STARTUP INSTRUCTIONS

FLUSHING OF SYSTEM:

To flush the system of any debris and air after installation is complete, please perform the following steps:

 

1. Rotate bypass handles to the bypass mode 

(see Fig. 2 of page 4).

 

2. Turn on inlet water and check for leaks in the newly installed plumbing.

 

3. Fully open a cold water faucet, preferable at a laundry sink or bathtub without an aerator.

 

4.  Wait two to three minutes or until water runs clear, then turn water off and follow start-up instructions.

 

System regeneration sequence is in the following order. Some sequence differences may be noticed depending upon

local conditions. (If it is desired to change this sequence, please contact the manufacturer.)

    

Sequencing for Various Filters:

Air Filters (Iron & Sulfur) 

 

1. Backwash Air

2. Backwash 

 

 

3. Regenerant Draw Down (Air draw)  

 

 

 

4. Return to service 

 

 

Inch Worm Feature:

Air filter units are programmed with the backwash air cycle 

feature (nicknamed “inch worm”). This unique feature allows 

for small movements or “inching” of the piston towards 

the backwash cycle. As the piston approaches this cycle, 

the backwash port opens slightly with each advancement, 

allowing air to escape to drain. This cycle is twelve very small 

mini steps of the piston which take place twenty seconds 

apart. Usually midway between the twelve positions, the 

air begins to be released very slowly to the drain in normal 

operating conditions.

When first starting up an air sulfur or air iron, it is advised to 

step through these positions and go to the normal backwash 

cycle in order to fill the unit. 

To Advance in Backwash Air Cycle:

1.  Pushing the 

����

 button will advance to each of the twelve 

mini steps within the backwash air cycle. While there are 

usually twelve steps to this cycle, the valve may make two or 

three movements for each step. Wait for these movements 

to complete before pressing 

����

 again.

2.  Pushing and holding the 

����� 

button for three seconds 

while in the Backwash Air cycle will skip the remaining mini 

steps and proceed to the next cycle of regeneration which 

is usually Backwash.

The system is now ready for filling with water and for testing for Air Filters.

 NOTE: The “filling” sequence below represents the start-up procedure for Air Filters.

Please reference “Sequence for Various Filters” for proper regeneration sequence (shown above).

1.   Place the bypass valve into the bypass mode 

(Fig. 2 on page 4).

2.   Press and hold the 

�����

 button until the motor starts. Release button. Put the valve into “BACKWASH” position.

(Please see note above.) Unplug the transformer so that the valve will not cycle to the next position. Open the

inlet handle of the bypass valve very slightly allowing water to fill the tank slowly in order to expel air.

CAUTION:

  If water flows too rapidly, there will be a loss of media to the drain.

Certain medias such as carbon, or other dry medias, should not be backwashed immediately for extended periods of time. These 

medias need to “soak” in the water for a 24-hour period prior to full backwash conditions. 

Dry media exposed to water too quickly in backwash will result in media plugging the drain and valve assembly. 

3.  After the water is flowing steadily to the drain, clear and without the presence of air, slowly open the inlet valve. Restore power and 

momentarily press the 

�����

 button to advance the control to the “REGENERANT DRAW DOWN” position.

4.  With the bypass still in the diagnostic mode 

(Fig. 3 on page 4)

, there should be a slow flow to the drain.

5.   Press 

�����

 button in sequence until display returns to “TIME.” Place bypass valve in the normal operating mode 

(Fig. 1 on page 4)

 by opening the outlet bypass handle.

6. 

CONDITIONING OF MEDIA:

  To flush any remaining debris and air from the system again:

  1. Turn on a cold water faucet wide open, preferably at a laundry sink or bathtub without an aerator.

  2. Wait two to three minutes or until water runs clear, then turn water off.

  3. Turn on hot water and check for air, then turn water off after air is discharged.
7. Place unit into regeneration and allow to complete a full cycle. Upon completion, unit will deliver treated water. 

Содержание Ion ProSeries

Страница 1: ...Installation Instructions Owner s Manual Ion Pro and CareClear Pro Series Water Filters For Models IPHS IPFE IPG IPCG AN CCP CCP AN...

Страница 2: ...__________________ yes no Total Dissolved Solids_____________ Over 10 ppm may be harmful for human consumption Water conditioners do not remove nitrates or coliform bacteria this requires specialized...

Страница 3: ...rate capacity remaining days to a regeneration and vacation mode are optional displays For more explanation consult the operating displays and maintenance section Pressing the NEXT button on a general...

Страница 4: ...es point in the direction of flow indicated by the engraved arrows on the control valve Water flows through the control valve for normal operation of a water softener or filter During the regeneration...

Страница 5: ...vacuum breaker in the installation 6 INLET OUTLET PLUMBING Be sure to install Bypass Valve onto main control valve before beginning plumbing If it is desired to bypass outside hydrants a cold water ki...

Страница 6: ...drainage system or other safe location Remember to follow all local codes When installing the drain line on any backwashing filter especially filters that utilize air as the regenerant hard piping su...

Страница 7: ...y to relieve the pressure from the system Place filter into by pass mode Fig 2 Page 4 and release pressure by manually stepping through an entire regeneration sequence This will adequately release the...

Страница 8: ...apacity has been met Note This valve has the capability of regenerating up to six times in one day This can be set by pressing the CLOCK and buttons simultaneously on the DAYS BETWEEN REGEN screen Use...

Страница 9: ...Press the or buttons to select the hour when the buzzer should begin sounding AM PM toggles after 12 Default setting is 6 00 a m BUZZER STOP TIME Press the or buttons to select the hour when the buzze...

Страница 10: ...ckwash Air cycle will skip the remaining mini steps and proceed to the next cycle of regeneration which is usually Backwash The system is now ready for filling with water and for testing for Air Filte...

Страница 11: ...ter meter is installed GPM flashes on the display when water is being treated indicating gallons per minute flowing through the system 2 VACATION MODE This feature may be used to shut down the system...

Страница 12: ...th the valve unplugged to avoid causing a short and potentially ruining the board 6 Reset the time of day see programming procedures and initiate regeneration see operating displays and maintenance If...

Страница 13: ...nside the tank Pay close attention to media level when filling see diagram Do not overfill The additional media added should not be higher than two thirds of the tank height when measuring from the bo...

Страница 14: ...ned water tap and flush until clear For Acid Neutralizers With the 100245758 CD1220 In Out Head With Fill Port 1 Check the media height by shining a flashlight through the tank to see the height of th...

Страница 15: ...B Connect meter to three pin connection labeled METER on PC board C Restricted stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into...

Страница 16: ...debris and if necessary replace H Damaged seal stack assembly piston H Replace seal stack assembly and or piston I Control valve body type and piston type mix matched I Verify proper control valve bod...

Страница 17: ...n the PC board labeled MOTOR Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect B PC bo...

Страница 18: ...V NHBP motor to PC board two pin connection labeled DRIVE Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 secon...

Страница 19: ...ory screens These do not flash when error occurs A Occurs when dP input is active for ALARM and the input is closed The alarm buzzer will activate and the screen will display the error A Check for low...

Страница 20: ...Soft Elite CareSoft Pro cover blue buttons 1 2 CV3107 1 100246273 Motor Assembly 1 3 CV3002 A 100246193 Drive assembly includes 5 and 6 4 CV4050WX 02 100246447 PC board 1 CV4237YB BOARD 100246452 PC b...

Страница 21: ...generant piston 1 6 CV3001 04 100244557 1 body assembly downflow 1 CV3001 04UP 100243827 1 body assembly upflow 1 CV3020 100246239 1 25 body assembly downflow 1 7 CV3541 100249867 Drive backplate 1 No...

Страница 22: ...e assembly 1 Loosens Injector And Bypass Caps Loosens Drive Cap BYPASS VALVE Item Current Part Description Qty 1 100249845 Bypass assembly 1 Although no tools are necessary to assemble or disassemble...

Страница 23: ...221 Injector assembly plug 1 5 100246215 F injector assembly 100246216 G injector assembly The injector plug and the injector each use one lower and one upper O ring REPLACEMENT PARTS 3 1 2 WATER METE...

Страница 24: ...1 elbow 5 100243824 FTG Drain 1 Strt No Silencer requires DLFC 1 REPLACEMENT PARTS Water flow Proper DLFC orientation directs water flow towards the washer face with rounded edge 2 3 8 5 7 6 1 DRAIN L...

Страница 25: ...ription Qty 100245758 1190 In Out Head W Port 1 Not Shown 100246307 Base O Ring 1 100246272 Distributor Pilot O Ring 215 1 100246281 O Ring Fill Cap 1 4 43 112 4 OZONE GENERATOR Item Current Part Desc...

Страница 26: ...100246200 3 4 john guest elbow assembly 2 Legacy Part Current Part Description Qty CV3007 17 100245045 1 john guest assembly 2 Legacy Part Current Part Description Qty CV3007 09 100243922 1 1 4 1 1 2...

Страница 27: ...99 129 4 150 IPFE 1054 IPFE 1252 IPFE 1354 Birm 1 0 Birm 1 5 Birm 2 0 14 lb 1 4 x 1 8 7 lb 20 14 lb 1 4 x 1 8 7 lb 20 21 lb 1 4 x 1 8 7 lb 20 5 0 6 0 7 0 18 0 19 0 19 0 5 3 9 0 10 0 5 0 5 0 5 0 1 0 1...

Страница 28: ...N A N A N A N A N A N A N A 10 W x 50 H 10 W x 60 H 13 W x 60 H 63 90 66 135 84 225 MODEL CCP 1044 CCP 1054 CCP 1354 Mineral Type Amount Cu Ft Carbon 1 0 Carbon 1 5 Carbon 2 5 Gravel Amount Size No 1...

Страница 29: ...freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes and in an equivalent manner and condition of the original instal...

Страница 30: ...and TIME OF DAY will flash alternately if a regeneration is expected tonight TREATED WATER EXITS SUPPLY WATER ENTERS SUPPLY WATER EXITS SUPPLY WATER ENTERS NORMAL OPERATION BYPASS OPERATION ERROR 106...

Страница 31: ...n simultaneously 2 Adjust days between regenerations using and buttons 3 Press 4 Adjust time of regeneration hour with and buttons AM PM toggles at 12 5 Press 6 Adjust time of regeneration minutes wit...

Страница 32: ...100248125 2000592008 RevA0422 Manufactured exclusively for WaterCare Dealers at 1900 Prospect Court Appleton WI 54914 Phone 920 739 9401 Fax 920 739 9406 Love your WaterCare filter Scan the QR code a...

Отзывы: