background image

Water Specialist WS2H and WS3

Control Valve Drawings and Service

Manual

HYDROCARBONS SUCH AS KEROSENE, BENZENE, GASOLINE, ETC., MAY 

DAMAGE PRODUCTS THAT CONTAIN O-RINGS OR PLASTIC COMPONENTS. 

EXPOSURE TO SUCH HYDROCARBONS MAY CAUSE THE PRODUCTS TO 

LEAK. DO NOT USE THE PRODUCT(S) CONTAINED IN THIS DOCUMENT ON 

WATER SUPPLIES THAT CONTAIN HYDROCARBONS SUCH AS KEROSENE, 

BENZENE, GASOLINE, ETC.

Содержание WS2H

Страница 1: ...AS KEROSENE BENZENE GASOLINE ETC MAY DAMAGE PRODUCTS THAT CONTAIN O RINGS OR PLASTIC COMPONENTS EXPOSURE TO SUCH HYDROCARBONS MAY CAUSE THE PRODUCTS TO LEAK DO NOT USE THE PRODUCT S CONTAINED IN THIS...

Страница 2: ...Page 2 WS2H and WS3 Drawings and Service Manual...

Страница 3: ...Assembly 19 Brine Valve Body and Injector Components 20 Base Tank Adapters 21 V3158 04 2 Drain Elbow Male NPT without silencer 22 V3008 05 2 Drain Fitting 1 Straight Male NPT without silencer 23 V307...

Страница 4: ...ccuracy Flow Range WS2H Valve Internal Meter 5 1 5 125 gpm 5 7 473 lpm WS3 Valve Optional External Meter 5 3 5 350 gpm 13 3 1325 lpm Regenerant Refill Rate WS2H and WS3 Valves Variable Shipped from Fa...

Страница 5: ...1 or 1 13 24 VAC V34612 WS2H 3 AC ADAPTER V3461EU WS2H 3 AC ADAPTER EU V3461UK WS2H 3 AC ADAPTER UK 20 VAC3 V3461 01 WS2H 3 AC ADAPTER 20V V3461EU 01 WS2H 3 AC ADAPTER EU 20V V3461UK 01 WS2H 3 AC ADAP...

Страница 6: ...Page 6 WS2H and WS3 Drawings and Service Manual BRINE REFILL DRAIN INLET OUTLET INTERNAL FLOW METER BRINE REFILL OUTLET DRAIN INLET Installation WS2H CONTROL VALVE TOP VIEW WS3 CONTROL VALVE TOP VIEW...

Страница 7: ...ds Use of pipe dope may break down the plastics in the control valve When servicing the valve water may leak from the valve Water from the valve may create a slip hazard Clean up water spills Disconne...

Страница 8: ...ve the control valve where possible Discharge the drain line through an air gap to a receptacle in accordance with local plumbing codes IMPORTANT Never insert a drain line directly into a drain sewer...

Страница 9: ..._______________________ Installer s _______________________________________________ Phone Number ____________________________________________ Application Type Softener _______ Other __________________...

Страница 10: ...and WS3 Drawings and Service Manual WS2H Control Valve Cycle Positions SERVICE BACKWASH Treated Water Supply Raw Water Inlet Raw Hard Water is bypassed during regeneration Backwash water to drain Raw...

Страница 11: ...ssed during regeneration Regenerant water to drain Raw Water Inlet Regenerant solution being drawn in Injector feed water from Raw Water Inlet supply Raw Hard Water is bypassed during regeneration Slo...

Страница 12: ...NSE SOFT WATER REFILL Rinse water to drain Raw Water Inlet Raw Water Inlet Raw Hard Water is bypassed during regeneration Treated Water Supply Refill port to refill tube for treated water Treated Wate...

Страница 13: ...Drawings and Service Manual Page 13 WS3 Control Valve Cycle Positions SERVICE BACKWASH Treated Water Outlet Raw Water Inlet Raw Water Inlet Raw Hard Water is bypassed during regeneration Backwash Wat...

Страница 14: ...ard Water is bypassed during regeneration Backwash Water to Drain Regenerant solution being drawn in Injector feed water from Raw Water Inlet supply Raw Water Inlet Raw Hard Water is bypassed during r...

Страница 15: ...NSE SOFT WATER REFILL Raw Water Inlet Raw Hard Water is bypassed during regeneration Rinse Water to Drain Raw Water Inlet Treated Water Supply Treated Water to Regenerant Tank Treated water from Refil...

Страница 16: ...ASY 1 8 V3110 WS1 DRIVE GEAR 12X36 3 9 V3109 WS1 DRIVE GEAR COVER 1 Not Shown V3461 WS2H 3 AC ADAPTER shipped less cord 1 See Table 2 Software and Power Supply Compatibility for option selection V3461...

