INSTALLATION INSTRUCTIONS / USER MANUAL
6
WIRELESS UNITS
Prior to assembly, the wireless units must be registred in the central unit!
Connect the wireless central unit to power.
Connect the wireless valve control to power, connect the solenoid valve(s)s to the valve control.
Open up the wireless sensor and insert batteries, do not put back the lid.
1 On the central unit push and hold RESET for abt. 2 seconds. The panel at first will emit one beep and
then two beeps, the unit is now ready for registration in the wireless unit.
2 On the valve control, push and hold the RESET button until two beeps are heard. In a few seconds the
units are registred, and they will emit another audio signal to confirm the registration.
3 Repeat part 1.
4 Push the small swith on top of the circuit board (ill. 2 page 11) on the first wireless sensor for abt. 1
second. The central unit will emit audio signals, and a small light diode will flash for abt. 1,5 seconds.
This indicates a successful registration/pairing.
5 If more wireless sensors or wirless valve controls are to be paired, repeat the above described process.
. If a unit is registered more than once, it will be given an new ID every time.
If a unit is registered so many times that the number of beeps are too high, you can tidy up in this by
erasing registrations. That is done this way:
On the wireless central unit press and hold RESET for abt. 5 seconds – until you hear 5 short beeps.
By re-registrating a previously registerated unit, they will get a new ID-number starting on 1.
By failing to re-register, you risk having two wireless units wih the same ID-number. While not corrupting
functionality, you will not be able to identify the triggered unit based on the number of beeps.
Registrating/pairing wireless units