ME
IMO Tier 2
AUX
IMO Tier 2
AUX
IMO Tier 2
DE
IMO Tier 2
DE
IMO Tier 2
Wärtsilä 16V31
750
610
750
610
720
590
750
610
720
590
RPM
kW/cyl
Engine speed
Cylinder output
176.7
181.9
180.9
181.4
180.4
g/kWh
Fuel consumption at 50% load, MDF
35.3
35.4
34.1
35.3
34.0
kg/h
Clean leak fuel quantity, MDF at 100% load
7.1
7.1
6.9
7.1
6.8
kg/h
Clean leak fuel quantity, HFO at 100% load
Lubricating oil system
420
420
420
420
420
kPa
Pressure before bearings, nom. (PT 201)
40
40
40
40
40
kPa
Suction ability main pump, including pipe loss, max.
60
60
60
60
60
kPa
Priming pressure, nom. (PT 201)
35
35
35
35
35
kPa
Suction ability priming pump, including pipe loss, max.
70
70
70
70
70
°C
Temperature before bearings, nom. (TE 201)
82
82
82
82
82
°C
Temperature after engine, approx.
223
189
182
189
182
m³/h
Pump capacity (main), engine driven
176
176
176
176
176
m³/h
Pump capacity (main), stand-by
38.0 / 38.0
38.0 / 38.0
38.0 / 38.0
38.0 / 38.0
38.0 / 38.0
m³/h
Priming pump capacity, 50Hz/60Hz
4.4
4.4
4.4
4.4
4.4
m³
Oil volume, wet sump, nom.
13.2
13.2
12.7
13.2
12.7
m³
Oil volume in separate system oil tank, nom.
0.45
0.45
0.45
0.45
0.45
g/kWh
Oil consumption (100% load), approx.
3920
3920
3920
3920
3920
l/min
Crankcase ventilation flow rate at full load
0.1
0.1
0.1
0.1
0.1
kPa
Crankcase ventilation backpressure, max.
6.0...6.8
6.0...6.8
6.0...6.8
6.0...6.8
6.0...6.8
liters
Oil volume in turning device
Cooling water system
High temperature cooling water system
373 + stat-
ic
373 + stat-
ic
373 + stat-
ic
373 + stat-
ic
373 + stat-
ic
kPa
Pressure at engine, after pump, nom. (PT 401)
600
600
600
600
600
kPa
Pressure at engine, after pump, max. (PT 401)
83
83
83
83
83
°C
Temperature before cylinders, approx. (TE 401)
96
96
96
96
96
°C
HT-water out from engine, nom (TE432)
150
150
150
150
150
m³/h
Capacity of engine driven pump, nom.
210
210
210
210
210
kPa
Pressure drop over engine, total
100
100
100
100
100
kPa
Pressure drop in external system, max.
70...150
70...150
70...150
70...150
70...150
kPa
Pressure from expansion tank
m³
Water volume in engine
Low temperature cooling water system
25 ... 38
25 ... 38
25 ... 38
25 ... 38
25 ... 38
°C
Temperature before engine (TE 451)
150
150
150
150
150
m³/h
Capacity of engine driven pump, nom.
41
41
41
41
41
kPa
Pressure drop over charge air cooler (one-stage)
110
110
110
110
110
kPa
Pressure drop over charge air cooler (two-stage)
115
115
115
115
115
kPa
Pressure drop over oil cooler
100
100
100
100
100
kPa
Pressure drop in external system, max.
3-14
Wärtsilä 31 Product Guide - a1 - 18 October 2016
Wärtsilä 31 Product Guide
3. Technical Data
Содержание 31
Страница 1: ...PRODUCT GUIDE W rtsil 31...
Страница 6: ...This page intentionally left blank...
Страница 10: ...This page intentionally left blank...
Страница 30: ...This page intentionally left blank...
Страница 36: ...This page intentionally left blank...
Страница 44: ...This page intentionally left blank...
Страница 88: ...This page intentionally left blank...
Страница 116: ...This page intentionally left blank...
Страница 134: ...This page intentionally left blank...
Страница 138: ...14 4 W rtsil 31 Product Guide a1 18 October 2016 W rtsil 31 Product Guide 14 Foundation...
Страница 140: ...14 6 W rtsil 31 Product Guide a1 18 October 2016 W rtsil 31 Product Guide 14 Foundation...
Страница 148: ...This page intentionally left blank...
Страница 150: ...This page intentionally left blank...
Страница 154: ...This page intentionally left blank...
Страница 160: ...This page intentionally left blank...
Страница 162: ...This page intentionally left blank...
Страница 165: ......
Страница 166: ......
Страница 167: ......