Страница 17: ...1 18 V3276 WS2H 3 BOLT HEX SS 5 16 18X1 3 4 1 19 V3269 WS2H 3 NUT 5 16 18 SS HEX 1 Not Shown D1300 01 TOP BAFFLE DFSR CLACK 2 63MM 1 In 2008 a modification was made to Meter Housings to use V3632 WS1...

Страница 18: ...344 1 6 V3666 01 WS3 PISTON 1 7 V3238 01 WS2H 3 BRINE PISTON 1 8 V3092 WS3 STACK ASY 1 Not Shown V3468 WS2H 3 PLUG 1 4 HEX NPT included when ordering V3667 03 2 V3465 WS2H 3 PLUG 1 4 HEX BSPT included...

Страница 19: ...AXIMUM OPERATING TEMPERATURES 40 F MINIMUM 110 F MAXIMUM CLACK CORPORATION VALVES ONLY V3221 WIRE HARNESS RED WHITE BLACK RED AND WHITE LEADS NOT INSERTED IN HOUSING BLACK V3095 WS3 Meter NPT MxF Asse...

Страница 20: ...R ASY G V3010 2H WS2 2H 3 INJECTOR ASY H Not Shown V3499 WS2H 3 FITTING CAP 1 IN THREADED 1 1 Not Shown V3797 WS1 FTG 1 PVC MALE BSPT ELBOW BSPT Only BSPT Only V3236 04 WS2H INJECTOR TUBE ASY A thru H...

Страница 21: ...8X2 SS 12 12 2 V3293 WS2H WASHER SS 5 16 FLAT 24 24 3 V3445 WS2H WASHER SPLIT LOCK 5 16 SS 12 12 4 V3447 WS2H NUT HEX 5 16 8 FULL SS 12 12 5 COR60FL O RING 6 FLANGE ADAPTER 1 1 6 V3261 01 WS2H FLANGE...

Страница 22: ...S1 DLFC 1 3 gpm for 3 4 V3162 017 WS1 DLFC 1 7 gpm for 3 4 V3162 022 WS1 DLFC 2 2 gpm for 3 4 V3162 027 WS1 DLFC 2 7 gpm for 3 4 V3162 032 WS1 DLFC 3 2 gpm for 3 4 V3162 042 WS1 DLFC 4 2 gpm for 3 4 V...

Страница 23: ...DLFC MUST BE USED IF 1 FITTING IS USED V3190 100 WS1 DLFC 10 0 GPM FOR 1 V3190 110 WS1 DLFC 11 0 GPM FOR 1 V3190 130 WS1 DLFC 13 0 GPM FOR 1 V3190 150 WS1 DLFC 15 0 GPM FOR 1 V3190 170 WS1 DLFC 17 0...

Страница 24: ...9BSPT V3080 V3080BSPT 1 V3081 WS15 RETAINER DLFC ASY 1 1 1 1 2 V3645 WS15 DLFC FLANGE OUTLET FNPT 1 1 V3645BSPT WS15 DLFC FLANGE OUTLET FBSPT 1 1 3 V3646 WS15 DLFC FLANGE INLET MNPT 1 1 4 V3388 WS125...

Страница 25: ...5 WS1 DLFC 7 5 gpm for 3 4 V3162 090 WS1 DLFC 9 0 gpm for 3 4 V3162 100 WS1 DLFC 10 0 gpm for 3 4 V3190 090 WS1 DLFC 9 0 gpm for 1 V3190 100 WS1 DLFC 10 0 gpm for 1 V3190 110 WS1 DLFC 11 0 gpm for 1 V...

Страница 26: ...B indicates BSPT N indicates NPT 2 4 1 3 1 6 6 5 Assemblies are shipped without drain line flow control DLFC washers Assembly instructions 1 Determine the desired flow rate Select a combination of V3...

Страница 27: ...AR PLAIN 3 6 V3264 WS2 BYPASS REDUCTION GEAR AXLE 3 7 V3292 WS2 SCREW BSHD SS 1 4 20X1 1 2 4 8 V3059 WS1 5 2ALT 2BYPAS AUTODRIVEASY 1 9 V3298 01 WS2 ALT VALVE BODY NPT 1 V3298BSPT 01 WS2 ALT VALVE BOD...

Страница 28: ...DRIVE ASY 1 1 9 V3634 01 MAV NOHWBY 2 PISTON 1 1 10 V3077 MAV NOHWBY 2 STACK ASY 1 1 11 V3633 01 WS2 MAV BODY NPT 1 N A V3633 01BSPT WS2 MAV BODY BSPT N A 1 Not Shown V3474 WS ALT CONNECT CORD 8FT BL...

Страница 29: ...20 X 1 1 4 BHSCS SS 5 32 HEX ALLEN WRENCH REQUIRED 4 4 8 V3078 MAV NOHWBY 2 DRIVE ASY 1 1 9 V3634 01 MAV NOHWBY 2 PISTON 1 1 10 V3887 WS2 NHWBY STACK ASY 1 1 11 V3828 01 WS2 NHWBY BODY M X F NPT 1 N A...

