How to Install the Tank

Step  I:  Disconnect  and  remove  the  exist-

ing  tank  after  turning  the  power  off  and 

draining the system.

1. 

Find  the  fuse  box  or  circuit 

breaker  panel  for  your  house. 

Turn  off  the  power  to  the  well 

pump.

For your safety, 

the  information 

in  this  manual  must  be  followed 

to  minimize  the  risk  of  electric 

shock,  property  damage,  or 

personal  injury.  Properly  ground 

to  confirm  with  all  governing 

codes and ordinances.

2. 

Open  a  faucet  inside  the  house. 

Drain  the  system  as  much  as 

possible  by  letting  the  water  run 

until it runs out.

3. 

Close  the  ball  or  gate  valve  (this 

is  the  valve  that  controls  the 

flow  of  water  from  the  tank  into 

the  plumbing  system  inside  the 

house) 

(Fig. 1)

4.  Drain  the  remaining  water  from 

the  tank  with  a  garden  hose  into 

a  bucket  or  floor  drain.  Attach 

a  garden  hose  to  the  faucet  on 

the front of the tank cross. Place 

the  other  end  of  the  hose  in  a 

bucket so that it is at a level lower 

than  the  faucet.  Open  the  drain 

valve  and  drain  the  water  out  of 

the  tank.  It  may  be  necessary 

to  vent  the  tank  through  the 

air  valve  to  allow  the  tank  to  

drain completely. 

(Fig. 2)

5. 

Disconnect  the  wiring  to  the 

pressure  switch. 

(Check  first  to 

be  sure  that  the  power  to  the 

pump is turned off.)

a. 

Loosen  the  hex  nut  on  the  top 

of  the  cap  using  pliers  or  an 

adjustable  wrench.  Unscrew  by 

hand. 

(Fig. 3)

b.  Remove  the  cap  to  the  pressure 

switch.

c. 

Unscrew  the  connections  for  the 

wires.

d.  Mark  which  wire  goes  to  which 

screw on the pressure switch (i.e. 

note that the green wire connects 

to  the  front  screw;  mark  using 

masking  tape  if  necessary). 

(Fig. 

4)

e. 

Unscrew  the  clamp  connector 

holding the wiring to the pressure 

switch. 

(Fig. 5)

f. 

Pull the wires out of the pressure 

switch. 

(Fig. 6)

6.  Loosen  and  unscrew  the  union 

connections  that  hold  the  tank 

and  the  tank  cross/pressure 

gauge/pressure  switch  assembly 

in place. 

(Fig. 7-8)

7. 

Lay the tank on its side with tank 

cross  pointing  up.  Remove  tank 

cross  assembly  by  unscrewing  it 

using the pipe wrench. 

(Fig. 9)

Step II: Assemble the new tank cross unit.

 

NOTE:

 If you are re-using the tank cross assembly from the old 

tank skip to Step III.

1. 

If  you  are  using  new  parts  for 

the  tank  cross  assembly,  remove 

the  new  tank  cross,  pressure 

gauge,  pressure  switch,  pressure 

relief valve, and pipe nipple from  

their packages.

 

Assemble  the  tank  cross  unit. 

Apply  Teflon

®

  tape  to  the  male 

threads  on  the  tank  cross 

pressure  gauge  and  both  ends 

of the pipe nipple. 

(Fig. 10) 

Apply 

clockwise  (i.e.  bottom  up  and 

coming towards you). Apply 3 full 

turns.

2. 

Insert  the  pipe  nipple  into  one 

of  the  holes  on  the  top  of  the 

“crossbar”  of  the  tank  cross. 

(It  doesn’t  matter  which  one.) 

Tighten  using  the  pipe  wrench. 

(Fig. 11)

3. 

Insert  the  pressure  gauge  in  the 

other hole on top of the crossbar. 

Tighten  using  the  adjustable 

wrench  on  the  square  brass  nut. 

Tighten  hand  tight,  then  wrench 

tight.  Do  not  over  tighten. 

The  Teflon

®

  tape  will  ensure  a 

sufficient  seal.  Once  tightened, 

do not loosen. If you do, the joint 

is more likely to leak. 

(Fig. 12)

4.   Install the pressure switch on the 

top  of  the  pipe  nipple.  Again, 

tighten  using  the  adjustable 

wrench  on  the  hexagonal  brass 

nut.  Tighten  hand  tight.  Then 

wrench tight.

5. 

Install  drain  on  the  arm  of  the  

cross bar of the tank cross. Tighten 

using pipe wrench. 

