4
DRAIN OUTLET ASSEMBLY INSTALLATION
NOTE:
State, provincial and local plumbing codes may prohibit use of saddle-tapping drain connections and may
require use of an air gap.
NOTE:
Location and orientation of drain outlet assembly is vital to system performance.
Horizontal Drain Line:
Locate drain hole as close as possible to top of pipe
(between 45º and top) and as far as practical from
garbage disposal.
Vertical Drain Line:
Locate drain hole on a straight length of drainpipe next to
"P"/"S" trap between trap and sink.
Figure 4:
Drain Hole Location and Installation, Air Gap Faucet
1. Select a location for drain hole based on type of sink
and orientation of drain line (Figure 4).
NOTE:
Item callouts refer to Figure 5 unless noted
otherwise.
2. Position drain outlet saddle (Item 1) on drainpipe.
Allow adequate space for drilling operation.
3. Tighten saddle bolts evenly on both sides. Avoid
over-tightening.
4. Using opening in drain saddle outlet as a guide, drill a
3/8" to 7/16" diameter hole in drainpipe. Clean any
debris out of drain saddle connection.
Item
Description
Part No.
1
Drain Saddle, Air Gap, 3/8” Connection
92160
Figure 5:
Drain Outlet Assembly
Installation of Ball Valve Assembly on Plastic Storage
Tank
The ball valve and quick connect adapter must be
installed on the RO storage tank.
a. Install the 1/4" x 3/8" male connector onto the ball
valve.
IMPORTANT
-
Make sure to install the
‘INSERT’ in the 3/8” tubing before tightening the
nut of the ball valve.
Tighten the fitting very gently until it is snug.
Be very
careful not to over-tighten or the threads may strip.
b. Tighten the ball valve assembly onto the RO storage
tank. Tighten the fitting very gently until it is snug.
Be
very careful not to over-tighten or the threads may
strip.