background image

CITY

WATER

INLET

WELL

WATER

INLET

PRESSURE

TANK

PRE-FILTER

SYSTEM

EVO100

WATER

METER

PUMP

SERVICE

Relief Valve

MUST

 be 

Installed

Grounded & 

Unswitched

115-Volt Outlet

OF

F

OF

F

PRODUCT SPECIFICATIONS

PERFORMANCE

WHERE TO INSTALL

Installation  . . . . . . . . . . . . . . . . . . Whole House

Particle Retention Size   .   .   .   .   .   .   .   .   .   .   .   .   . Sub-Micron

Intelligent Monitor. . . . . . . . . . . . . . . . . . . . LED

Rated Capacity  .   .   .   .   .   .   .   .   100,000 gallons (378,541 L)

Rated Service Flow   . . . . . . . . . . . . . . .  4.51 gpm

Peak Flow & Reduction of Lead  . . . . . 8 gpm @ 99.62%

Replacement Filter Cartridge . . . . . . . . . . . . . EVR1

Maximum Working Pressure  . . . . 125 psig (8.89 kg/cm

2

)

Minimum Working Pressure  . . . . . 20 psig (1.41 kg/cm

2

)

Maximum Operating Temperature  . . . . . . 120˚ F / 50˚ C

Minimum Operating Temperature. . . . . . . . .34˚ F / 1˚ C

Electrical Requirements. . . Grounded & Unswitched 115V,

              

3-AAA Batteries

WATERCHEF

®

 WHOLE HOUSE WATER FILTRATION SYSTEM

 

(Model: EVO100)

Refer to Performance Data Sheet for actual contaminant and substance reduction capabilities.

Manufacturer internally tested for 

Chlorine and Chloramine reduction.

waterchef.com

3

This system has been certified by IAPMO for NSF/ANSI Standard 53 and CSA B483.1 for the specific  

performance claims verified and substantiated by test data. Actual performance is dependent on influent  

water quality, flow rates, system design and applications. Your results may vary. Performance claims are 

based on a complete system, including filter cartridge, housing, and connection to a pressurized water 

source. This filter must be operated according to the system’s specifications in order to deliver the claimed 

performance. It is essential to follow operational, maintenance, and filter replacement requirements, as  

directed for each application, for this filter and system to perform correctly. Read the Performance Data 

Sheet accompanying the system and change the filter cartridge as suggested.

System Certified by IAPMO R&T against NSF/ANSI 

Standard 53 and CSA B483.1 for the reduction of 

Lead, Cysts, Perfluorooctanoic Acid (PFOA) and 

Perfluorooctane Sulfonate (PFOS).

Содержание EVO100

Страница 1: ...er Filtration System Read SaveThese Instructions IMPORTANT QUESTIONS 1 800 879 8909 int l 1 775 359 9500 MON FRI 8 AM 5 PM PST My System Serial Serial Number is located on filter housing base System Certified by IAPMO R T against NSF ANSI Standard 53 and CSA B483 1 for the reduction of Lead Cysts Perfluorooctanoic Acid PFOA and Perfluorooctane Sulfonate PFOS ...

Страница 2: ...O100 Filter Housing Assembly includes Top Cap and Snap Ring WaterChef EVR1 Filter Cartridge Flow Control Valve Reducer Tees 2 Flow Meter Assembly Straight 1 MNPT Connectors 2 90º Elbow 1 MNPT Connectors 2 3 8 Drain Valve Assembly with Shut off Umbrella Cover with Monitor Assembly and Battery Backup Power Supply Also Included Food Grade Silicone AAA Batteries 3 3 8 O D Drain Hose 5ft Installation U...

Страница 3: ...ppliances downstream or potential galvanic activity in the plumbing system can no longer ground through contiguous metal plumbing Some homes may have been built in accordance with building codes that actually encouraged the grounding of electrical appliances through the plumbing system Consequently the installation of a bypass consisting of the same material as the existing plumbing or a grounded ...

Страница 4: ... Manufacturer internally tested for Chlorine and Chloramine reduction waterchef com 3 This system has been certified by IAPMO for NSF ANSI Standard 53 and CSA B483 1 for the specific performance claims verified and substantiated by test data Actual performance is dependent on influent water quality flow rates system design and applications Your results may vary Performance claims are based on a co...

Страница 5: ...nnecting your plumbing system Hand Tighten Only 5 Install Drain Valve Assembly 7 into left Reducer Tee 3 using the threaded connection and plumber s tape Hand Tighten Only 6 Install 3 AAA batteries in Umbrella Cover 8 connect to power supply Filter Housing Bottom Inlet Outlet Cap Assembly Reducer Tees 2 1 plugged fitting Flow Meter Assembly Flow Control Valve 6 Straight or 90º Elbow 1 MNPT Connect...

Страница 6: ...e bottom of the Tank Press down on the Cartridge so that the double O ring seats into the bottom center opening fig D 5 Reposition the Top Cap into its original location on the Housing 6 Reattach the Snap Ring then pull up on the Top Cap handles to seat the O ring 7 Turn water supply ON by opening the Inlet Outlet Valves on the Flow Control Valve 8 As the System fills with water push down on the R...

Страница 7: ...efully grasping the handle and pulling inward then upward The Ring should slide completely out of the groove fig J 5 Remove the Top Cap from the Housing by lifting up on the Cap Handles Remove the old Filter Cartridge 6 Connect 3 8 O D Tubing included with EVO100 System to the Drain Valve that connects to the inlet side of the Filtration System Run the hose to a floor drain or bucket then OPEN the...

Страница 8: ...ain Valve then turn ON the water supply to the System by opening the Inlet Outlet Valves on the Flow Control Valve 12 As System fills with water push down on the RED Pressure Release Button on Top Cap to relieve System of air fig M Keep Button pushed down until ALL air is released and water starts to come out of the Button Release Button 13 Seat Umbrella Cover on top of Housing Assembly fig N and ...

Страница 9: ...ollowing pattern 1 2 3 2 repeat The frequency that the LEDs blink corresponds to the flow rate received from the Monitor For every revolution from the Monitor the LED pattern should be incremented to turn off the next LED If there are no revolutions for 2 seconds all LEDs will turn on solid If the batteries are low the middle LED will turn WHITE The battery level is checked once an hour to minimiz...

Страница 10: ... water pressure that is outside the specified operating range Damage caused by accident fire freezing flood or acts of God Cost of labor or expenses expended in the installation and or removal of system filter cartridges or any surrounding device Incidental or consequential damage caused by a failure of the product or the breach of any expressed or implied warranty Except to the extent prohibited ...

Страница 11: ...u may complete and return this registration form to WaterChef Customer Care 3760 Barron Way Reno NV 89511 NAME STREET ADDRESS CITY STATE ZIP PHONE EMAIL MODEL EVO100 SERIAL DATE OF PURCHASE PURCHASED FROM Sign me up for WaterChef Updates Special Promotions Exclusive Discounts Please send me Courtesy Email Notifications when it s time to replace my filter cartridge We value your privacy and will no...

Страница 12: ...1 404 0122 r19 10 WaterChef 3760 Barron Way Reno NV 89511 tel 1 800 879 8909 int l 1 775 359 9500 email customercare waterchef com web waterchef com ...

Отзывы: