47
Refilling
LEVEL RESET is the value which regulates at
which level water is to be refilled if the water level
drops while a wash is in progress.
Example:
The following values are programmed:
•
Level: 130 units
•
Level reset: 10 units
This means that:
•
Water is filled to level 130 at the beginning of
the sub-program. If the water level sinks
below level 120 (130-10) during the course of
the program, the water level is refilled to level
130.
•
Select a level between 0-255. Values greater
than the level value mean that no water will be
added.
•
The recommend value is 20 units.
Temperature
The water temperature can be programmed
either in
°
C or
°
F. Use the
°
C/
°
F button to change
between scales (note that the change is not
displayed until the next change in the display
window is made).
Temperatures can be selected within the range
of 32-212
°
F (0-100
°
C) in stages of 1
°
.
Time
A sub-program can be timed in stages of 10
seconds. The longest time that can be
programmed is 41 min. 40 sec (2500 seconds).
The time does not include the time for water
filling or heating.
0190
0191
0192
Programming
95
PROGR. MODE SELECT SEQUENCE PREWASH
01
LEVEL 000 UNITS
LEVEL RESET 000 UNITS
TEMPERATURE 000
°
C
PROGR.MODE SELECT SEQUENCE PREWASH
01
LEVEL RESET 000 UNITS
TEMPERATURE 000
°
C
WASHTIME 00 MIN. 00 SEC.
PROGR.MODE SELECT SEQUENCE PREWASH
01
TEMPERATURE 000
°
C
WASHTIME 00 MIN. 00 SEC.
COLD WATER Y/N
N
RED.
NED
Number
keys
KLAR
ENTER
Press:
JA
RED.
NED
Number
keys
KLAR
ENTER
Press:
JA
RED.
NED
Number
keys
KLAR
ENTER
Press:
JA
EDIT
DOWN
or
or
EDIT
DOWN
EDIT
DOWN
or
Fig.
95
Fig.
96
Fig.
97
97
96