Water Heater Innovations 15 Скачать руководство пользователя страница 16

Vacation and Extended Shut-Down

If the water heater is to remain idle for an 

extended period of time, the power and 

water to the appliance should be turned off 

to conserve energy.
If the water heater is installed in a 

location where it could freeze when not 

operational, all water must be drained 

from the unit and piping  If the tank is full 

of water and freezes, the tank will break.  

See the "Draining the Water Heater" 

section for details on draining the unit.  

Freeze damage is not covered under the 

manufacturer's warranty.
After a long shut-down period, the 

water heater’s operation and controls 

should be checked by qualified service 

personnel.  Make certain the water heater 

is completely filled again before placing it 

in operation.

Care and cleaning of the water heater.

Draining the Water Heater

Routine Preventative Maintenance

Properly maintained, your water heater 

will provide years of dependable trouble-

free service. 
It is suggested that a routine preventive 

maintenance program be established and 

followed by the user. 
It is further recommended that a periodic 

inspection of the operating controls, 

heating elements and wiring should be 

made by service personnel qualified in 

electric appliance repair.
Most electrical appliances, even when 

new, make some sound when in operation. 

If the hissing or singing sound level 

increases excessively, the electric heating 

element may require cleaning. Contact a 

qualified installer or plumbing contract to 

inspect.
At least once a year, lift and release the 

lever handle on the temperature pressure 

relief valve, located near the top of the 

water heater, to make certain the valve 

operates freely. Allow several gallons to 

flush through the discharge line to an open 

drain.
A water heater’s tank can act as a settling 

basin for solids suspended in the water.  It 

is therefore not uncommon for hard water 

deposits to accumulate in the bottom of 

the tank. It is suggested that a few quarts/

liters of water be drained from the water 

heater’s tank every month to clean the tank 

of these deposits.
Rapid closing of faucets or solenoid 

valves in automatic water using appliances 

can cause a banging noise heard in a 

water pipe. Strategically located risers in 

the water pipe system or water hammer 

arresting devices can be used to minimize 

the problem.

DANGER: Before 

manually operating the relief 

valve, make certain no one will 

be exposed to the danger of 

coming in contact with the hot 

water released by the valve. 

The water may be hot enough 

to create a scald hazard. The 

water should be released into a 

suitable drain to prevent 

injury or property damage.

 

NOTICE: If the temperature 

and pressure relief valve 

on the hot water heater 

discharges periodically, 

this may be due to thermal 

expansion in a closed water 

system. Contact the water 

supplier or your plumbing 

contractor on how to correct 

this. Do not plug the relief 

valve outlet. 

16

   Shut off power to the water heater.

    Open a hot water faucet nearest the 

water heater.  Run water until cold.

    Turn off the cold water supply to 

the water heater.

   Leave the hot water faucet open.

    Attach a garden hose to the drain 

valve on the bottom of the water 

heater and direct the hose to a 

drain.

    Lift open the handle on the relief 

valve, and leave open.  (top center 

fitting on water heater) (some 

water may be released)

   Open the drain valve.

   Drain water heater completely.
   Close the drain valve.

   Close the relief valve.

NOTICE: Additional instructions for 

draining the unit are located on the 

water heater.

Please reference the "To Fill the 

Water Heater" section (see page 8) for 

instructions on how to refill the unit.

Содержание 15

Страница 1: ...ctions or any terms within it seek professional advice Any questions regarding the operation maintenance service or warranty of this water heater should be directed to the seller from whom it was purc...

Страница 2: ...of your water heater You ll find many answers to common problems in the Before You Call For Service section If you review our chart of Troubleshooting Tips first you may not need to call for service...

Страница 3: ...this manual for detailed instructions in how to adjust the thermostat s DANGER Hotter water increases the potential for Hot Water SCALDS D A N G E R HOT Water temperature over 125 F can cause severe b...

Страница 4: ...Office of the State Architect 1102 Q Street Suite 5100 Sacramento CA 95811 or you may call 916 445 8100 or ask a water heater dealer However applicable local codes shall govern installation For reside...

Страница 5: ...ctical to the area of greatest heated water demand Long un insulated hot water lines can waste energy and water Place the water heater in such a manner that the thermostat and element access panels ca...

Страница 6: ...e water heater and system piping This rapid pressure increase can quickly reach the safety setting of the relief valve causing it to operate during each heating cycle Thermal expansion and the resulti...

Страница 7: ...approved for hot water distribution The discharge line must be no smaller than the outlet of the valve and must pitch downward from the valve to allow complete drainage by gravity of the relief valve...

Страница 8: ...id damaging the unit WARNING Failure to follow the instructions provided in this manual may permanently damage the unit and void the manufacturer s warranty NOTICE Do not attempt to turn any fitting c...

Страница 9: ...using metal strapping or wire fastened to the structure overhead Seal Ring Inside nut Hex Union Nut Relief Valve No threads permitted on end of Drain Pipe 6 Maximum distance from drain pipe to suitabl...

Страница 10: ...he water heater The branch circuit wiring should include either Metallic conduit or metallic sheathed cable approved for use as a grounding conductor and installed with fittings approved for the purpo...

Страница 11: ...eAWG Based on N E C Table 310 16 75 C 120V 240V 120V 240V 2 000 20 12 3 000 20 12 3 800 20 12 4 500 25 10 11 Wiring Diagrams SINGLE ELEMENT 2 1 2 THERMOSTAT HIGH TEMP LIMIT ECO HEATING ELEMENT WHITE Y...

Страница 12: ...The use of unauthorized energy saving devices may shorten the life of the water heater and may endanger life and property The manufacturer disclaims any responsibility for such loss or injury resulti...

Страница 13: ...room to service heater Water heater completely filled with water Air purged from water heater and piping Water connections tight and free of leaks Temperature and Pressure Relief Valve properly instal...

Страница 14: ...in until it has been thoroughly checked by qualified service personnel DANGER There is a hot water scald potential if the thermostat is set too high Households with small children disabled or elderly...

Страница 15: ...ion pads The thermostat protective cover should not be removed Using a small screwdriver set the thermostat dial pointer to the desired temperature by turning the screw Do not pry or move the white pl...

Страница 16: ...rge line to an open drain A water heater s tank can act as a settling basin for solids suspended in the water It is therefore not uncommon for hard water deposits to accumulate in the bottom of the ta...

Страница 17: ...ke sure electric supply to water heater and disconnect switch if used are in the ON position The thermostat may be set too low See the Temperature regulation of the water heater section of this manual...

Страница 18: ...crew 8 16 x 5 8 12 Upper Thermostat 13 Upper Protector 14 Screw 10 16 x 5 8 15 Thermostat Cavity Insulation 16 Upper Access Panel 17 Screw 10 16 x 5 8 18 Access Panel Cover Insulation 19 Access Panel...

Страница 19: ...19 Replacement Parts 30 105 gallon models 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 19 18 17 24 15 14 23 22 25 20 26 7 3...

Страница 20: ...Replacement Parts 15 20 gallon models 20...

Страница 21: ...available for purchase through your water heater distributor NOTICE Make sure the threads on the unit are clean Brush debris off of threads with a toothbrush if needed NOTICE The elements are unique t...

Страница 22: ...resulting from improper installation or failure to operate and maintain the water heater in accordance with the manufac turer s instructions provided d Performance problems caused by improper sizing o...

Страница 23: ...ent regulations or industry certification or similar standards require the replacement water heater or replacement component part s to have features not found in the defective water heater or the defe...

Страница 24: ...er Information Name Address Plumber Mechanical Contractor Installer Information Name Address Telephone Number Water Heater Information Model Number Serial Number Date of Installation FOR YOUR RECORDS...