• Secure gland mount cap (2) to the replacement LED light by turning to the right and tighten
to ensure there is a water tight seal, and once again check “o” ring is proper fitting.
• Refit black power cable gland nut (11) and tighten to ensure proper sealing and locking the
gland mount cap (4) to correct position.
The replacement LED light is now ready to be refitted to the outer flange niche body (3) already
secured into the fibreglass pool wall. Ensure to carefully push the 1m coiled power cable into
the outer flange niche body (3) and refit the new replacement LED light assembly and secure
with the 2 screws (12).
Congratulations, reconnect power to your light at the circuit breaker and your new Waterco
replacement LED light is ready for use.
TROUBLE SHOOTING
FAULT
POSSIBLE CAUSE
REMEDY
Light not operating
- Fuse in transformer blown.
- No power to transformer.
- Fault in electrical wiring.
- Replace fuse.
- Check main fuses in switchboard.
- Electrician to check.
Light very dim and
pulsating
- Mismatch of lamp and
transformer ratings.
- Damaged wiring/ connectors.
- Fit correctly rated transformer*.
- Replace wiring/ connectors.
Main house fuse
blows when light
switched on
- Faulty transformer
- Damaged cable
- Incorrect electrical installation.
- Call electrician to check
installation.