background image

 

ACTIVATING THE SYSTEM 

CAUTION:

  Make sure all water supply lines, drain lines, and fittings are secure and free from leakage. 

 
1.  Open source water supply valve.  Close product water 

faucet.  Check for leakage. 

 
2.  Turn tank valve one-quarter turn counter- clockwise to 

open valve (handle should be in line with tubing as it 
enters connection). 

 
3.  Confirm system is producing water.  Module will be 

sending rinse water to drain. 

 

Optional Smartap

 Water Quality Monitor 

Perform Steps 4 - 7 

 
4.  Remove manifold cover if attached by gently lifting 

cover up and away from manifold.  

 

CAUTION:

  Wiring within module cover connects  

 

monitor components.  If wires, circuit board, or  

 

connections are damaged and/or wetted, monitor will  

 

not function.  

 
5. 

CAUTION: 

Verify battery connector alignment  

 

before making connection (Figure 9). 

 

Connect battery on manifold by pressing clip onto 
battery terminals. 

 
6.  Replace manifold cover by gently pushing cover onto 

manifold until it snaps into place. 

 
7.  Test battery connection by activating monitor.  Press 

push button.  If either indicator light illuminates, 
connection is good. 

 

NOTE: 

Release button after light illuminates.  Test is to 

confirm battery connection, not water quality. 

 
 

8.  Open product water faucet and let water flow until all air  
 

has been expelled from system.   
 

9.  Close product water faucet.  In 30 minutes, check 

connections for leaks and correct if necessary.  

 

Icemaker/Extra point of use: Check connections on 
these supply lines for leaks.  

 
10.  Allow storage tank to fill overnight.  
  
11. 

WARNING:  DO NOT USE THE FIRST FULL  

 

STORAGE TANK OF WATER

  

 

Discard (to drain) first full tank of water by opening 
product water (and extra point-of-use) faucet until water 
flow stops, then close faucet. This will flush sanitizing 
solution from system. 

 

Icemaker:  Let tray/bin fill with ice cubes.  Discard all  ice 
cubes.  This flushes sanitizing solution from lines to 
icemaker.   

 
12.  System is ready to use.  Should there be any aftertaste  
 

or odor to water or ice cubes, repeat Steps 10 and 11. 

 
 
 
 
 
 
 
 
 
 

DO NOT USE THE FIRST STORAGE TANK OF WATER 

Allow storage tank to fill overnight.  Dispense this water to drain. 

This process removes factory-installed sanitizing solution from the entire system and sends it to drain.   

This process also sanitizes fittings and tubing used during installation.

 

 

MAINTENANCE PROCEDURE PREPARATION 

 

RECOMMENDATIONS 

HAVE ALL EQUIPMENT AND REPLACEMENT COMPONENTS ON HAND AND READY BEFORE BEGINNING PROCEDURE. 

A CLEAN WORK AREA AND EQUIPMENT ARE ESSENTIAL TO PROPERLY CLEAN AND/OR SANITIZE THE SYSTEM. 

(i.e., CLEAN HANDS, TOOLS, WORK SURFACE, AND CONTAINERS) 

EQUIPMENT NEEDED 

  Safety glasses 

Rubber gloves, sanitary 

Wash Cloth, Clean and Lint-free 

Liquid dish soap 

Household bleach - Unscented Only 

       (5 1/4% sodium hypochlorite) 

Plastic storage bag 

Manual Air Pump 

Plastic bucket  

Plastic bowl 

“O” ring Lube FDA Approved 

 

 

Содержание 12403 series

Страница 1: ...ested and certified by WQA against NSF ANSI 58 for the reduction of TDS Tested and Certified by WQA against ORD0902 for lead free compliance 4VTFC09G PB 4VTFC50G PB 4VTFC25G PB 4VTFC75G PB WQA Tested...

Страница 2: ...on and retain for reference Unit Model Number _________________________________ Serial Number _____________________________________ Date Purchased ____________________________________ Date Installed _...

Страница 3: ...f this system The use of saddle piercing valves is not permitted The water produced by the reverse osmosis RO process can be used for many purposes around the home o Drinking Water keep a container of...

Страница 4: ...ers to reverse osmosis membranes constructed from a THIN FILM COMPOSITE 2 The daily production rate is the volume of product water produced by the system per day and is determined by testing in accord...

Страница 5: ...ICTOR TUBING 6 Flow Restrictor Tubing 9 GPD 25 GPD 50 GPD 75 GPD 40600034 40600040 40600041 40600042 PRODUCT WATER FAUCETS Item Description Part No 7 8 Chrome Plated Metal Air Gap Connector Faucet 3 8...

Страница 6: ...ER STORAGE TANKS ALL SYSTEMS Item Description Part No 1 2 3 4 Storage Tank Assembly Polymer Storage Tank Assembly Metal Ball Valve 3 8 Steel Tank Ball Valve 3 8 Plastic Tank Insert 3 8 92313 92342 922...

Страница 7: ...consideration are access to cold water supply line and household sink drainpipe Specific requirements are detailed in Table 3 COMPONENT LOCATION REQUIREMENTS Table 3 PRODUCT WATER FAUCET Faucet may b...

Страница 8: ...readings are obtained when the system is making water for at least 10 minutes The customer can also contact the local dealer for water sampling service or kit INTER COMPONENT CONNECTIONS Connections b...

Страница 9: ...4 Connect source water feed tubing to valve body using compression fitting a Slide nut and sleeve onto tubing in that order b Install insert into plastic tubing c Install tube with insert and sleeve...

Страница 10: ...tem 1 on drainpipe Allow adequate space for drilling operation 3 Tighten saddle bolts evenly on both sides Avoid over tightening 4 Using opening in drain saddle outlet as a guide drill a 3 8 to 7 16 d...

Страница 11: ...re pilot guide is inserted tightly Insert pilot guide into pilot hole Push down gently on drill motor to apply light pressure to porcelain surface Start drill motor turning as slowly as possible After...

Страница 12: ...hown 8 CAUTION Red 3 8 tube connecting product water faucet to drain saddle must run vertically or as closely as possible with no sharp bends or loops See Figure 4 Connect loose ends of tubing as foll...

Страница 13: ...not available in California 92192 1 2 3 4 5 6 7 8 Body Faucet Faucet Base Washer Rubber Faucet Base Washer Metal Washer Slotted Air Gap Slot Shape may vary Spacer Faucet Air Gap Washer Faucet Nut Fauc...

Страница 14: ...d Tape 25 GPD Yellow Casing Black Tape 50 GPD Yellow Casing White Tape 75 GPD Yellow Casing Blue Tape Cartridge Carbon AES 10 micron O Ring Filter Housing Housing Filter Circuit Board Battery 9 volt E...

Страница 15: ...et In 30 minutes check connections for leaks and correct if necessary Icemaker Extra point of use Check connections on these supply lines for leaks 10 Allow storage tank to fill overnight 11 WARNING D...

Страница 16: ...e water Inspect them for damage i e nicks scratches Replace damaged O rings 8 CAUTION Do not get Smartap Water Quality Monitor electronics wiring or connectors wet Clean filter housings and manifold p...

Страница 17: ...move battery by sliding it out of its holder 26 Slide new battery into its holder 27 CAUTION Verify battery connector alignment before making connection Figure 9 Connect battery by pressing clip onto...

Страница 18: ...factory drain storage tank sanitize system and replace membrane Drain storage tank and let it refill overnight LEAKAGE AND NOISE Symptom Probable Cause Solution Leak at fitting Tubing not pushed compl...

Страница 19: ...he drinking water system is altered by anyone other than WaterGroup the warranty shall be void ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICU...

Отзывы: