11
Display Page 3
Figure 5 :- In screen 3 the display shows the set
OFF TIME
in pulse mode.
5) To set the OFF TIME once again press SELECT switch to get into the OFF TIME
setting mode and use INT as an increment switch or use DEC as an decrement switch to
set the desired OFF TIME from 0.1 second minimum to 9 seconds maximum.
6) While setting the OFF TIME the OFF TIME LED will turned ON and the display will
show the set OFF TIME in screen 3 as shown in the figure 5.
7) After the setting is Complete if the Digital cold wire feeder machine is turned off all
the parameter’s which were set will be saved in the internal Microcontroller EEPROM
or the memory and will be saved until it has been changed and turned off again.
8) The setting of SPEED , ON TIME and the OFF TIME will only be saved when Digital
cold wire feeder machine is turned off will be saved until it has been changed and turned
off again.
F. Please Note : -
1) The wire from the job connector to the job is compulsory to isolate the machine from
unwanted high frequency (HF) noise.
2) The earthing to the machine through the three pin mains cord supply is compulsory
to avoid shock and to ground unwanted high frequency (HF) noise.
3) The setting of the ON TIME and the OFF TIME can be done only when the pulse
mode has been turned on.