daily separating time for self cleaning separator [h] (usually = 23 h or 23.5 h)
t =
The flow rates recommended for the separator and the grade of fuel must not be exceeded.
The lower the flow rate the better the separation efficiency.
Sample valves must be placed before and after the separator.
6.3.4.6
MDF separator in HFO installations (1S02)
A separator for MDF is recommended also for installations operating primarily on HFO. The
MDF separator can be a smaller size dedicated MDF separator, or a stand-by HFO separator
used for MDF.
6.3.4.7
Sludge tank (1T05)
The sludge tank should be located directly beneath the separators, or as close as possible
below the separators, unless it is integrated in the separator unit. The sludge pipe must be
continuously falling.
6-16
Wärtsilä 20 Product Guide - a13 - 6 September 2016