background image

For increased energy efficiency, some 

water heaters have been supplied with 

two 24” sections of pipe insulation. 

Please install the insulation, according 

to the illustrations above, that best meets 

your requirements.

Typical vertical piping arrangement

Typical horizontal piping arrangement

Hot and Cold Pipe Insulation Installation

Insulation blankets, available to the 

general public, for external use on electric 

water heaters are not necessary.  The 

purpose of an insulation blanket is to 

reduce the standby heat loss encountered 

with storage tank heaters.  This water 

heater meets or exceeds the National 

Appliance Energy Conservation Act 

standards with respect to insulation and 

standby loss requirements making an 

insulation blanket unnecessary. 
The manufacturer’s warranty does not 

cover any damage or defect caused by 

installation, attachment or use of  

any type of energy saving or other 

unapproved devices (other than those 

authorized by the manufacturer) into, onto 

or in conjunction with the water heater. 

The use of unauthorized energy saving 

devices may shorten the life of the water 

heater and may endanger life and property.
The manufacturer disclaims any 

responsibility for such loss or injury 

resulting from the use of such 

unauthorized devices.

!

CAUTION: If local codes require the 

application of an external insulation 

blanket to this water heater, pay careful 

attention to the following so as not to 

restrict the proper function and 

operation of the water heater:

  Do not cover the operating or warning 

labels attached to the water heater or 

attempt to relocate them on the exterior 

of insulation blanket.

  Do not apply insulation to the top of 

the water heater.  This could interfere 

with the safe operation of the electrical 

junction box.

  Do not cover the jacket access panel(s) 

to the thermostat(s) and heating 

element(s), vacuum valve, or pressure 

and temperature relief valve.

  Inspect the insulation blanket frequently.

!

WARNING: If local 

codes require external 

application of insulation 

blanket kits the 

manufacturer’s instructions 

included with the kit must 

be carefully followed.

Insulation Blankets

12

Installing the water heater.

Notice: 

Do not

 cover or 

block opening on vacuum 

valve

Vacuum 

Valve

Vacuum 

Valve

Содержание 15

Страница 1: ...ctions or any terms within it seek professional advice Any questions regarding the operation maintenance service or warranty of this water heater should be directed to the seller from whom it was purc...

Страница 2: ...of your water heater You ll find many answers to common problems in the Before You Call For Service section If you review our chart of Troubleshooting Tips first you may not need to call for service...

Страница 3: ...this manual for detailed instructions in how to adjust the thermostat s DANGER Hotter water increases the potential for Hot Water SCALDS D A N G E R HOT Water temperature over 125 F can cause severe b...

Страница 4: ...Office of the State Architect 1102 Q Street Suite 5100 Sacramento CA 95811 or you may call 916 445 8100 or ask a water heater dealer However applicable local codes shall govern installation For reside...

Страница 5: ...ctical to the area of greatest heated water demand Long un insulated hot water lines can waste energy and water Place the water heater in such a manner that the thermostat and element access panels ca...

Страница 6: ...e water heater and system piping This rapid pressure increase can quickly reach the safety setting of the relief valve causing it to operate during each heating cycle Thermal expansion and the resulti...

Страница 7: ...approved for hot water distribution The discharge line must be no smaller than the outlet of the valve and must pitch downward from the valve to allow complete drainage by gravity of the relief valve...

Страница 8: ...id damaging the unit WARNING Failure to follow the instructions provided in this manual may permanently damage the unit and void the manufacturer s warranty NOTICE Do not attempt to turn any fitting c...

Страница 9: ...using metal strapping or wire fastened to the structure overhead Seal Ring Inside nut Hex Union Nut Relief Valve No threads permitted on end of Drain Pipe 6 Maximum distance from drain pipe to suitabl...

Страница 10: ...he water heater The branch circuit wiring should include either Metallic conduit or metallic sheathed cable approved for use as a grounding conductor and installed with fittings approved for the purpo...

Страница 11: ...eAWG Based on N E C Table 310 16 75 C 120V 240V 120V 240V 2 000 20 12 3 000 20 12 3 800 20 12 4 500 25 10 11 Wiring Diagrams SINGLE ELEMENT 2 1 2 THERMOSTAT HIGH TEMP LIMIT ECO HEATING ELEMENT WHITE Y...

Страница 12: ...The use of unauthorized energy saving devices may shorten the life of the water heater and may endanger life and property The manufacturer disclaims any responsibility for such loss or injury resulti...

Страница 13: ...room to service heater Water heater completely filled with water Air purged from water heater and piping Water connections tight and free of leaks Temperature and Pressure Relief Valve properly instal...

Страница 14: ...in until it has been thoroughly checked by qualified service personnel DANGER There is a hot water scald potential if the thermostat is set too high Households with small children disabled or elderly...

Страница 15: ...ion pads The thermostat protective cover should not be removed Using a small screwdriver set the thermostat dial pointer to the desired temperature by turning the screw Do not pry or move the white pl...

Страница 16: ...rge line to an open drain A water heater s tank can act as a settling basin for solids suspended in the water It is therefore not uncommon for hard water deposits to accumulate in the bottom of the ta...

Страница 17: ...ke sure electric supply to water heater and disconnect switch if used are in the ON position The thermostat may be set too low See the Temperature regulation of the water heater section of this manual...

Страница 18: ...crew 8 16 x 5 8 12 Upper Thermostat 13 Upper Protector 14 Screw 10 16 x 5 8 15 Thermostat Cavity Insulation 16 Upper Access Panel 17 Screw 10 16 x 5 8 18 Access Panel Cover Insulation 19 Access Panel...

Страница 19: ...19 Replacement Parts 30 105 gallon models 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 19 18 17 24 15 14 23 22 25 20 26 7 3...

Страница 20: ...Replacement Parts 15 20 gallon models 20...

Страница 21: ...available for purchase through your water heater distributor NOTICE Make sure the threads on the unit are clean Brush debris off of threads with a toothbrush if needed NOTICE The elements are unique t...

Страница 22: ...resulting from improper installation or failure to operate and maintain the water heater in accordance with the manufac turer s instructions provided d Performance problems caused by improper sizing o...

Страница 23: ...ent regulations or industry certification or similar standards require the replacement water heater or replacement component part s to have features not found in the defective water heater or the defe...

Страница 24: ...er Information Name Address Plumber Mechanical Contractor Installer Information Name Address Telephone Number Water Heater Information Model Number Serial Number Date of Installation FOR YOUR RECORDS...

Отзывы: