background image

WATERGROUP INC.

WATERGROUP COMPANIES INC.

193 Osborne Road

580 Park Street

265 Industrial Road

Fridley, MN 55432

Regina, SK S4N 5A9

Cambridge, ON N3H 5N3

1-763-571-9001

1-306-761-3200

www.watergroup.com

Warranty

Five Year Limited Warranty:

Your new drinking system is warranted to the original consumer purchaser, when located at the original installation site, to
be  free  from  defects  in  material  and  workmanship  under  normal  use  within  the  application  guidelines  specified  by  the
manufacturer and subject to regular maintenance as described in the Owner’s Manual. The entire system (excluding the
reverse osmosis membrane and the disposable filter cartridges, which are not warranted) is warranted for a period of five
years from date of purchase and we will repair or replace any part which we find to be defective in operation because of
faulty materials or workmanship.

Two Year Pro-Rated Warranty

The reverse osmosis membrane is warranted to be free from defects in material and workmanship for one year from date
of purchase, when operated within the application guidelines. If found to be defective, we will replace said membrane free
of charge. Should the membrane fail within the second year of service, you may purchase a new replacement module at a
price equal to 3% of the then current retail price, times the number of months or portion thereof of service delivered by the
original membrane. The membrane is not warranted beyond the two year period.

Condition of Warranty

Damage to any part of this reverse osmosis unit because of misuse, misapplication, neglect, alteration, accident, physical
damage, fouling and/or scaling of membrane by dirt, sediment, minerals or bacteria attack, installation or operation contrary
to  our  printed  instructions  or  damage  caused  by  hot  water,  freezing,  flood,  fire  or Act  of  God,  is  not  covered  by  this
warranty. In all such cases, regular parts and service charges will apply. This warranty is void if unit is altered or repaired
by anyone other than an authorized service representative. 

All shipping charges on units or parts submitted to our facility for repair or replacement must be borne by the registered
purchaser, as well as any costs or labor charges resulting from the removal or installation of the repaired or replaced part.

The drinking water system must be installed on a potable water supply and is not warranted to render an unsafe water
supply potable.

This warranty is in lieu of all other warranties, expressed or implied, including warranties of fitness for a particular purpose.
Because  of  fluctuating  water  quality  and  varying  usage  rate,  we  assume  no  liability  for  the  determination  of  the  proper
equipment  necessary  to  meet  your  requirements  and  we  do  not  authorize  others  to  assume  for  us  such  or  any  other
obligations on the sale of this drinking water system.

We  assume  no  warranty  liability  in  connection  with  this  reverse  osmosis  unit  other  than  as  specified  herein. This  is  the
exclusive remedy and liability for incidental and consequential damages or injury to person or property, attributable to the
manufacturer's negligence or fault, under any and all warranties are excluded to the extent exclusion is permitted by law.

Содержание E50TFC-3NSF

Страница 1: ...omy Reverse Osmosis Drinking Water System Installation Operation and Service Manual 90016 8 08 Models E50TFC 3NSF and E75TFC 3NSF are tested and certified by WQA against NSF ANSI 58 for the reduction of TDS ...

Страница 2: ...sh out the preservative solution before using the system This volume of water represents approximately two days of production The water flushed should be disposed of to the drain Feed Water Quality This reverse osmosis drinking water system is not intended to be used for the treatment of water that is microbiologically unsafe or of unknown quality If the feed water quality is unsafe or unknown hav...

Страница 3: ...embly 7 Installation of Ball Valve Assembly 8 Drilling Sink Hole 8 Installation of Non Air Gap Faucet 8 Installation of Wall Mounted Airgap 9 Installation of Filters 10 Installation of Membrane 10 Connecting Components 10 Start up Procedure 11 Maintenance Schedule 12 Sanitization Procedure for your Reverse Osmosis System 13 Maintenance Record 16 Reverse Osmosis Drinking Water System Flow Diagram a...

