WS1CC & WS1.25CC Manual
Page 21
STEP 1I - Press NEXT and
▲
simultaneously for 3 seconds.
STEP 2I – Hardness: Set the amount of hardness in grains of hardness as calcium carbonate per gallon
using the
▼
or
▲
buttons. The default is 20 with value ranges from 1 to 150 in 1 grain increments. Note:
The grains per gallon can be increased if soluble iron needs to be reduced. This display will show “–nA–”
if “FILTER” is selected in Step 2F or if ‘AUTO’ is not selected in Set Gallons Capacity in OEM Softener
System Setup. Press NEXT to go to step 3I. Press REGEN to exit Installer Display Settings.
STEP 3I – Day Override: When gallon capacity is set to off, sets the number of days between
regenerations. When gallon capacity is set to AUTO or to a number, sets the maximum number of days
between regenerations. If value set to “oFF” regeneration initiation is based solely on gallons used. If
value is set as a number (allowable range from 1 to 28) a regeneration initiation will be called for on that
day even if suffi cient number of gallons were not used to call for a regeneration. Set Day Override using
▼
or
▲
buttons:
• number of days between regeneration (1 to 28); or
• “oFF”.
See Table 8 for more detail on softener setup and Table 9 for more detail on fi lter setup. Press NEXT to go
to step 4I. Press REGEN to return to previous step.
STEP 4I – Next Regeneration Time (hour): Set the hour of day for regeneration using
▼
or
▲
buttons.
AM/PM toggles after 12. The default time is 2:00 a.m. This display will show “REGEN on 0 GAL” if “on
0” is selected in Set Regeneration Time Option in OEM Softener System Setup or OEM Filter System
Setup. Press NEXT to go to step 5I. Press REGEN to return to previous step.
STEP 5I – Next Regeneration Time (minutes): Set the minutes of day for regeneration using
▼
or
▲
buttons. This display will not be shown if “on 0” is selected in Set Regeneration Time Option in OEM
Softener System Setup or OEM Filter System Setup. Press NEXT to exit Installer Display Settings. Press
REGEN to return to previous step.
To initiate a manual regeneration immediately, press and hold the “REGEN” button for three seconds.
The system will begin to regenerate immediately. The control valve may be stepped through the various
regeneration cycles by pressing the “REGEN” button.
STEP 1I
➟
STEP 2I
STEP 3I
➟
➟
RETURN TO
NORMAL MODE
Installer Display Settings
STEP 4I
➟
STEP 5I
➟
Содержание WS1.25CC
Страница 2: ......
Страница 13: ...WS1CC WS1 25CC Manual Page 13 Figure 3 Figure 4 Figure 1 Figure 2...
Страница 29: ...WS1CC WS1 25CC Manual Page 29 Drawings and Part Numbers...
Страница 41: ...WS1CC WS1 25CC Manual Page 41 Flow Diagrams Service and Backwash...
Страница 42: ...Page 42 WS1CC WS1 25CC Manual Flow Diagrams Downflow and Upflow WS1CC Only...
Страница 43: ...WS1CC WS1 25CC Manual Page 43 Flow Diagrams Rinse and Fill...
Страница 53: ...WS1CC WS1 25CC Manual Page 53...
Страница 54: ...Page 54 WS1CC WS1 25CC Manual...
Страница 55: ...WS1CC WS1 25CC Manual Page 55...
Страница 56: ...Page 56 WS1CC WS1 25CC Manual...
Страница 57: ...WS1CC WS1 25CC Manual Page 57...
Страница 58: ...Page 58 WS1CC WS1 25CC Manual...
Страница 59: ...WS1CC WS1 25CC Manual Page 59...