52
0207
Programming
Example:
•
ON TIME 212-158
°
F (100-70
°
C) 8 seconds.
•
ON TIME 158
°
F (70
°
C) - END 13 seconds.
•
END TEMP. 113
°
F (45
°
C).
•
Wash temperature 194
°
F (90
°
C).
The following takes place:
•
When the water in the drum reaches 194-158
°
F
(90-70
°
C), the water valve is ON 8 seconds,
OFF 22 seconds, ON 8 seconds, OFF 22
seconds etc. providing the temperature in the
drum does not decrease by more than
7
°
F (4
°
C)/minute.
•
When the water in the drum is 158-113
°
F
(70-45
°
C), the water valve i ON 13 seconds,
OFF 17 seconds, ON 13 seconds, OFF 17
seconds etc.
•
When the temperature has reached 113
°
F
(45
°
C), cooling is discontinued and the next
sub-program commences.
Fast cool down
Fast cool down takes place if cool down is
selected and END TEMP is set to 0. The water
level is raised to the level set by the factory as the
high level without the cold water valve being shut
off.
Programming complete
•
When ’’END OF SEQUENCE’’ appears on the
third line of the display window and all
questions are answered, press EDIT DOWN.
•
Answer NO to the question ’’END PROG:
SESSION Y/N? if there are more sub-programs
to be answered. Answer YES if the sub-
program is the last in the completed program.
The continue under the heading ’’Looking
through the program’’.
22 sec.
22 sec.
ON
OFF
8 sec.
8 sec.
Fig.
113
111
Fig.
111
Fig.
112
…
Pulse:
0209
PROGR.MODE SELECT SEQUENCE COOL DOWN
01
ON TIME 212-158
°
F (100-70
°
C) 000 SEC.
ON TIME 158
°
F-END (70
°
C) 000 SEC.
END-TEMP 000
°
F
RED.
NER
RED.
NER
EDIT
DOWN
EDIT
DOWN
113
0208
17 sec.
17 sec.
13 sec.
13 sec.
ON
OFF
112