(Fig. 13)

A  drip  pan 

c o n n e c t e d 

to  an  adequate  drain  must  be 

installed  if  leaking  or  flooding 

could cause property damage to 

the area adjacent to the appliance 

or to lower floors of the structure.

6.  Install  the  pressure  relief  valve 

in  the  other  female  threaded 

opening on the front of the cross 

bar of the tank. 

(Fig. 14)

 

Always be sure 

to  equip  your 

well  system  with  a  proper 

pressure relief valve.

Step  III:  Install  the  new 

tank cross assembly on the new tank

.

1.   Remove the plastic plug from the 

elbow at the bottom of the tank. 

Discard the plug.

2.   Install  the  tank  cross  assembly 

on  the  tank.  Either  use  the  new 

tank cross assembly, put together 

according  to  Step  II  above,  or 

reuse  the  tank  cross  assembly 

from the old tank.

3.   Apply Teflon

®

 tape to the threads 

at  the  bottom  of  the  “stem”  of 

the  tank  cross.  Insert  the  stem 

in  the  female  threaded  fitting  on 

the  bottom  of  the  tank.  Tighten 

hand  tight  then  wrench  tight. 

(Fig. 14-15)

1

2

3

4

5

6

7

8

9

10

Содержание HT14B

Страница 1: ...r performance d If you have a jet pump remove the fittings and plug the openings where the vacuum or air lines and air volume controls connect to the pump or piping If not removed and plugged they can...

Страница 2: ...the new tank cross unit NOTE If you are re using the tank cross assembly from the old tank skip to Step III 1 If you are using new parts for the tank cross assembly remove the new tank cross pressure...

Страница 3: ...from the factory Release or add air to adjust the pressure properly If the charge is too high release some air by pressing down on the pin inside the air valve If the charge is too low pump it up usi...

Страница 4: ...sional regarding any steps you may wish to take to safely disinfect your home s plumbing system DANGER EXPLOSION HAZARD WHEN THE WELL TANK HAS BEEN IN SERVICE AND A CHANGE TO A HIGHER PRE CHARGE PRESS...

Страница 5: ...a WATER WORKER authorized distributor or retailer more than 30 days after expiration of the applicable warranty time period described in this Warranty this Warranty also does not cover repair or repla...

Страница 6: ...pe jet enlevez les raccords et bouchez les ouvertures l o la tuyauterie vide ou air comprim et l o les commandes de volume d air se raccordent la pompe ou la tuyauterie S ils ne sont pas enlev s et le...

Страница 7: ...ape II assemblez le nouveau bloc croisillon du r servoir REMARQUE si vous r utilisez le bloc croisillon de l ancien r servoir passez l tape III 1 Si vous utilisez de nouvelles pi ces pour le bloc croi...

Страница 8: ...ez ou ajoutez de l air pour bien ajuster la pression Si cette charge est trop lev e laissez chapper un peu d air en appuyant sur la broche l int rieur du robinet d admission d air Si la charge n est p...

Страница 9: ...suivre pour d sinfecter s curitairement votre plomberie r sidentielle DANGER RISQUE D EXPLOSION LORSQUE LE R SERVOIR POUR PUITS A T EN SERVICE ET QU UN CHANGEMENT UNE PRESSION DE PR CHARGE SUP RIEURE...

Страница 10: ...R un distributeur ou un d taillant autoris WATER WORKER plus de 30 jours apr s l expiration de la p riode de garantie d crite dans la pr sente garantie La pr sente garantie ne couvre pas les co ts de...

Страница 11: ...da ar el sistema y afectar el rendimiento d Si tiene una bomba de chorro quite los accesorios y tape las aperturas donde las l neas de vac o o aire y los controles del volumen de aire se conectan con...

Страница 12: ...aso II Monte la unidad cruzada del tanque nuevo NOTA Si vuelve a usar el ensamblaje cruzado del tanque viejo vaya al paso III 1 Si usa piezas nuevas para el ensamblaje cruzado del tanque saque el cruc...

Страница 13: ...tanque se env a de f brica Libere o agregue aire para ajustar la presi n de forma adecuada Si la carga es demasiado alta libere una parte del aire presionando hacia abajo el perno dentro de la v lvula...

Страница 14: ...a su plomero profesional local acerca de los pasos que puede tomar para desinfectar de forma segura el sistema de tuber as de su hogar PELIGRO PELIGRO DE EXPLOSI N SI SE HA REALIZADO EL SERVICIO T CN...

Страница 15: ...ER un minorista o un distribuidor autorizado de WATER WORKER despu s de los 30 d as del per odo de tiempo de vigencia de la garant a descrita aqu Esta garant a tampoco cubre los costos de reparaci n n...

Страница 16: ...16...

Отзывы: