![WATERGUARD Smart Stop 5648191 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/waterguard/smart-stop-5648191/smart-stop-5648191_installation-instructions-and-user-manual_3615412007.webp)
INSTALLATION INSTRUCTIONS / USER MANUAL
7
WIRELESS CENTRAL UNIT/CONTROL PANEL
1 The wireless central unit should be mounted in a concealed wallbox so that the enclosed power supply
can be placed inside the box. This willl ensure a good looking installation and stable power supply. It can
also be placed inside one of the underlaying swithces’ wallboxes, running the wires up from below the
swithches frame. Alternatively use a multibox, ex. Elko Multibox PFXP - Elnummer 1223740.
2 The enclosed plugable power supply can be used instead of the internal one, but be aware that if this is
unintentionally disconnected from the socket, the wireless units will no longer function!
SOLENOID VALVE
The solenoid valve must be installed by a professional plumber, in frost-free invironments.
1 The solenoid valve is preferably mounted on the cold water intake after the main stopcock. If a fire hose
is installed, the solenoid valve MUST be installed after that.
2 Filter MUST be installed where water can be contaminated by dirt or particles.
3 See to that sealing material used does not enter the valve by assembly.
4 The solenoid valve can be installed horisontally or vertically. When installed horisontally, the electric coil
must never face downwards. When mounted vertically the electric contact must allways be on top of the
coil.
5 The solenoid valve must be installed in the direction of waterflow, see arrow on the housing.
WIRELESS VALVE CONTROL AND SENSORTAPE
1 The valve control is installed in a 230V grounded socket close to the valve and the monitored area.
2 Connect the Jack-adapter to the valve control, and fasten it with cable fasteners to the floor.
3 The sensor tape is fastened to the Jack-adapter with the blue tape-strip on the end.
4 Remove the protective cover from the sensor tape underside, and glue the tape to the floor/underlay
where water from a leak may gather.
5 Conncect the solenoid valve contact to the valve control using the enclosed screw. Tighten carefully to
slightly sqeeze the contact to the valve coil.
Installation instructions