Waterdrop M5 Скачать руководство пользователя страница 17

12

 

Check the tightness of the feed water adapter and make sure there is no water 

leakage.

 

When the quick-connect fitting leaks, do not replace only the lock clip. You must 

replace the entire quick-connect fitting.

 

Do not omit any lock clips.

 

Do not lay the system on its side, on its back, or upside down.

 

Do not use a filter that has not been flushed. Discard the first 4 tanks of water, 

then the fifth tank of water is drinkable.

 

Do not cut the tubing with tools other than a utility knife. Do not bend the tubing.

 

Use the new quick-connect fittings that come with the system. The old quick-

connect fittings cannot be reused.

 

Do not insert the drain tubing into the sewer. It must be connected to the 

drainpipe using the drain saddle.

 

 There is no filtered water in the tank

a. There is water inside the system: Turn off the feed water adapter and remove 

the tank. Tilt the system 45°and pour out the water inside. Turn on the feed water 

adapter to start up the system.

b. 

The water pressure is low: Check and confirm that the water pressure is between 

29 psi and 87 psi.

c.  A tubing is crimped: Check to ensure that all tubing is installed correctly and 

completely.

 

 The filtered water tastes bad

a. 

The filter has expired: Replace the filter according to schedule.

b. 

You have not used the system for a long time: Discard the remaining water in the 

tank and in the next tank of water.

c.  The water supply quality is poor: Make sure the water supply is municipal tap water.

 

 Abnormally low filtered water output

a. 

The filter is clogged: Flush or replace the filter. If you are using well water as 

the source, ensure that the feed water has gone through a pre-filtration system. 

Otherwise, large particles in the well water will easily clog the filter and shorten the 

filter life.

b. A tubing is crimped or there is a leak from the tubing connection: Check to ensure 

that all tubing is installed correctly and completely. 

c. 

The water temperature is low: Use the system at a temperature of 39-100°F.

Troubleshooting

 

 Water leakage

a. 

Check all the joints, fittings, and tubing connections to locate the leakage. Make 

sure the filter is well installed. 

Содержание M5

Страница 1: ...live chat available Reverse Osmosis Water Filtration System Countertop Instruction Manual Read and save these instructions M5...

Страница 2: ......

Страница 3: ...Countertop RO Installation on Visit warranty waterdropfilter com and enter the product serial number The serial number is the last 7 digits of the barcode on the cover plate and packaging box Any ques...

Страница 4: ......

Страница 5: ...Step 2 Connect the PE Tubing and the System Housing 5 Step 3 Install the Connector 6 Step 4 Install the Drain Saddle 7 Step 5 Connect the Inlet Water Tubing 7 Step 6 Start up the System 8 Owner s Manu...

Страница 6: ...moves organic matters chlorine taste and odor Further removes suspended matter and other impurities Improves the taste of water With a filtration accuracy of 0 0001 m it intercepts organic matters and...

Страница 7: ...ilter System Housing Base Tank Drain Saddle Connector Red 1 4 PE Tubing Thread Extension Stem Metal Gasket White 1 4 PE Tubing L Quick Connect Fitting Cable Tie Lock Clip X 1 Set X 1 Set X 1 Set X 118...

Страница 8: ...1 Remove the blue lock clip from the fitting 2 Use your thumb and index finger to press down on the lock sleeve Use your other hand to pull out the tubing from the fitting Figure 3 NOTE Please do not...

Страница 9: ...xcess water 2 Disconnect the cold water pipe from the cold water supply valve 3 Tighten the converter Twist the feed water adapter onto the cold water supply valve with its washer and tighten it using...

Страница 10: ...g out the plugs Connect the L quick connect fittings to the DRAIN and INLET ports Connect the white PE tubing to the INLET quick connect fitting connect the red PE tubing to the DRAIN quick connect fi...

Страница 11: ...the plastic nut of the connector and move the black gasket to the middle of the thread stem 2 Hold the white part of the connector with one hand and use the palm of the other hand to force it out fro...

Страница 12: ...hole of the foam seal is aligned with the hole of the front plate Choose a spot on the drainpipe that is convenient for installing the drain saddle Figure 9 NOTE It s recommended to install the drain...

Страница 13: ...let Water Tubing Connector Pressure Relief Valve Pressure Relief Valve Cold Hot NOTE Remove the cover plate before use Set the timer to the current month 1 Check and make sure all the PE tubing is ins...

Страница 14: ...mall amount of black water which is normal Flush it until the tank contains no black water or unpleasant odors Turn off the feed water adapter if you do not use the system for a long time If you want...

Страница 15: ...k of water is drinkable 1 Remove the cover plate 4 Put in the new filter and press the locking handle hard 2 Lift the locking handle 5 When you hear a snap and the locking handle stays in place the fi...

Страница 16: ...ime When the system is dispensing water there will be a slight vibration and noise which is normal This system is designed for indoor use only A floor drain should be located within 1 5 meters of the...

Страница 17: ...b The water pressure is low Check and confirm that the water pressure is between 29 psi and 87 psi c A tubing is crimped Check to ensure that all tubing is installed correctly and completely The filt...

Страница 18: ...ck of regular maintenance or improper use after delivery The cost of repair or replacement under those excluded circumstances shall be borne by the consumer This limited warranty does not cover the fo...

Страница 19: ...set forth herein are the only warranties we have made with respect to the product We make no warranties expressed or implied including but not limited to any warranties of fitness or merchantability...

Страница 20: ......

Страница 21: ......

Отзывы: