mounted. 2.
The
tap
is
broken or tap silica gel
falls off.
2. Replace the tap.
3
Hot water is not hot
1. 96
•
bimetallic thermostat acts
•
2. Heating wire has poor contact or
is damaged.
1. wait for 5
•
10 minute
•
the
thermostat will
self-reset
•
2. Inspect or replace the hot tank.
4
Cold water is not cold
Cooling system is damaged or aging.
Inspect the system or replace its
components. See Attachment 3.
5
Water leakage at the
tap.
The tap is broken
Replace the tap.
6
Water leakage inside
the machine.
1. The sealing ring of cold tank
becomes loose
2. The inside pipeline becomes
loose or damaged
1
•
Open the upper cover and fix
the sealing ring
2
•
Inspect or replace the inside
silica gel tube.
VI. Cautions
1. Wait for 5-10 minute after the 96
•
bimetallic thermostat acts. It will self-reset. If multiple false
prevention actions happen to the same machine, confirm whether the 96
•
bimetallic thermostat
causes greater errors. It is required to replace the manual reset temperature controller.
2. In case water leakage, failure to reset or component rupture happen to the tap, replace the entire
tap, without repairing it.
3. In maintenance or cleaning, be sure not to pull the
sealing ring
off the cold tank. If it gets loose,
repair it in due course.