are secure in their seating grooves While the housing is disassembled clean all components thoroughly to remove any debris or scaling When re assembling make s...

Страница 12: ...ntial septic field for receiving the RO waste water from Vectapure RSX II systems unless the field has a rated capacity in excess of the waste flow capacity If used to 24 hour capacity these systems w...

Страница 13: ...ded for feed water of less than a TDS of 1000ppm By changing the DLFC the TDS range can be increased up to 2000ppm See spare parts for range and part numbers when ordering an alternate DLFC Make sure...

Страница 14: ...PERIOD A Note on Recovery Rates Your Vectapure RSX II is designed to operate at a recovery rate percentage of product water to total water used at maximum of 60 for feed water of 1000 TDS and 35 40 fo...

Страница 15: ...system pressure feed water TDS permeate TDS permeate flow rate and waste flow rate This will allow you to see any developing performance trends or alert you to system changes that will require you to...

Страница 16: ...parts or repair service during the warranty period Read the document completely for warranty claim instructions Your Vectapure RSX II system comes with a limited one year warranty covering materials...

Страница 17: ...housing leaking Tighten with housing wrench Inspect o rings for cuts or crimps Low System Pressure Clogged pre filter or fouled pre treatment Replace pre filter cartridges Low feed water pressure Chec...

Страница 18: ...oduct Adapter O ring N70209 Membrane Housing End Cap O ring N70328 Pre Filter Housing O ring RKE0013HLB Black Max 2521 Membrane TFC LP BME2521SL Drive Pump 100 GPH APR3BZ Drive Pump 140 GPH APR4BZ Dri...

Страница 19: ...II 350 2 0 USGPM minimum includes 20 safety factor RSX II 700 3 0USGPM minimum on 1000 TDS feed water Feed water must be available at a minimum of 40 psi and a maximum of 80 psi at the specified flow...

Страница 20: ...20 Section 10 Vectapure RSX II Performance Log Date Line Pressure System Pressure Permeate TDS Feed Water TDS Pre Filter Change Fast Flush Permeate Flow Meter Waste Flow Meter...

Страница 21: ...er Quality Owner Contact Installation Date Phone Serial Dealer Model CATIONS ANIONS Barium Bromide Calcium Chloride Iron Fluoride Potassium Bicarbonate Magnesium Sulphate Manganese Nitrate Sodium Phos...

Страница 22: ...22 REGISTER YOUR PRODUCT ONLINE AT WATERITE COM OR FILL OUT THE INCLUDED PRE PAID SELF ADDRESSED POSTCARD...

Страница 23: ...23 REGISTER YOUR PRODUCT ONLINE AT WATERITE COM OR FILL OUT THE INCLUDED PRE PAID SELF ADDRESSED POSTCARD...

Страница 24: ...24 Waterite Inc Winnipeg Manitoba Canada www waterite com...

Отзывы: