Regeneration Mode
Typically a system is set to regenerate at a time of low water usage. An example of a time with low water
usage is when a household is asleep. If there is a demand for water when the system is regenerating,
untreated water will be used.
When the system begins to regenerate, the display will change to include information about the step of the regeneration process and
the time remaining for that step to be completed. The system runs through the steps automatically and will reset itself to provide
treated water when the regeneration has been completed.
Manual Regeneration
Sometimes there is a need to regenerate the system sooner than when the
system calls for it, usually referred to as manual regeneration. There may be a
period of heavy water usage because of guests or a heavy laundry day.
To initiate a manual regeneration at the preset delayed regeneration time, when
the regeneration time option is set to “NORMAL” or “ on 0”,
press and release “REGEN”. The words “REGEN TODAY” will fl ash on the
display to indicate that the system will regenerate at the preset delayed regeneration time. If you pressed the “REGEN” button in
error, pressing the button again will cancel the request. Note: If the regeneration time option is set to “on 0” there is no set delayed
regeneration time so “REGEN TODAY” will not activate if “REGEN” button is pressed.
To initiate a manual regeneration immediately, press and hold the “REGEN” button for three seconds. The system will begin to
regenerate immediately. The request cannot be cancelled.
Note: For softeners, if the brine tank does not contain salt, fi ll with salt and wait at least two hours before regenerating.
Set Time of Day
The user can also set the time of day. Time of day should only need to be set if the battery has been depleted because of extended
power outages or when daylight saving time begins or ends. If an extended power outage occurs, the time of day will fl ash on and
off which indicates the time of day should be reset. The non rechargeable battery should also be replaced.
STEP 1U – Press CLOCK.
STEP 2U - Current Time (hour): Set the hour of the day using
▼
or
▲
buttons. AM/PM toggles after 12.
Press NEXT to go to Step 3U.
STEP 3U - Current Time (minutes): Set the minutes of the day using
▼
or
▲
buttons. Press NEXT to exit
Set Time of Day. Press REGEN to return to previous step.
REGEN TODAY will
Flash if a regeneration is
expected “Tonight.”
➟
STEP 1U
STEP 2U
STEP 3U
RETURN TO NORMAL MODE
➟
Power Loss
If the power goes out the system will keep time until the battery is depleted. If an
extended power outage occurs, the time of day will fl ash on and off which indicates the
time of day should be reset and the battery replaced. The system will remember the rest.
Error Message
If the word “ERROR” and a number are alternately fl ashing on the display contact the
OEM for help. This indicates that the valve was not able to function properly.
➟
➟
Содержание WS1.25HR
Страница 2: ......
Страница 13: ...WS1HR WS1 25HR Manual Page 13 Figure 3 Figure 4 Figure 1 Figure 2...
Страница 30: ...Page 30 WS1HR WS1 25HR Manual Drawings and Part Numbers...
Страница 42: ...Page 42 WS1HR WS1 25HR Manual Flow Diagrams Service and Backwash...
Страница 43: ...WS1HR WS1 25HR Manual Page 43 Flow Diagrams Downflow and Upflow WS1HR Only...
Страница 44: ...Page 44 WS1HR WS1 25HR Manual Flow Diagrams Rinse and Fill...
Страница 54: ...Page 54 WS1HR WS1 25HR Manual...
Страница 55: ...WS1HR WS1 25HR Manual Page 55...
Страница 56: ...Page 56 WS1HR WS1 25HR Manual...
Страница 57: ...WS1HR WS1 25HR Manual Page 57...
Страница 58: ...Page 58 WS1HR WS1 25HR Manual...
Страница 59: ...WS1HR WS1 25HR Manual Page 59...