Страница 4: ...rectly from the tap Ice Cubes use RO water to fill ice cube trays Ice cubes made from RO water are typically clearer and better tasting than ice made from plain tap water Automatic Ice Makers a water line from the RO system can be plumbed to refrigerators with automatic icemakers Additional accessories required to complete this connection are not included Please consult the refrigerator s owner s ...

Страница 5: ...ULATOR IS RECOMMENDED FOR FEED WATER PRESSURES EXCEEDING 552 kPa 80 psig Models System Configurations Conditions for Use Item Model Storage of Storage Tank Vessel Vessel Vessel Vessel Daily Production Efficiency Recovery Number Description Tank Vessels Capacity Litres gal 1 2 3 4 Rate 2 L day G day Rating 3 Rating 4 2885 RO E50TFC 3NSF Plastic 4 6 1 6 Sediment Filter Carbon Filter TFC 1 Membrane C...

Страница 6: ...04 27 Tubing 1 4 OD poly red 115201 28 Airgap RO Remote Plastic 44403001 Drawing No Description Item No Membranes and Filters 10 Reverse Osmosis TFC Membrane 50 GPD TFC 92607 75 GPD TFC 92608 12 Cartridge pre filter 5 micron 26091 13 Cartridge carbon 2 each 26081 Flow Control 19 Control Flow 300ml RO 50 GPD 92610 19 Control Flow 400 ml RO 75 GPD 92611 Product Water Faucet 16 Faucet Standard 92609 ...

Страница 7: ...ers out suspended particles such as dirt or sediment The filtered water then enters the pre carbon filter 3 sump models only which contains granular activated carbon which removes any chlorine from the water The water then enters the reverse osmosis membrane The membrane will allow only permeate product water to pass through The brine waste water goes to the drain Permeate then flows through a hyd...

Страница 8: ...local government codes regarding installation of these devices must be observed Verify Water Supply is Potable The water supply must meet provincial state and or national standards for potable drinking water Water samples should be sent to a certified laboratory for analysis Placement of Components Placement of the various components of the system will vary from installation to installation The ma...

Страница 9: ...pacity and may increase lateral stress on the fittings causing leakage Fittings consist of two parts a Body and a colored collet and symbol Collet color and symbol corresponds to tubing to be used at that connection Figure 2 A To Insert Tubing 1 To install a tube push it through Collet until it seats firmly at bottom of fitting Figure 2 A and 2 B To Release Tubing 2 To remove a tube push and hold ...

Страница 10: ...r than the one serving the garbage disposal Before making a connection as shown in Figure 4 please check with code authorities Figure 4 Drain Saddle Assembly 7 Installation of Feed Water Assembly The system comes supplied with a saddle type valve with mounting hardware and is intended to be used on 3 8 to 1 2 copper tubing cold water supply line NOTE It is not to be used on flex lines a Turn off c...

Страница 11: ...Remove all burrs and sharp edges e Immediately clean up the sink area NOTE If an enamel or porcelain sink is encountered it is very important that the layer of porcelain be removed before following the steps outlined above This can be accomplished by gently grinding away using a hobby grinder and silicon carbide wheel enough area of porcelain down to the metal base to accommodate a 1 1 8 high spee...

Страница 12: ...to the selected location according to the surface finish a Rough or unfinished wood use two screws Item 2 b Smooth use double stick tape Item 3 Surface must be clean 3 Install Tubes onto AIRGAP body Item 4 Caution Do not use boiling water in this procedure Use hot water from the sink faucet only a Soak one end of each tube in hot water until the plastic becomes pliant b Push the tube Item 5 all th...

Страница 13: ...b or the palm of your hand push the membrane all the way into the housing Important Do not use force and ensure that the membrane is not protruding from the housing 6 Replace the membrane housing end cap and hand tighten 7 Push the tubing back into the quick connect fitting Ensure the tubing is all the way in Connecting Components Figure 8 Installing membrane without touching Figure 7 Front View a...

Страница 14: ...ide of the Pre Carbon Filter to the Auto Shut Off Valve Direct tubing into a pail or catch basin b Turn on the feed water by opening the needle valve on the feed water saddle valve and catch the water in the pail The water rinsing the filter will appear grayish until the fines are rinsed out When the water returns to clear close the inlet water valve Re connect the white tubing back into the Auto ...

Страница 15: ...ection of total dissolved solids in the water The membrane should be replaced every 24 to 36 months when its efficiency will decrease Post Carbon Filter The post filter contains a granular activated carbon Its function is to remove any taste and odor from the water prior to delivering it to the spigot The post filter cartridge should be replaced every 24 months Changing Filters Important This RO S...

Страница 16: ...onents DO NOT USE SCOURING PADS OR ANY OTHER TYPE OF INSTRUMENT THAT COULD POTENTIALLY SCRATCH THE SURFACES OF THE UNIT Measuring spoon or device Household bleach typically containing 5 25 of chlorine One 1 Gallon of potable water to mix up a disinfectant solution DO NOT USE WATER THAT IS NOT CONSIDERED POTABLE OR IS OF A QUESTIONABLE NATURE TO MIX UP THE DISINFECTANT SOLUTION Drip pan or catch ba...

Страница 17: ...ISINFECTED SURFACE Unless the membrane element is being replaced at this time then discard the old membrane STEP 4 OPEN THE FILTER SUMPS WITH THE SUMP WRENCH SUPPLIED AND REMOVE THE CARTRIDGES STEP 5 CLEAN THE FILTER SUMPS WITH SOAP AND CLEAN WATER USE A CLOTH OR SOFT BRUSH AS REQUIRED CLEAN THE INSIDE OF THE MEMBRANE HOUSING AS WELL You may need to pay close attention to the O Ring seals and re g...

Страница 18: ...10 ALLOW THE SYSTEM TO SIT WITH THE DILUTED SANITIZING SOLUTION FOR APPROXIMATELY 20 MINUTES STEP 11 OPEN THE FAUCET AND PURGE THE TANK AND SYSTEM OF THE SANITIZING SOLUTION STEP 12 REINSTALL THE MEMBRANE AND REPLACE THE CARTRIDGES PURGE THE PRE CARBON CARTRIDGE OF FINES as per installation instructions OPEN THE INLET SUPPLY NEEDLE VALVE AND ALLOW SYSTEM TO FILL OPEN THE FAUCET AND DISCARD THE FIR...

Страница 19: ...WCB 10 TFC RO Membrane Procedure 5 micron Sediment Carbon Cartridge 50 or 75 USGPD refer to Cartridge Rated Membrane instructions 3 sump models 3 sump models x2 refer to model all models Every 12 months Every 24 months 24 36 months Every 6 12 months The replacement frequency of the R O membrane is somewhat dependent on the feed water quality If the product water quality has decreased or the produc...

Страница 20: ...17 ...

Страница 21: ...18 Reverse Osmosis Drinking Water System Flow Diagram all models ...

Страница 22: ... feed water TDS Contact dealer for revised product water TDS 3 Membrane life expired Replace membrane Bad tasting water 1 Taste from glass or plastic containers Contact dealer for explanation 2 Post carbon filter cartridge exhausted Replace post carbon filter cartridge 3 Storage tank and or system contaminated Contact dealer for assistance 4 Membrane life expired Replace membrane Cloudy water 1 Di...

Страница 23: ...20 ...

Страница 24: ...part of this reverse osmosis unit because of misuse misapplication neglect alteration accident physical damage fouling and or scaling of membrane by dirt sediment minerals or bacteria attack installation or operation contrary to our printed instructions or damage caused by hot water freezing flood fire or Act of God is not covered by this warranty In all such cases regular parts and service charge...

Отзывы: