2
Certified Contaminant Reduction Performance
The following Economy Reverse Osmosis Systems conform to NSF/ANSI 58 for the specific performance claims as verfied and substantiated by
test data.
NOTES:
1. TFC refers to reverse osmosis membranes constructed from a THIN FILM COMPOSITE
2. The daily production rate is the volume of product water produced by the system per day and is determined by testing in accordance with the procedure outlined in NSF/ANSI Standard 58.
3. System’s Efficiency rating as verified by testing in accordance with NSF/ANSI standard 58. Efficiency rating means the percentage of the influent water to the system that is available
to the user as reverse osmosis treated water under operating conditions that approximate typical daily usage.
4. System’s Recovery rating as verified by testing in accordance with NSF/ANSI Standard 58. System’s Recovery rating means the percentage of the influent water to the membrane
portion of the system that is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed.
5. PRESSURE REGULATOR IS RECOMMENDED FOR FEED WATER PRESSURES EXCEEDING 552 kPa (80 psig)
Models & System Configurations
Conditions for Use
Item
Model
Storage
# of
Storage Tank
Vessel
Vessel
Vessel
Vessel
Daily Production
Efficiency
Recovery
Number
Description
Tank
Vessels Capacity Litres (gal)
1
2
3
4
Rate
(2)
L/day (G/day) Rating
(3)
% Rating
(4)
%
2885
RO,E50TFC-3NSF
Plastic
4
6 (1.6)
Sediment Filter Carbon Filter TFC
(1)
Membrane Carbon Filter
45.4 (12)
8.5
17.5
2886
RO,E75TFC-3NSF
Plastic
4
8.7 (2.3)
Sediment Filter Carbon Filter TFC
(1)
Membrane Carbon Filter
100 (26.4)
14.5
25.8
2887
RO,E50TFC-3NSF
Metal
4
8.3 (2.2)
Sediment Filter Carbon Filter TFC
(1)
Membrane Carbon Filter
45.4 (12)
8.5
17.5
2888
RO,E75TFC-3NSF
Metal
4
8.7 (2.3)
Sediment Filter Carbon Filter TFC
(1)
Membrane Carbon Filter
100 (26.4)
14.5
25.8
Source Water Supply Profile
Chemical Parameters
Max mg/L
Community/Private
Chlorinated/Non-Chlorinated
Hardness (CaCO
3
)
<350 (< 20 gpg)
Feed Water Pressure
(5)
242 – 690 kPa (35 – 100 psig)
Iron (Fe)
<0.1
Temperature
4° – 38°C (40° – 100°F)
Manganese (Mn)
<0.05
pH Range
3.0 – 11.0
Hydrogen Sulfide (H
2
S)
0.00
Maximum TDS Level
2000 mg/L
Residual Chlorine (Cl
2
)
<2.0
Turbidity**
<1.0 NTU
**Nephelometric Turbidity Unit
Maximum SDI***
<4.0
***Silt Density Index: Value stated in SDI units.
Models E50TFC-3NSF and E75TFC-3NSF
are tested and certified by WQA against
NSF/ANSI 58 for the reduction of TDS.
Содержание E50TFC-3NSF
Страница 20: ...17 ...
Страница 21: ...18 Reverse Osmosis Drinking Water System Flow Diagram all models ...