The flow to the fresh water cooler must be calculated case by case based on how the circuit
is designed.
In case the fresh water central cooler is used for combined LT and HT water flows in a parallel
system the total flow can be calculated with the following formula:
where:
total fresh water flow [m³/h]
q =
nominal LT pump capacity[m³/h]
q
LT =
heat dissipated to HT water [kW]
Φ
=
HT water temperature after engine (91°C)
T
out
=
HT water temperature after cooler (38°C)
T
in
=
Design data:
see chapter Technical Data
Fresh water flow
see chapter Technical Data
Heat to be dissipated
max. 60 kPa (0.6 bar)
Pressure drop on fresh water side
acc. to cooler manufacturer, normally 1.2 - 1.5 x the fresh
water flow
Sea-water flow
acc. to pump head, normally 80 - 140 kPa (0.8 - 1.4 bar)
Pressure drop on sea-water side, norm.
max. 38°C
Fresh water temperature after cooler
15%
Margin (heat rate, fouling)
Wärtsilä 20 Product Guide - a13 - 6 September 2016
9-13
9. Cooling Water System
Wärtsilä 20 Product Guide
Содержание WARTSILA 20
Страница 1: ...W RTSIL 20 PRODUCT GUIDE...
Страница 34: ...This page intentionally left blank...
Страница 42: ...This page intentionally left blank...
Страница 86: ...This page intentionally left blank...
Страница 92: ...This page intentionally left blank...
Страница 124: ...This page intentionally left blank...
Страница 140: ...This page intentionally left blank...
Страница 154: ...This page intentionally left blank...
Страница 160: ...This page intentionally left blank...
Страница 172: ...This page intentionally left blank...
Страница 175: ......
Страница 176: ......
Страница 177: ......