Страница 30: ...TACK ASY 1 1 11 V3693 01 WS3 MAV BODY NPT 1 N A V3693BSPT 01 WS3 MAV BODY BSPT N A 1 Sold Separately V3475 12 WS2H WS3 SYSTEM CONNECTION CORD 12 FOOT RED One must be used for twin tank operation V3475...

Страница 31: ...rder No Description Quantity V3099 V3099BSPT 1 V3696 WS3 MAV COVER 1 1 2 V3476 WS MOTOR ASY 8 FT 1 1 3 V3592 SCREW 8 1 PHPN T 25 SS 3 3 4 V3262 01 WS 1 5 2ALT 2BY REDUCGEARCVRASY 1 1 5 V3110 01 WS1 DR...

Страница 32: ...SS BODY ASY NPT 1 1 V3057BSPT WS2H BYPASS BODY ASY BSPT Not Shown V3053 WS2H 2 1 2 GROOVELOCK CLAMP ASY 2 2 V3060 WS2H BYPASS AUTO NPT V3060BSPT WS2H BYPASS AUTO BSPT V3061BSPT WS2H BYPASS MANUAL BSPT...

Страница 33: ...MPASY Drawing No Order No Description Quantity 1 V3053 WS2 2 1 2 GROOVELOCK CLAMP ASY 1 2 V3290 WS2 GROOVE LOCK SEAL 2 5 1 3 V3269 WS2H NUT 5 16 18 SS HEX 1 4 V3293 WS2H WASHER SS 5 16 FLAT 1 5 V3276...

Страница 34: ...ypass Drive Could Not Drive Offline 15011 Run Time To Short Bypass Drive Could Not Drive Online 16001 Communication Lost With Unit 2 16002 Communication Lost With Unit 3 16003 Communication Lost With...

Страница 35: ...does not indicate that water is flowing Refer to user instructions for how the display indicates water is flowing a Bypass isolation valve in bypass position b Meter is not connected to meter connecti...

Страница 36: ...usted water quality is poor a Higher than anticipated water usage b Meter not registering c No regenerant or low level of regenerant in regenerant tank d Control fails to draw in regenerant e Water qu...

Страница 37: ...al inspection measure volume output into container 2 See Troubleshooting Guide 12 12 Control valve fails to draw in regenerant a Injector is plugged b Faulty regenerant piston c Regenerant line connec...

Страница 38: ...ean or replace PC Board 16 Err 1002 Control valve motor ran too short and was unable to find the next cycle position and stalled a Foreign material is lodged in control valve b Mechanical binding c Ma...

Страница 39: ...software with piston position 19 Err 15003 Motorized Bypass or MAV for NHBP valve motor ran too long and unable to find the proper park position Motorized Alternating Valve MAV No Hard Water Bypass N...

Страница 40: ...or MAV for NHBP black drive pinion on motor Press NEXT and REGEN buttons for about 3 seconds to resynchronize software with piston position 21 Err 15011 Motorized Bypass or MAV for NHBP valve motor r...

Страница 41: ...with piston position c Press NEXT and REGEN buttons for about 3 seconds to resynchronize software with piston position Then re program each valve to operate as single individual unit Re program the co...

Страница 42: ...ion gears drive gear interface and check MAV for separate source black drive pinion on motor Press NEXT and REGEN buttons for about 3 seconds to resynchronize software with piston position 25 Err 1800...

Страница 43: ...otal Slow Rinse Draw 0 1 2 3 4 20 40 60 80 100 120 Pressure psi Flow Rate gpm Order No V3010 2C US Units Total Slow Rinse Draw 0 1 2 3 4 5 6 7 20 40 60 80 100 120 Pressure psi Flow Rate gpm Order No V...

Страница 44: ...ric Units Total Slow Rinse Draw 0 10 20 30 40 50 60 100 200 300 400 500 600 700 800 900 Pressure kPa Flow Rate lpm Order No V3010 2A Metric Units Total Slow Rinse Draw 0 2 4 6 8 10 12 14 16 100 200 30...

Страница 45: ...WS2H and WS3 Drawings and Service Manual Page 45...

Страница 46: ...Page 46 WS2H and WS3 Drawings and Service Manual...

Страница 47: ...5 V3110 01 WS1 DRIVE REDUCING GEAR PLAIN 3 PAGE 31 5 V3110 01 WS1 DRIVE REDUCING GEAR PLAIN 3 PAGE 32 5 V3110 01 WS1 DRIVE REDUCING GEAR PLAIN 3 9 18 2015 PAGE 19 WHEN INSTALLING THE METER MAKE SURE T...

Страница 48: ...Page 48 WS2H and WS3 Drawings and Service Manual Form No V3215 9 13 2016 U S Patents 6 402 944 6 444 127 6 776 901...

Отзывы: