![Wartsila 31 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/wartsila-0/31/31_product-manual_3459283024.webp)
3.4
Wärtsilä 14V31
ME
IMO Tier 2
AUX
IMO Tier 2
AUX
IMO Tier 2
DE
IMO Tier 2
DE
IMO Tier 2
Wärtsilä 14V31
750
610
750
610
720
590
750
610
720
590
RPM
kW/cyl
Engine speed
Cylinder output
8540
8540
8260
8540
8260
kW
Engine output
3.01
3.01
3.03
3.01
3.03
MPa
Mean effective pressure
Combustion air system (Note 1)
15.11
15.11
14.56
15.11
14.56
kg/s
Flow at 100% load
45
45
45
45
45
°C
Temperature at turbocharger intake, max.
65
65
65
65
65
°C
Air temperature after air cooler (TE 601)
Exhaust gas system (Note 2)
15.54
15.54
14.98
15.54
14.98
kg/s
Flow at 100% load
13.16
13.3
12.74
13.3
12.74
kg/s
Flow at 85% load
11.34
11.9
11.48
11.9
11.48
kg/s
Flow at 75% load
7.98
9.1
8.68
9.1
8.68
kg/s
Flow at 50% load
273
273
275
273
275
°C
Temperature after turbocharger, 100% load (TE 517)
277
275
277
275
277
°C
Temperature after turbocharger, 85% load (TE 517)
295
282
284
282
284
°C
Temperature after turbocharger, 75% load (TE 517)
320
286
288
286
288
°C
Temperature after turbocharger, 50% load (TE 517)
5.0
5.0
5.0
5.0
5.0
kPa
Backpressure, max.
933
933
917
933
917
mm
Calculated pipe diameter for 35m/s
Heat balance (Note 3)
865
865
805
865
805
kW
Jacket water, HT-circuit
1620
1620
1502
1620
1502
kW
Charge air, HT-circuit
2152
2152
2092
2152
2092
kW
Charge air, LT-circuit
914
914
853
914
853
kW
Lubricating oil, LT-circuit
239
239
230
239
230
kW
Radiation
For optional engineversions heat balances may differ
Fuel system (Note 4)
1000±100
1000±100
1000±100
1000±100
1000±100
kPa
Pressure before injection pumps (PT 101)
120.0
120.0
120.0
120.0
120.0
m
3
/h
Engine driven pump capacity (MDF only)
16...24
16...24
16...24
16...24
16...24
cSt
HFO viscosity before engine
140
140
140
140
140
°C
HFO temperature before engine, max. (TE 101)
2.0
2.0
2.0
2.0
2.0
cSt
MDF viscosity, min
45
45
45
45
45
°C
MDF temperature before engine, max. (TE 101)
174.4
174.9
174.0
174.4
173.5
g/kWh
Fuel consumption at 100% load, HFO
171.6
172.0
171.1
171.6
170.6
g/kWh
Fuel consumption at 85% load, HFO
171.6
174.0
173.0
173.5
172.5
g/kWh
Fuel consumption at 75% load, HFO
178.5
183.8
182.8
183.3
182.3
g/kWh
Fuel consumption at 50% load, HFO
173.5
174.0
173.0
173.5
172.5
g/kWh
Fuel consumption at 100% load, MDF
170.6
171.1
170.1
170.6
169.7
g/kWh
Fuel consumption at 85% load, MDF
170.6
173.0
172.0
172.5
171.6
g/kWh
Fuel consumption at 75% load, MDF
3-10
Wärtsilä 31 Product Guide - a1 - 18 October 2016
Wärtsilä 31 Product Guide
3. Technical Data
Содержание 31
Страница 1: ...PRODUCT GUIDE W rtsil 31...
Страница 6: ...This page intentionally left blank...
Страница 10: ...This page intentionally left blank...
Страница 30: ...This page intentionally left blank...
Страница 36: ...This page intentionally left blank...
Страница 44: ...This page intentionally left blank...
Страница 88: ...This page intentionally left blank...
Страница 116: ...This page intentionally left blank...
Страница 134: ...This page intentionally left blank...
Страница 138: ...14 4 W rtsil 31 Product Guide a1 18 October 2016 W rtsil 31 Product Guide 14 Foundation...
Страница 140: ...14 6 W rtsil 31 Product Guide a1 18 October 2016 W rtsil 31 Product Guide 14 Foundation...
Страница 148: ...This page intentionally left blank...
Страница 150: ...This page intentionally left blank...
Страница 154: ...This page intentionally left blank...
Страница 160: ...This page intentionally left blank...
Страница 162: ...This page intentionally left blank...
Страница 165: ......
Страница 166: ......
Страница 167: ......