IN CASE OF ALARM

1    The system has two types of alarms when detecting a 

leak:

2   A wireless sensor detection will only be alarmed in the 

wireles control panel.

3   A leakage detected by the valve control’s sensor cable  

will be alarmed both on the valve control and on the 
control panel.

4   A leak alarm from a wireless sensor can only be reset/

cancelled on the control panel. An alarm from the valve 
control’s sensor cable must be reset/cancelled first on 
the valve control, then on the control panel. 

5   If there is water on the valve control’s sensor cable, the control will emit repeating 1-second alarm 

signals, and the Reset-button will display a red light. The solenoid valve now has closed the incoming 
water. Also the central unit will sound an alarm, and LED OFF will light up.

6   If there is water on a wireless sensor, only the control panel will sound an alarm and light up LED OFF. 

Also, the solenoid valve will close the water supply.

7   When an alarm is triggered, this is either due to a water leak or other factors such as cleaning with water 

etc.

8   Localize the water leak or spill, and dry up thoroughly.
9   The alarm signal from the units can be stopped by pushing the RESET-button once. The solenoid valve 

will still be closed.

10 In case of a real water leak, close the main stopcock and contact a plumber.
11 When the damage or spill is taken care of, be sure to carefully wipe off the wet parts of the sensor.
12 Push the RESET-button and the light will change from red to blue. The solenoid valve will open.

TESTING THE SYSTEM (at least twice a year)

1  Open a tap and let the water run.
2  With a wet cloth, moist one of the sensor-points. The valve should now close the water flow.
3  Make sure the water in the open tap has stopped.
4   With a dry cloth, dry the moist sensor point thoroughly. Push the RESET-button on the central unit to 

cancel the alarm. The alarm signal should now stop, and the LED should change from red to blue. The 
valve will open again.

5    Test all wireless sensors and sensor cables. NB: If the sensor port on the valve control is activated, the 

valve control must be reset before the central unit ca be reset!

RESET BUTTON

Содержание Smart Stop 5648191

Страница 1: ...INSTALLATION INSTRUCTIONS USER MANUAL SMART STOP Version May 25 2020...

Страница 2: ...TALLATION INSTRUCTIONS USER MANUAL 2 1 valve 1 2 ART NO 5648191 1 valve 3 4 ART NO 5648193 1 valve 1 2 NC ART NO 5648195 1 valve 3 4 NC ART NO 5648197 This information is valid for these Smart Stop ty...

Страница 3: ...to 2 dimensions A3 WTG 36C WIRELESS VALVE CONTROL NC Activates the solenoid valve when a leak is detected by the system 4 WIRELESS SENSOR ART NO 5648275 Battery powered wireless sensor 5 SPLIT CABLE...

Страница 4: ...s a 230V AC 10A socket for dishwashers etc In case of a leak the valve control will interrupt the power to this socket NB THIS SOCKET IS NOT DESIGNED FOR CONNECTING WATER HEATERS Ref NEK 400 Norsk Ele...

Страница 5: ...e will open and close very fast without influencing the waterflow The unit comes pre preogrammed with one exercising cycle every 24 hour This can be changed to the following frequency 1 time every 24...

Страница 6: ...board ill 2 page 11 on the first wireless sensor for abt 1 second The central unit will emit audio signals and a small light diode will flash for abt 1 5 seconds This indicates a successful registrat...

Страница 7: ...stalled after that 2 Filter MUST be installed where water can be contaminated by dirt or particles 3 See to that sealing material used does not enter the valve by assembly 4 The solenoid valve can be...

Страница 8: ...n be cut to desired lengths Cutting it in two it can be connected to 2 units Test the functionality by moisting some of the sensor points before you start using the system START AND TEST Test the syst...

Страница 9: ...the audible alarm the water should remain closed 8 Wait one minute while thoroughly drying the moist sensor point 9 Now stop the alarm by pushing the central unit s RESET button twice The audio signal...

Страница 10: ...CE ENTRANCE KITCHEN KITCHEN KITCHEN KITCHEN KITCHEN KITCHEN WASHING ROOM WASHING ROOM BATHROOM BATHROOM TECHNICAL ROOM TECHNICAL ROOM WIRELESS SENSOR WIRELESS SENSOR SENSOR TAPE SENSOR TAPE FILTER SIL...

Страница 11: ...an alarm is triggered this is either due to a water leak or other factors such as cleaning with water etc 8 Localize the water leak or spill and dry up thoroughly 9 The alarm signal from the units ca...

Страница 12: ...sh of RESET Take note of the number of signals which sensor has triggered before you reset the alarm 1 Remove the sensor from the wall bracket by pulling it approx 5mm upwards and then pulling it stra...

Страница 13: ...e control is mounted Wireless sensor 1 is mounted Wireless sensor 2 is mounted Wireless sensor 3 is mounted Wireless sensor 4 is mounted Wireless sensor 5 is mounted Wireless sensor 6 is mounted Wirel...

Отзывы: