Page 18
WS1CC & WS1.25CC Manual
8
Reserve capacity estimate is based on history of water usage.
Table 8
Softener Setting Options
Gallons
Capacity
Regeneration
Time Option
Day
Override
Result
8
AUTO
NORMAL
oFF
Reserve capacity automatically estimated.
Regeneration occurs when gallons capacity falls below the reserve
capacity at the next Regen Set Time.
AUTO
NORMAL
Any
number
Reserve capacity automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity
falls below the reserve capacity or the specifi ed number of days between
regenerations is reached.
Any
number
NORMAL
oFF
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity
reaches 0.
oFF
NORMAL
Any
number
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when the specifi ed
number of days between regenerations is reached.
Any
number
NORMAL
Any
number
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity
reaches 0 or the specifi ed number of days between regenerations is
reached.
AUTO
On O
oFF
Reserve capacity not automatically estimated.
Regeneration occurs immediately when gallons capacity reaches 0.
Time of regeneration will not be allowed to be set because regeneration
will always occur when gallons capacity reaches 0.
Any
number
On O
oFF
Reserve capacity not automatically estimated.
Regeneration occurs immediately when gallons capacity reaches 0.
Time of regeneration will not be allowed to be set because regeneration
will always occur on 0.
AUTO
NORMAL on 0
oFF
Reserve capacity automatically estimated.
Regeneration occurs when gallons capacity falls below the reserve
capacity at the next Regen Set Time or regeneration occurs immediately
after 10 minutes of no water usage when gallon capacity reaches 0.
AUTO
NORMAL on 0
Any
number
Reserve capacity automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity
falls below the reserve capacity or the specifi ed number of days between
regenerations is reached or regeneration occurs immediately after 10
minutes of no water usage when gallon capacity reaches 0.
Any
number
NORMAL on 0
Any
number
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when the specifi ed
number of days between regenerations is reached or regeneration occurs
immediately after 10 minutes of no water usage when gallon capacity
reaches 0.
Содержание WS1CC
Страница 2: ......
Страница 13: ...WS1CC WS1 25CC Manual Page 13 Figure 3 Figure 4 Figure 1 Figure 2...
Страница 29: ...WS1CC WS1 25CC Manual Page 29 Drawings and Part Numbers...
Страница 41: ...WS1CC WS1 25CC Manual Page 41 Flow Diagrams Service and Backwash...
Страница 42: ...Page 42 WS1CC WS1 25CC Manual Flow Diagrams Downflow and Upflow WS1CC Only...
Страница 43: ...WS1CC WS1 25CC Manual Page 43 Flow Diagrams Rinse and Fill...
Страница 53: ...WS1CC WS1 25CC Manual Page 53...
Страница 54: ...Page 54 WS1CC WS1 25CC Manual...
Страница 55: ...WS1CC WS1 25CC Manual Page 55...
Страница 56: ...Page 56 WS1CC WS1 25CC Manual...
Страница 57: ...WS1CC WS1 25CC Manual Page 57...
Страница 58: ...Page 58 WS1CC WS1 25CC Manual...
Страница 59: ...WS1CC WS1 25CC Manual Page 59...