3 If you use the sensor port on the wireless valve control:
Test the safety function for the sensor cable by pulling it out.
• A quick approx. 0.5 sec repeating audio signal is heard.
• The LED indicatior in the RESET button vil alternate red and green.
• Water in the tap will stop flowing. Control that the water starts flowing
again when the sensor cable is put back in.
4 With a moist cloth wet one of the sensor points on the sensor tape.
5
The valve control will now indicate a leak with repeating audio signals approx every secont. The
LED-indicator in the RESET button will emit a red light, and the valve will close the water.
6 Check that water stops flowing from the open tap.
7 Push RESET once to stop the audible alarm, the water should remain closed.
8 Wait one minute while thoroughly drying the moist sensor point.
9 Now, stop the alarm by pushing the central unit’s RESET button twice.
The audio signal from the central unit will stop, and LED-OFF will change to LED-ON.
10 Control that the water still flows from the open tap.
11 Moisten the sensor point on the first wireless sensor. The drop in the Waterguard logo will light up
red when moist i detected, and an alarm signal is being sent.
12 The water in the tap shall close, and the central unit will emit the number of beeps that
corresponds with the triggered sensor. Now, wipe the sensor’s moist parts thoroughly!
13 The wireless central unit can now be reset by pusing the RESET button twice.
14 Check that the water starts flowing from the tap.
15 Repeat the procedure with the other wireless sensors, and be sure to dry all sensor points
thoroughly after the test.