Page 20
WS1CC & WS1.25CC Manual
STEP 7F
STEP 8F
➟
➟
RETURN TO
NORMAL MODE
Step 7F – Set Gallons Capacity using the
▼
or
▲
button. If value is set to:
• “oFF” regeneration will be based solely on the day override set (see Installer Display/Settings Step
3I); or
• as a number regeneration initiation will be based on the value specifi ed.
See Table 9 for more detail. Press NEXT to go to Step 8F. Press REGEN to return to previous step.
Step 8F – Set Regeneration Time Options using the
▼
or
▲
button. If value is set to:
• “NORMAL” means regeneration will occur at the preset time;
• “on 0” means regeneration will occur immediately when the gallons capacity reaches 0 (zero); or
• “ on 0” means regeneration will occur at one of the following:
— the preset time when the gallons capacity falls below the reserve or the specifi ed number of days
between regenerations is reached whichever comes fi rst;
or
— after 10 minutes of no water usage when the gallon capacity reaches 0 (zero).
See Table 9 for more detail. Press NEXT to exit OEM Filter System Setup. Press REGEN to return
to previous step.
Table 9
Filter Setting Options
Gallons
Capacity
Regeneration
Time Option
Day
Override
Result
oFF
NORMAL
Any
number
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when the specifi ed
number of days between regenerations is reached.
Any
number
NORMAL
oFF
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity
reaches 0.
Any
number
NORMAL
Any
number
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity
reaches 0 or the specifi ed number of days between regenerations is
reached.
Any
number
On O
oFF
Reserve capacity not automatically estimated.
Regeneration occurs immediately when gallons capacity reaches 0.
Time of regeneration will not be allowed to be set because regeneration
will always occur on 0.
Any
number
NORMAL on 0
Any
number
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when the specifi ed
number of days between regenerations is reached or regeneration occurs
immediately after 10 minutes of no water usage when gallon capacity
reaches 0.
Содержание WS1CC
Страница 2: ......
Страница 13: ...WS1CC WS1 25CC Manual Page 13 Figure 3 Figure 4 Figure 1 Figure 2...
Страница 29: ...WS1CC WS1 25CC Manual Page 29 Drawings and Part Numbers...
Страница 41: ...WS1CC WS1 25CC Manual Page 41 Flow Diagrams Service and Backwash...
Страница 42: ...Page 42 WS1CC WS1 25CC Manual Flow Diagrams Downflow and Upflow WS1CC Only...
Страница 43: ...WS1CC WS1 25CC Manual Page 43 Flow Diagrams Rinse and Fill...
Страница 53: ...WS1CC WS1 25CC Manual Page 53...
Страница 54: ...Page 54 WS1CC WS1 25CC Manual...
Страница 55: ...WS1CC WS1 25CC Manual Page 55...
Страница 56: ...Page 56 WS1CC WS1 25CC Manual...
Страница 57: ...WS1CC WS1 25CC Manual Page 57...
Страница 58: ...Page 58 WS1CC WS1 25CC Manual...
Страница 59: ...WS1CC WS1 25CC Manual Page 59...