background image

 

mounted. 2. 

The 

tap 

is 

broken or tap silica gel 

falls off. 

2.  Replace the tap. 

Hot water is not hot 

1.  96

  bimetallic thermostat acts

 

2.  Heating wire has poor contact or 

is damaged.   

1. wait for 5

10 minute

the 

thermostat will 

self-reset

 

2.  Inspect or replace the hot tank. 

Cold water is not cold 

Cooling system is damaged or aging. 

 

 

Inspect the system or replace its 

components. See Attachment 3. 

Water leakage at the 

tap. 

The tap is broken 

Replace the tap. 

Water leakage inside 

the machine. 

1.  The sealing ring of cold tank 

becomes loose 

2.  The inside pipeline becomes 

loose or damaged 

1

  Open the upper cover and fix 

the sealing ring 

2

  Inspect or replace the inside 

silica gel tube.   

 

VI. Cautions

 

 

 

 

1.  Wait for 5-10 minute after the 96

  bimetallic thermostat acts. It will self-reset. If multiple false 

prevention actions happen to the same machine, confirm whether the 96

 bimetallic thermostat 

causes greater errors. It is required to replace the manual reset temperature controller. 

2.  In case water leakage, failure to reset or component rupture happen to the tap, replace the entire 

tap, without repairing it. 

3.  In maintenance or cleaning, be sure not to pull the 

sealing ring

 off the cold tank. If it gets loose, 

repair it in due course. 

 

 

 

                             

Содержание DLC-100R

Страница 1: ...DLC 100R WATER DISPENSER SERVICE MANUAL Prepared By Water Dispenser Development Dept NOV 2004 S N DLC100R001...

Страница 2: ...n Components and Their Functions 1 4 List of Universal and Wear Parts 2 5 Common Failures and Maintenance Methods 2 6 Cautions 3 7 Attachment 1 Wiring Principle Diagram 4 8 Attachment2 Exploded View 5...

Страница 3: ...l tank by using R134a as the cooling medium Under the auto control of the temperature controller keep the temperature of water and refrigerator below 10 for instant use II Main Technical Parameters Po...

Страница 4: ...eplaceable and easy cleaning IV List of Universal and Wear Parts See the exploded view in Attachment 2 Power switch 5 115V 10A plastic tumbler switch Hot tank assembly 35 115V 60Hz 420W insulation cot...

Страница 5: ...ld tank becomes loose 2 The inside pipeline becomes loose or damaged 1 Open the upper cover and fix the sealing ring 2 Inspect or replace the inside silica gel tube VI Cautions 1 Wait for 5 10 minute...

Страница 6: ...Attachment 1 Water Dispenser Wiring Principle Diagram...

Страница 7: ...Attachment 2 Water Dispenser Exploded View...

Страница 8: ...e evaporator Because the evaporator has much larger volume than that of the capillary liquid freon will absorb a great deal of heat from outside to become gas and finally returns to the compressor for...

Страница 9: ...r a multimeter If the resistance between any two windings is infinite turnoff happens 2 Winding earthing with a multimeter at low resistance level measure between the three terminals from the hermetic...

Страница 10: ...If it moves slightly that would be good and otherwise replace the compressor...

Отзывы: