User manual
IN CASE OF ALARM
1 The system has two types of alarms when detecting a
leak:
2 A wireless sensor detection will only be alarmed in the
wireles control panel.
3 A leakage detected by the valve control’s sensor cable
will be alarmed both on the valve control and on the
control panel.
4 A leak alarm from a wireless sensor can only be reset/
cancelled on the control panel. An alarm from the valve
control’s sensor cable must be reset/cancelled first on
the valve control, then on the control panel.
5 If there is water on the valve control’s sensor cable, the control will emit repeating 1-second alarm
signals, and the Reset-button will display a red light. The solenoid valve now has closed the incoming
water. Also the central unit will sound an alarm, and LED OFF will light up.
6 If there is water on a wireless sensor, only the control panel will sound an alarm and light up LED OFF.
Also, the solenoid valve will close the water supply.
7 When an alarm is triggered, this is either due to a water leak or other factors such as cleaning with water
etc.
8 Localize the water leak or spill, and dry up thoroughly.
9 The alarm signal from the units can be stopped by pushing the RESET-button once. The solenoid valve
will still be closed.
10 In case of a real water leak, close the main stopcock and contact a plumber.
11 When the damage or spill is taken care of, be sure to carefully wipe off the wet parts of the sensor.
12 Push the RESET-button and the light will change from red to blue. The solenoid valve will open.
TESTING THE SYSTEM (at least twice a year)
1 Open a tap and let the water run.
2 With a wet cloth, moist one of the sensor-points. The valve should now close the water flow.
3 Make sure the water in the open tap has stopped.
4 With a dry cloth, dry the moist sensor point thoroughly. Push the RESET-button on the central unit to
cancel the alarm. The alarm signal should now stop, and the LED should change from red to blue. The
valve will open again.
5 Test all wireless sensors and sensor cables. NB: If the sensor port on the valve control is activated, the
valve control must be reset before the central unit ca be reset!
RESET BUTTON