10
D. SPEED : -
1)
Use INT
▲
as an increment switch or use DEC
▼
as an decrement switch to set the
desired speed from 0.1 meter per minute minimum to 10 meter per minute
maximum.
2)
While setting if the speed is set to 0000 the motor will turn stop and it will stop
feeding the filler wire.
3) While setting the SPEED the speed LED will turned ON and the display will show the
set SPEED in screen 1 as shown in the figure 3.
E. PULSE MODE SETTING : -
1) Pulse mode can be turned on by just pressing pulse switch. After the pulse mode has
been turned on the motor will start feeding the filler wire in pulse mode and the pulse
mode LED indicator will also turned on.
2) In pulse mode the motor indicator will start blinking indicating the status of the
motor.
Display Page 2
Figure 4 :- In screen 2 the display shows the set
ON TIME
in pulse mode.
3) The ON TIME and the OFF TIME of the motor in pulse mode can be set by turning
on the pulse mode and then pressing the SELECT switch to get into the ON TIME
setting mode and use INT as an increment switch or use DEC as an decrement switch to
set the desired ON TIME from 0.1 second minimum to 9 seconds maximum.
4) While setting the ON TIME the ON TIME LED will turned ON and the display will
show the set ON TIME in screen 2 as shown in the figure 4.