6
Service/OEM SOFTENING Screens
Accessed by pressing and holding
NEXT
and
–
simultaneously for three seconds.
Returns to general display after five minutes of inactivity.
Set fourth cycle position with + or — buttons
Turn chlorine generator ON or OFF or change amount of chlorine to be generated by pressing and holding
the CLOCK and + buttons simultaneously. Press the + and – buttons to change to LOW, HIGH, or OFF.
Default setting is MEDIUM.
HIGH setting is used when additional chlorine production is necessary, such as in larger units.
Consult manufacturer before changing.
WARNING: If resin media is used, this setting MUST be set to OFF or LOW.
Set draw time with + or — buttons
Default setting is 90:00 minutes.
Set fifth cycle position with + or — buttons
Set final rapid rinse time with + or — buttons
Default setting is 4:00 minutes
Set end cycle with + or — buttons
Up to fourteen cycle positions may be programmed into a regeneration.
An END position triggers the end of a regeneration and a return to service.
CYCLE 4
REGENERANT DRAW DN
SET
90:00
MIN
DRAW TIME
SET
CYCLE 5
RINSE
SET
4:00
MIN
RINSE TIME
SET
CYCLE 6
END
SET
11
12
14
MEDIUM
GENERATE CHLORINE
13
15
16
continued from
previous page
return to general display
Содержание Sanitizer Plus
Страница 1: ...Master Programming Manual for Sanitizer Plus Models Effective February 2019...
Страница 13: ...13 Notes...
Страница 14: ...14 Notes...
Страница 15: ...15 Notes...
Страница 16: ...1900 Prospect Court Appleton WI 54914 Phone 920 739 9401 Fax 920 739 9406 MAN SAN PL MAST Rev A0219...