Maximum 10 minutes if the engine is to be stopped after the idling. 3 minutes idling before
stop is recommended.
●
Maximum 6 hours if the engine is to be loaded after the idling.
Operation below 20 % load
●
Maximum 100 hours continuous operation. At intervals of 100 operating hours the engine
must be loaded to minimum 70 % of the rated output.
Operation above 20 % load
●
No restrictions.
2.3.1
Operating at low and load and idling with S.C.R. (Warstila
NOR)
When engine is coupled with a Selective Catalytic Reduction system, the following
recommendations apply:
Absolute idling (declutched main engine, disconnected generator)
●
Maximum 10 minutes if the engine is to be stopped after the idling. 3-5 minutes idling
before stop is recommended.
●
Maximum 2 hours in LFO if the engine is to be loaded after the idling. Before further
operation at idling, the engine must be loaded according to the indications reported in the
Selective Catalytic Reduction system resetting operation section.
●
Maximum 1 hour in HFO if the engine is to be loaded after the idling. Before further operation
at idling, the engine must be loaded according to the indications reported in the Selective
Catalytic Reduction system resetting operation section.
Operation below 10% MCR
●
Max continuous operation time: 6h in LFO. At intervals of 6 operating hours, the engine
must be loaded according to the indications reported in the Selective Catalytic Reduction
system resetting operation section.
●
Max continuous operation time: 3h in LFO. At intervals of 3 operating hours, the engine
must be loaded according to the indications reported in the Selective Catalytic Reduction
system resetting operation section.
Operation below 25% MCR
●
Max continuous operation time: 24h in LFO. At intervals of 24 operating hours, the engine
must be loaded according to the indications reported in the Selective Catalytic Reduction
system resetting operation section.
●
Max continuous operation time: 12h in HFO. At intervals of 12 operating hours ,the engine
must be loaded according to the indications reported in the Selective Catalytic Reduction
system resetting operation section.
Operation above 25% MCR
●
No restrictions.
Selective Catalytic Reduction system resetting operation
In case engine has to be run for prolonged time at low loads, Selective Catalytic Reduction
system resetting operation must be performed at the intervals indicated, as follows:
Engine must be loaded to minimum 70 % of the rated output for 1 hour or to minumum 50 %
of the rated output for 2 hours or alternatively engine must be loaded to minumum 25 % of
the rated output for 4 hours.
SCR resetting operation can be split into multiple operational events in case extended high
load operation is not feasible. As an example, one 1 hour engine operation at 70 % of the
2-4
DAAB605814
Wärtsilä 46F Product Guide
2. Operating Ranges
Содержание 46F Series
Страница 1: ...Wärtsilä 46F PRODUCT GUIDE ...
Страница 4: ...This page intentionally left blank ...
Страница 8: ...This page intentionally left blank ...
Страница 18: ...This page intentionally left blank ...
Страница 46: ...Fig 4 3 Cross section of the V engine 4 6 DAAB605814 Wärtsilä 46F Product Guide 4 Description of the Engine ...
Страница 86: ...This page intentionally left blank ...
Страница 104: ...This page intentionally left blank ...
Страница 154: ...This page intentionally left blank ...
Страница 162: ...This page intentionally left blank ...
Страница 170: ...This page intentionally left blank ...
Страница 176: ...This page intentionally left blank ...
Страница 194: ...This page intentionally left blank ...
Страница 200: ...This page intentionally left blank ...
Страница 202: ...This page intentionally left blank ...
Страница 207: ...Fig 21 7 List of symbols DAAF406507 7 DAAB605814 21 5 21 ANNEX Wärtsilä 46F Product Guide ...