Страница 1: ...ED to ASTM 1509 04 CAN ULC S627 AND UL 1482 IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER SAVE THESE INSTRUCTIONS MODEL PS45 SERIES A Wood Energy Technical Training www wettinc ca SAFE...

Страница 2: ...Air 10 Thermostat installation 12 Operation 12 Filling the Hopper 12 Control Board 12 Fault Codes 12 General Operation 13 Thermostat Operation 13 MANUAL Mode 13 Paint Curing 13 Plated Surfaces 13 Rout...

Страница 3: ...detectors Ifyourlocalcoderequiresasmokedetectorbe installedwithinthesameroom youmustfollowtherequirements ofyourlocalcode Checkwithyourlocalbuilding firedepartment for requirements in your area THERMO...

Страница 4: ...Pressure Warning This appliance has not been designed to be operated in a negatively pressurized room Provide adequate air for combustion The stove s exhaust system works with negative combustion cham...

Страница 5: ...ape the clinkers out Clean the holes with a small pointed object if required Refer to the section Routine Cleaning and Maintenance Wood Pellet Specifications This appliance has been designed to burn w...

Страница 6: ...meets local building codes It is recommended that the unit be secured into its position in order to avoid any displacement Thisappliancemustbeinstalledonafloorwithan adequate load bearing capacity if...

Страница 7: ...rances removal of the appliance may be necessary for servicing Recommended clearance zone from the front of the appliance to combustibles is 4 feet minimum NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE...

Страница 8: ...m from the edge of the terminal E 12 inches 30 cm Clearance to unventilated soffit F 12 inches 30 cm Clearance to outside corner G 12 inches 30 cm Clearance to inside corner H 3 feet 90 cm Not to be i...

Страница 9: ...oke or odor during appliance shut down or power failure and avoid exposing people or landscaping shrubs to high temperatures Hooded vent Using existing wood vent Thru roof Recommended Recommended Reco...

Страница 10: ...without any vertical sections of pipe are approved however it is recommended that a minimum of 5 ft of vertical be included in the vent system Having a vertical section in the venting will help preven...

Страница 11: ...safely all sections of listed connector offset elbows and chimney section must be screwed to gether by at least three sheet metal screws per joint The chimney must be suitably supported by the chimney...

Страница 12: ...n requirements If the location requirements are not followed the appliance may operate erratically or failure may occur Do not mount the thermostat where it may be affected by Radiant heat from the st...

Страница 13: ...stove has run out of pellets the auger will be empty and the Burn Pot liner will need to be primed To prime place a handful of pellets into the middle of the liner On the control board push the ON OFF...

Страница 14: ...ppliance A cleaning brush can be used to loosen any ash build up before vacuuming DONOTUSEASTANDARDHOUSEHOLDVACUUM WHEN USINGA SHOPVACUUM A FINE DUST FILTER MUST BE INSTALLED AS THE STANDARD FILTERS W...

Страница 15: ...stove Vacuum out the Ash Pan enclosure before inserting the Ash Pan Fig 13 CAUTION Disposal of Ashes Ashes should be placed in a metal container with a tight fitting lid The closed container shouldbe...

Страница 16: ...n the exhaust passages fig 18 Fig 18 Don tforgettocleanuparoundtheheatexchanger Oncetheflue passage is clear of ash build up reinstall the Firebox Liner Firebox Passage Clean through here Cleaning the...

Страница 17: ...crews Cleaning the Convection Blower To clean the convection blower remove the right cabinet side see previous page Disconnect the stove power cord from the electrical outlet Using a 3 8 wrench remove...

Страница 18: ...and shuts the stove down if it senses excessive temperatures Opens at 200 F This snap switch has a reset button on it and will not allow the stove to start up until the reset button has been pushed P...

Страница 19: ...PELLET STOVES 19 PS45B 041113 24 Wiring Diagram 5050 838 A 010210 PS 45 WIRING...

Страница 20: ...5024 504 FASCO 7073 1918 21 1 5027 175 HOPPER SWITCH 22 1 5001 004 400W IGNITOR 23 1 5027 173 Pellet Vacuum Switch 24 1 5001 001 AUGER ASSEMBLY D 1 PSRP 7384 VENT STARTER TUBE ASSEMBLY 25 1 5068 7173...

Страница 21: ...PELLET STOVES 21 PS45B 041113 24 a b C D...

Страница 22: ...PELLET STOVES 22 PS45B 041113 24 a b a b A B...