Installing the water heater.
5
The location chosen for the water heater must take into consideration the following:
Local Installation Regulations
This water heater must be installed in
accordance with these instructions, local
codes, utility codes, utility company
requirements or, in the absence of local
codes, the latest edition of the National
Electrical Code. It is available from some
local libraries or can be purchased from
the National Fire Protection Association,
Batterymarch Park, Quincy, MA 02269 as
booklet ANSI/NFPA 70.
If the water heater is to be installed in a
restaurant, or other location where NSF
International listing is required, it must
be weather sealed to the floor, a raised
base, or on a shelf so that seepage cannot
accumulate under it; or elevated to provide
at least (6) inches of clearance from the
floor.
In order to meet NSF International
requirements for Standard 5, the base
of the water heater must be sealed to
the floor to prevent seepage underneath.
Apply a 3/8" bead of RTV Silicone
completely around the floor edge of the
base of the tank.
Location
Locate the water heater in a clean dry area
as near as practical to the area of greatest
heated water demand. Long un-insulated
hot water lines can waste energy and
water.
Place the water heater in such a manner
that the thermostat and element access
panels can be removed to permit inspection
and servicing such as removal of elements
or checking controls.
The water heater and water lines should
be protected from freezing temperatures.
Do not install the water heater in outdoor,
unprotected areas or near any other
appliances where high temperatures are
present, such as wood burning stoves,
boilers, or furnaces. High temperatures
can warp or otherwise damage the non-
metallic construction of this water heater.
Make certain the floor underneath
the water heater is strong enough to
sufficiently support the weight of the
water heater once it is filled with water.
Unit
Capacity
(Gallons)
Unit
Capacity
(Imperial Gallons)
Dimensions (Inches)
Height
1
Diameter
Shipping
Weight
(lbs)
Approximate
Full Weight
(lbs)
15
13
35 5/8
21 5/8
58
183
20
17
34 1/2
23 1/2
61
228
30
25
53
21 5/8
75
325
40
33
65 1/2
21 5/8
90
424
50
42
66 3/4
23 1/2
100
517
50S
47 1/4
28 1/4
95
512
75
63
62 5/8
28 1/4
122
748
85
71
70 1/4
28 1/4
134
843
105
88
70 3/4
30 1/4
152
1,028
1
Height includes factory installed Temperature and Pressure Relief Valve.
NOTICE: DO NOT use
fittings on top of the unit as
handles or lift points.