15
User Programming Mode Steps
Note:
Use
and
Down button to adjust values for parameters
1. Press the
and
buttons for five seconds while in service, and the time of day is NOT set to 12:01 PM.
2. Use this display to adjust the Day Override. Adjust this to OFF parameter for softeners.
3. Press the
button. Use this display to adjust the Regeneration Time.
4. Press the
button. Use this display to adjust the Feed Water Hardness in grains per gallon (gpg).
Hardness Compensation
1 mg/l of iron = 4 gpg
1 mg/l of manganese = 8 gpg
Maximum iron is not to exceed 1.5 mg/l total iron
Recommend the addition of a Res-up feeder when the total iron exceeds 0.5 mg/l
5. Press the
button. Use this display to adjust the Fixed Reserve Capacity. This option setting is
identified by “RC” in the upper left-hand corner of the screen. 75 gallons X # of people in the
house = RC
6. Press the
button. Use this display to set the Current Day of the Week. This option setting is
identified by “CD” in the upper left hand corner of the screen. This option is only available after the
Day of the Week control is set to ‘ON’ in the Master Programming. Refer to the valve manual for
details.
7. Press the
button to end User Programming Mode.
Programming Instructions
Set Time of Day
Press and hold or buttons until display reads TD
Adjust the displayed time with or buttons. Press to resume normal operation
Queuing a Regeneration
1. Press the button. The service icon will flash to indicate that a regeneration is queued.
2. To cancel a queued regeneration, press the button.
Regenerating Immediately
Press and hold the button for five seconds.
User Programming Mode Options
Abbreviation
Parameter
Description
DO
Day Override
The timer’s day override setting
THIS IS AN OPTION ONlY. PleASe DO NOT ADjUST BeFORe CONSUlTING AN AUTHORIzeD DeAleR.
RT
Regeneration Time
The time of day that the system will regenerate (meter delayed, timeclock, and day-of-week systems)
H
Feed Water Hardness The hardness of the inlet water - used to calculate system capacity for metered systems
RC
Reserve Capacity
The fixed reserve capacity
CD
Current Day
The current day of week
OFF
OFF
OFF
OFF
OFF
In the second level mode, the control valve has been pro-
grammed as per the following main parameters related to
regeneration. For more information on master programming
manual, read control valve manual part # 54802
The valve has been pre-programmed with factory settings
as shown in the following chart:
Regeneration Cycle Step Programming
1. Brine Rinse
60 minutes
2. Backwash
10 minutes
3. Rapid Rinse
10 minutes
4. Brine Refill
12 minutes
16 minutes
10 minutes
16 minutes
12 minutes
MXC75
MXC10
MXC125
MXC20
MXC30